feat: implement 3-agent audit recommendations: anti-hallucination line filter, sink flow directionality, split sibling instruments, suction strainer detection, and decimal point restoration
This commit is contained in:
+32
-5
@@ -262,8 +262,21 @@ class CompilerAgent(BaseAgent):
|
||||
compiled = []
|
||||
line_tags = [t for t in texts if t["classification"] == "LINE_TAG"]
|
||||
|
||||
# Anti-hallucination & Schema Validation Tokens
|
||||
INVALID_LINE_TOKENS = {
|
||||
'NOTE', 'TIT', 'PIT', 'LIT', 'FIT', 'PDI', 'PDT', 'PT', 'TT', 'FT', 'LT',
|
||||
'REV', 'DWG', 'SHT', 'DETAIL', 'TYP', 'EL', 'M01', 'M02', 'M03', 'MOTOR'
|
||||
}
|
||||
|
||||
for lt in line_tags:
|
||||
tag = lt["tag"]
|
||||
|
||||
# ── Pre-Export Schema Validator & Anti-Hallucination Filter ────────
|
||||
# 1. Reject motor tags or electrical cable circuits (e.g., 26-KA-902-M01, TT-26-9711-AS20-00)
|
||||
tag_upper = tag.upper()
|
||||
if re.search(r'-(?:M\d{2}|C0\d)$', tag_upper) or tag_upper.startswith(('TT-', 'PT-', 'LT-', 'FT-', 'TIT-', 'PIT-', 'LIT-', 'FIT-')):
|
||||
continue
|
||||
|
||||
# Intelligently split tag and detect whether size prefix is present
|
||||
parts = [p.strip() for p in tag.split('-') if p.strip()]
|
||||
|
||||
@@ -306,6 +319,14 @@ class CompilerAgent(BaseAgent):
|
||||
spec = rem[3]
|
||||
insulation = rem[4]
|
||||
|
||||
# 2. Reject if service or spec was force-fitted with descriptive/note tokens (e.g. ...-NOTE, ...-TIT)
|
||||
if service.upper() in INVALID_LINE_TOKENS or spec.upper() in INVALID_LINE_TOKENS:
|
||||
continue
|
||||
|
||||
# 3. Reject if service code is not a clean alphabetic fluid/system descriptor
|
||||
if not re.match(r'^[A-Z]{1,4}$', service.upper()):
|
||||
continue
|
||||
|
||||
path_coords = None
|
||||
for trace in geom.get("traces", []):
|
||||
if trace["tag"] == tag:
|
||||
@@ -783,16 +804,22 @@ class CompilerAgent(BaseAgent):
|
||||
or "N/A"
|
||||
)
|
||||
|
||||
# Auto-detect relief destination from notes/service callout (e.g. FLARE / CLOSED DRAIN)
|
||||
# Auto-detect relief destination from notes/service callout (e.g. HP FLARE vs LP FLARE)
|
||||
destination = attrs.get("relief_destination")
|
||||
if not destination:
|
||||
for t in texts:
|
||||
val = t.get("value", "")
|
||||
if "FLARE" in val.upper() or "DRAIN" in val.upper():
|
||||
destination = val.strip()
|
||||
val = t.get("value", "").upper()
|
||||
if "HP FLARE" in val or "HP-FLARE" in val or "HIGH PRESSURE FLARE" in val:
|
||||
destination = "HP Flare Header"
|
||||
break
|
||||
elif "LP FLARE" in val or "LP-FLARE" in val or "LOW PRESSURE FLARE" in val:
|
||||
destination = "LP Flare Header"
|
||||
break
|
||||
elif "CLOSED DRAIN" in val or "DRAIN" in val:
|
||||
destination = "Closed Drain Header"
|
||||
break
|
||||
if not destination:
|
||||
destination = "LP Flare Header"
|
||||
destination = "HP Flare Header"
|
||||
|
||||
compiled.append(SafetyReliefValveItem(
|
||||
tag=tag,
|
||||
|
||||
@@ -333,6 +333,9 @@ def trace_lines_and_connections(
|
||||
"rel_type": "EARTHED_TO"
|
||||
})
|
||||
|
||||
# ── Engineering Flow Directionality & Sink Constraint Enforcement ─────────
|
||||
relations = _enforce_engineering_directionality(relations)
|
||||
|
||||
logger.info(
|
||||
f"line_tracer: Extracted {len(traces)} line traces & {len(relations)} topological relations."
|
||||
)
|
||||
@@ -346,6 +349,51 @@ def trace_lines_and_connections(
|
||||
}
|
||||
|
||||
|
||||
def _enforce_engineering_directionality(relations: List[Dict[str, Any]]) -> List[Dict[str, Any]]:
|
||||
"""
|
||||
Enforces process engineering topological constraints:
|
||||
1. Nodes designated as FLARE, ATMOSPHERE, DRAIN, SUMP, SEWER, VENT are terminal SINKS.
|
||||
They cannot have outgoing 'feeds' or 'connects_to' edges to process equipment/valves.
|
||||
2. Inverts inverted edges (e.g., 'LP FLARE feeds 26-CK-921' -> '26-CK-921 relieves_to LP FLARE').
|
||||
"""
|
||||
SINKS = (
|
||||
'FLARE', 'HP FLARE', 'LP FLARE', 'HP_FLARE', 'LP_FLARE',
|
||||
'DRAIN', 'CLOSED DRAIN', 'OPEN DRAIN', 'CLOSED_DRAIN', 'OPEN_DRAIN',
|
||||
'ATMOSPHERE', 'SUMP', 'SEWER', 'VENT', 'SCRAP'
|
||||
)
|
||||
corrected = []
|
||||
seen = set()
|
||||
|
||||
for r in relations:
|
||||
src = str(r.get("source_tag", "")).strip()
|
||||
tgt = str(r.get("target_tag", "")).strip()
|
||||
rtype = str(r.get("rel_type", "CONNECTS_TO")).upper()
|
||||
|
||||
src_upper = src.upper()
|
||||
tgt_upper = tgt.upper()
|
||||
|
||||
is_src_sink = any(s in src_upper for s in SINKS)
|
||||
is_tgt_sink = any(s in tgt_upper for s in SINKS)
|
||||
|
||||
if is_src_sink and not is_tgt_sink:
|
||||
# Invert inverted sink edge
|
||||
new_rel_type = "RELIEVES_TO" if ("FLARE" in src_upper or "VENT" in src_upper) else "DRAINS_TO"
|
||||
r_corr = {
|
||||
"source_tag": tgt,
|
||||
"target_tag": src,
|
||||
"rel_type": new_rel_type
|
||||
}
|
||||
else:
|
||||
r_corr = r
|
||||
|
||||
key = (r_corr["source_tag"], r_corr["target_tag"], r_corr["rel_type"])
|
||||
if key not in seen:
|
||||
seen.add(key)
|
||||
corrected.append(r_corr)
|
||||
|
||||
return corrected
|
||||
|
||||
|
||||
def _dist_to_segment(px: float, py: float, x1: float, y1: float, x2: float, y2: float) -> float:
|
||||
"""Calculates perpendicular distance from point (px, py) to line segment (x1, y1)-(x2, y2)."""
|
||||
dx = x2 - x1
|
||||
|
||||
@@ -610,6 +610,36 @@ def classify_paddle_results(
|
||||
flag_reason=flag_reason)
|
||||
item_added = True
|
||||
|
||||
# Check for operational reference context (e.g. FROM ..., TO ..., TIE-IN TO ...)
|
||||
is_ref_context = bool(re.search(r'\b(?:FROM|TO|TIE-IN|CONTINUED\s+ON|SEE\s+DWG|REF\s+DWG)\b', t, re.IGNORECASE))
|
||||
|
||||
# Split-suffix sibling instrument tags (e.g., 27-PY-0001BA/BB -> 27-PY-0001BA, 27-PY-0001BB)
|
||||
for m in re.finditer(r'\b(\d{2}-[A-Z]{2,4}-\d{3,5})([A-Z]{1,2})/([A-Z]{1,2})\b', t, re.IGNORECASE):
|
||||
base_prefix = m.group(1).upper()
|
||||
suf1 = m.group(2).upper()
|
||||
suf2 = m.group(3).upper()
|
||||
tag1 = f"{base_prefix}{suf1}"
|
||||
tag2 = f"{base_prefix}{suf2}"
|
||||
for tag in (tag1, tag2):
|
||||
if tag not in found:
|
||||
it_copy = dict(item)
|
||||
if is_ref_context:
|
||||
it_copy["is_reference"] = True
|
||||
found[tag] = _make_item(tag, 'INSTRUMENT_TAG', conf, it_copy)
|
||||
item_added = True
|
||||
|
||||
# Inverted Suction Strainers (e.g., 9002 S 26 -> 26-ST-9002)
|
||||
for m in re.finditer(r'\b(\d{4})\s*[-/]?\s*S\s*[-/]?\s*(\d{2})\b', t, re.IGNORECASE):
|
||||
seq = m.group(1)
|
||||
unit = m.group(2)
|
||||
st_tag = f"{unit}-ST-{seq}"
|
||||
if st_tag not in found:
|
||||
it_copy = dict(item)
|
||||
if is_ref_context:
|
||||
it_copy["is_reference"] = True
|
||||
found[st_tag] = _make_item(st_tag, 'EQUIPMENT_TAG', conf, it_copy)
|
||||
item_added = True
|
||||
|
||||
# Project-prefix tags (instruments + equipment)
|
||||
for m in _PROJECT_TAG_SEARCH.finditer(t):
|
||||
full_tag = m.group(1).upper()
|
||||
@@ -639,7 +669,10 @@ def classify_paddle_results(
|
||||
cat = 'EQUIPMENT_TAG'
|
||||
|
||||
if full_tag not in found:
|
||||
found[full_tag] = _make_item(full_tag, cat, conf, item)
|
||||
it_copy = dict(item)
|
||||
if is_ref_context:
|
||||
it_copy["is_reference"] = True
|
||||
found[full_tag] = _make_item(full_tag, cat, conf, it_copy)
|
||||
item_added = True
|
||||
|
||||
# Bare instrument tags — Defect 3: setpoint negative-context guard for 3-digit setpoints
|
||||
|
||||
@@ -69,6 +69,10 @@ def rectify_ocr_typos(text: str) -> str:
|
||||
cleaned = re.sub(r'\b(AS\d{2})5\b', r'\g<1>S', cleaned)
|
||||
cleaned = re.sub(r'\b(AC\d{2})5\b', r'\g<1>S', cleaned)
|
||||
|
||||
# 5. Fix dropped decimal points in low pressure ratings: 005BARG -> 0.005 BARG, 005 BARG -> 0.005 BARG
|
||||
cleaned = re.sub(r'(?<![\.\d])00(\d+)\s*(BARG|PSIG|BAR)\b', r'0.00\1 \2', cleaned, flags=re.IGNORECASE)
|
||||
cleaned = re.sub(r'(?<![\.\d])0([1-9]\d)\s*(BARG|PSIG|BAR)\b', r'0.\1 \2', cleaned, flags=re.IGNORECASE)
|
||||
|
||||
return cleaned
|
||||
|
||||
|
||||
|
||||
Reference in New Issue