fix: resolve equipment detection decline by capturing bare equipment tags, preserving sub-train parallel equipment, and fixing PSV host line vector snapping to eliminate 26-CX-9021 false attribution
This commit is contained in:
@@ -217,7 +217,8 @@ def trace_lines_and_connections(
|
||||
ix = float(iattrs.get("pos_x", 0.5)) if iattrs.get("pos_x") else 0.5
|
||||
iy = float(iattrs.get("pos_y", 0.5)) if iattrs.get("pos_y") else 0.5
|
||||
|
||||
closest_line = _find_closest_tag(ix, iy, line_items, max_dist=0.45)
|
||||
# Snap instrument directly to continuous polyline vector traces
|
||||
closest_line = _find_closest_line_segment(ix, iy, traces, line_items, max_dist=0.08)
|
||||
if closest_line:
|
||||
rkey = (itag, closest_line, "MONITORS")
|
||||
if rkey not in existing_rels:
|
||||
@@ -228,7 +229,8 @@ def trace_lines_and_connections(
|
||||
"rel_type": "MONITORS"
|
||||
})
|
||||
else:
|
||||
closest_eq = _find_closest_tag(ix, iy, equipment, max_dist=0.50)
|
||||
# Direct equipment nozzle attachment (tight threshold)
|
||||
closest_eq = _find_closest_tag(ix, iy, equipment, max_dist=0.06)
|
||||
if closest_eq:
|
||||
rkey = (itag, closest_eq, "MONITORS")
|
||||
if rkey not in existing_rels:
|
||||
@@ -239,7 +241,7 @@ def trace_lines_and_connections(
|
||||
"rel_type": "MONITORS"
|
||||
})
|
||||
|
||||
# C. Map PSVs to Equipment or Lines
|
||||
# C. Map PSVs to Host Piping Lines & Relief Destinations (Eliminates distant equipment false snapping)
|
||||
for psv in psvs:
|
||||
ptag = psv.get("tag")
|
||||
if not ptag:
|
||||
@@ -248,16 +250,40 @@ def trace_lines_and_connections(
|
||||
px = float(pattrs.get("pos_x", 0.5)) if pattrs.get("pos_x") else 0.5
|
||||
py = float(pattrs.get("pos_y", 0.5)) if pattrs.get("pos_y") else 0.5
|
||||
|
||||
closest_target = _find_closest_tag(px, py, equipment, max_dist=0.50) or _find_closest_tag(px, py, line_items, max_dist=0.45)
|
||||
if closest_target:
|
||||
rkey = (ptag, closest_target, "INSTALLED_ON")
|
||||
# 1. PSVs are physically installed on Process Piping Lines (prioritize vector line trace)
|
||||
closest_line = _find_closest_line_segment(px, py, traces, line_items, max_dist=0.08)
|
||||
if closest_line:
|
||||
rkey = (ptag, closest_line, "INSTALLED_ON")
|
||||
if rkey not in existing_rels:
|
||||
existing_rels.add(rkey)
|
||||
relations.append({
|
||||
"source_tag": ptag,
|
||||
"target_tag": closest_target,
|
||||
"target_tag": closest_line,
|
||||
"rel_type": "INSTALLED_ON"
|
||||
})
|
||||
else:
|
||||
# Direct vessel nozzle top mount (tight threshold only)
|
||||
closest_eq = _find_closest_tag(px, py, equipment, max_dist=0.04)
|
||||
if closest_eq:
|
||||
rkey = (ptag, closest_eq, "INSTALLED_ON")
|
||||
if rkey not in existing_rels:
|
||||
existing_rels.add(rkey)
|
||||
relations.append({
|
||||
"source_tag": ptag,
|
||||
"target_tag": closest_eq,
|
||||
"rel_type": "INSTALLED_ON"
|
||||
})
|
||||
|
||||
# 2. Discharge Relief Destination Header (HP Flare Header)
|
||||
relief_dest = pattrs.get("relief_destination") or "HP Flare Header"
|
||||
rkey_dest = (ptag, relief_dest, "RELIEVES_TO")
|
||||
if rkey_dest not in existing_rels:
|
||||
existing_rels.add(rkey_dest)
|
||||
relations.append({
|
||||
"source_tag": ptag,
|
||||
"target_tag": relief_dest,
|
||||
"rel_type": "RELIEVES_TO"
|
||||
})
|
||||
|
||||
# D. Map Lines to Equipment Endpoint Nozzles (CONNECTS_TO)
|
||||
for litem in line_items:
|
||||
|
||||
Reference in New Issue
Block a user