feat: implement 3-agent audit recommendations: anti-hallucination line filter, sink flow directionality, split sibling instruments, suction strainer detection, and decimal point restoration
This commit is contained in:
+32
-5
@@ -262,8 +262,21 @@ class CompilerAgent(BaseAgent):
|
|||||||
compiled = []
|
compiled = []
|
||||||
line_tags = [t for t in texts if t["classification"] == "LINE_TAG"]
|
line_tags = [t for t in texts if t["classification"] == "LINE_TAG"]
|
||||||
|
|
||||||
|
# Anti-hallucination & Schema Validation Tokens
|
||||||
|
INVALID_LINE_TOKENS = {
|
||||||
|
'NOTE', 'TIT', 'PIT', 'LIT', 'FIT', 'PDI', 'PDT', 'PT', 'TT', 'FT', 'LT',
|
||||||
|
'REV', 'DWG', 'SHT', 'DETAIL', 'TYP', 'EL', 'M01', 'M02', 'M03', 'MOTOR'
|
||||||
|
}
|
||||||
|
|
||||||
for lt in line_tags:
|
for lt in line_tags:
|
||||||
tag = lt["tag"]
|
tag = lt["tag"]
|
||||||
|
|
||||||
|
# ── Pre-Export Schema Validator & Anti-Hallucination Filter ────────
|
||||||
|
# 1. Reject motor tags or electrical cable circuits (e.g., 26-KA-902-M01, TT-26-9711-AS20-00)
|
||||||
|
tag_upper = tag.upper()
|
||||||
|
if re.search(r'-(?:M\d{2}|C0\d)$', tag_upper) or tag_upper.startswith(('TT-', 'PT-', 'LT-', 'FT-', 'TIT-', 'PIT-', 'LIT-', 'FIT-')):
|
||||||
|
continue
|
||||||
|
|
||||||
# Intelligently split tag and detect whether size prefix is present
|
# Intelligently split tag and detect whether size prefix is present
|
||||||
parts = [p.strip() for p in tag.split('-') if p.strip()]
|
parts = [p.strip() for p in tag.split('-') if p.strip()]
|
||||||
|
|
||||||
@@ -306,6 +319,14 @@ class CompilerAgent(BaseAgent):
|
|||||||
spec = rem[3]
|
spec = rem[3]
|
||||||
insulation = rem[4]
|
insulation = rem[4]
|
||||||
|
|
||||||
|
# 2. Reject if service or spec was force-fitted with descriptive/note tokens (e.g. ...-NOTE, ...-TIT)
|
||||||
|
if service.upper() in INVALID_LINE_TOKENS or spec.upper() in INVALID_LINE_TOKENS:
|
||||||
|
continue
|
||||||
|
|
||||||
|
# 3. Reject if service code is not a clean alphabetic fluid/system descriptor
|
||||||
|
if not re.match(r'^[A-Z]{1,4}$', service.upper()):
|
||||||
|
continue
|
||||||
|
|
||||||
path_coords = None
|
path_coords = None
|
||||||
for trace in geom.get("traces", []):
|
for trace in geom.get("traces", []):
|
||||||
if trace["tag"] == tag:
|
if trace["tag"] == tag:
|
||||||
@@ -783,16 +804,22 @@ class CompilerAgent(BaseAgent):
|
|||||||
or "N/A"
|
or "N/A"
|
||||||
)
|
)
|
||||||
|
|
||||||
# Auto-detect relief destination from notes/service callout (e.g. FLARE / CLOSED DRAIN)
|
# Auto-detect relief destination from notes/service callout (e.g. HP FLARE vs LP FLARE)
|
||||||
destination = attrs.get("relief_destination")
|
destination = attrs.get("relief_destination")
|
||||||
if not destination:
|
if not destination:
|
||||||
for t in texts:
|
for t in texts:
|
||||||
val = t.get("value", "")
|
val = t.get("value", "").upper()
|
||||||
if "FLARE" in val.upper() or "DRAIN" in val.upper():
|
if "HP FLARE" in val or "HP-FLARE" in val or "HIGH PRESSURE FLARE" in val:
|
||||||
destination = val.strip()
|
destination = "HP Flare Header"
|
||||||
|
break
|
||||||
|
elif "LP FLARE" in val or "LP-FLARE" in val or "LOW PRESSURE FLARE" in val:
|
||||||
|
destination = "LP Flare Header"
|
||||||
|
break
|
||||||
|
elif "CLOSED DRAIN" in val or "DRAIN" in val:
|
||||||
|
destination = "Closed Drain Header"
|
||||||
break
|
break
|
||||||
if not destination:
|
if not destination:
|
||||||
destination = "LP Flare Header"
|
destination = "HP Flare Header"
|
||||||
|
|
||||||
compiled.append(SafetyReliefValveItem(
|
compiled.append(SafetyReliefValveItem(
|
||||||
tag=tag,
|
tag=tag,
|
||||||
|
|||||||
@@ -333,6 +333,9 @@ def trace_lines_and_connections(
|
|||||||
"rel_type": "EARTHED_TO"
|
"rel_type": "EARTHED_TO"
|
||||||
})
|
})
|
||||||
|
|
||||||
|
# ── Engineering Flow Directionality & Sink Constraint Enforcement ─────────
|
||||||
|
relations = _enforce_engineering_directionality(relations)
|
||||||
|
|
||||||
logger.info(
|
logger.info(
|
||||||
f"line_tracer: Extracted {len(traces)} line traces & {len(relations)} topological relations."
|
f"line_tracer: Extracted {len(traces)} line traces & {len(relations)} topological relations."
|
||||||
)
|
)
|
||||||
@@ -346,6 +349,51 @@ def trace_lines_and_connections(
|
|||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
|
def _enforce_engineering_directionality(relations: List[Dict[str, Any]]) -> List[Dict[str, Any]]:
|
||||||
|
"""
|
||||||
|
Enforces process engineering topological constraints:
|
||||||
|
1. Nodes designated as FLARE, ATMOSPHERE, DRAIN, SUMP, SEWER, VENT are terminal SINKS.
|
||||||
|
They cannot have outgoing 'feeds' or 'connects_to' edges to process equipment/valves.
|
||||||
|
2. Inverts inverted edges (e.g., 'LP FLARE feeds 26-CK-921' -> '26-CK-921 relieves_to LP FLARE').
|
||||||
|
"""
|
||||||
|
SINKS = (
|
||||||
|
'FLARE', 'HP FLARE', 'LP FLARE', 'HP_FLARE', 'LP_FLARE',
|
||||||
|
'DRAIN', 'CLOSED DRAIN', 'OPEN DRAIN', 'CLOSED_DRAIN', 'OPEN_DRAIN',
|
||||||
|
'ATMOSPHERE', 'SUMP', 'SEWER', 'VENT', 'SCRAP'
|
||||||
|
)
|
||||||
|
corrected = []
|
||||||
|
seen = set()
|
||||||
|
|
||||||
|
for r in relations:
|
||||||
|
src = str(r.get("source_tag", "")).strip()
|
||||||
|
tgt = str(r.get("target_tag", "")).strip()
|
||||||
|
rtype = str(r.get("rel_type", "CONNECTS_TO")).upper()
|
||||||
|
|
||||||
|
src_upper = src.upper()
|
||||||
|
tgt_upper = tgt.upper()
|
||||||
|
|
||||||
|
is_src_sink = any(s in src_upper for s in SINKS)
|
||||||
|
is_tgt_sink = any(s in tgt_upper for s in SINKS)
|
||||||
|
|
||||||
|
if is_src_sink and not is_tgt_sink:
|
||||||
|
# Invert inverted sink edge
|
||||||
|
new_rel_type = "RELIEVES_TO" if ("FLARE" in src_upper or "VENT" in src_upper) else "DRAINS_TO"
|
||||||
|
r_corr = {
|
||||||
|
"source_tag": tgt,
|
||||||
|
"target_tag": src,
|
||||||
|
"rel_type": new_rel_type
|
||||||
|
}
|
||||||
|
else:
|
||||||
|
r_corr = r
|
||||||
|
|
||||||
|
key = (r_corr["source_tag"], r_corr["target_tag"], r_corr["rel_type"])
|
||||||
|
if key not in seen:
|
||||||
|
seen.add(key)
|
||||||
|
corrected.append(r_corr)
|
||||||
|
|
||||||
|
return corrected
|
||||||
|
|
||||||
|
|
||||||
def _dist_to_segment(px: float, py: float, x1: float, y1: float, x2: float, y2: float) -> float:
|
def _dist_to_segment(px: float, py: float, x1: float, y1: float, x2: float, y2: float) -> float:
|
||||||
"""Calculates perpendicular distance from point (px, py) to line segment (x1, y1)-(x2, y2)."""
|
"""Calculates perpendicular distance from point (px, py) to line segment (x1, y1)-(x2, y2)."""
|
||||||
dx = x2 - x1
|
dx = x2 - x1
|
||||||
|
|||||||
@@ -610,6 +610,36 @@ def classify_paddle_results(
|
|||||||
flag_reason=flag_reason)
|
flag_reason=flag_reason)
|
||||||
item_added = True
|
item_added = True
|
||||||
|
|
||||||
|
# Check for operational reference context (e.g. FROM ..., TO ..., TIE-IN TO ...)
|
||||||
|
is_ref_context = bool(re.search(r'\b(?:FROM|TO|TIE-IN|CONTINUED\s+ON|SEE\s+DWG|REF\s+DWG)\b', t, re.IGNORECASE))
|
||||||
|
|
||||||
|
# Split-suffix sibling instrument tags (e.g., 27-PY-0001BA/BB -> 27-PY-0001BA, 27-PY-0001BB)
|
||||||
|
for m in re.finditer(r'\b(\d{2}-[A-Z]{2,4}-\d{3,5})([A-Z]{1,2})/([A-Z]{1,2})\b', t, re.IGNORECASE):
|
||||||
|
base_prefix = m.group(1).upper()
|
||||||
|
suf1 = m.group(2).upper()
|
||||||
|
suf2 = m.group(3).upper()
|
||||||
|
tag1 = f"{base_prefix}{suf1}"
|
||||||
|
tag2 = f"{base_prefix}{suf2}"
|
||||||
|
for tag in (tag1, tag2):
|
||||||
|
if tag not in found:
|
||||||
|
it_copy = dict(item)
|
||||||
|
if is_ref_context:
|
||||||
|
it_copy["is_reference"] = True
|
||||||
|
found[tag] = _make_item(tag, 'INSTRUMENT_TAG', conf, it_copy)
|
||||||
|
item_added = True
|
||||||
|
|
||||||
|
# Inverted Suction Strainers (e.g., 9002 S 26 -> 26-ST-9002)
|
||||||
|
for m in re.finditer(r'\b(\d{4})\s*[-/]?\s*S\s*[-/]?\s*(\d{2})\b', t, re.IGNORECASE):
|
||||||
|
seq = m.group(1)
|
||||||
|
unit = m.group(2)
|
||||||
|
st_tag = f"{unit}-ST-{seq}"
|
||||||
|
if st_tag not in found:
|
||||||
|
it_copy = dict(item)
|
||||||
|
if is_ref_context:
|
||||||
|
it_copy["is_reference"] = True
|
||||||
|
found[st_tag] = _make_item(st_tag, 'EQUIPMENT_TAG', conf, it_copy)
|
||||||
|
item_added = True
|
||||||
|
|
||||||
# Project-prefix tags (instruments + equipment)
|
# Project-prefix tags (instruments + equipment)
|
||||||
for m in _PROJECT_TAG_SEARCH.finditer(t):
|
for m in _PROJECT_TAG_SEARCH.finditer(t):
|
||||||
full_tag = m.group(1).upper()
|
full_tag = m.group(1).upper()
|
||||||
@@ -639,7 +669,10 @@ def classify_paddle_results(
|
|||||||
cat = 'EQUIPMENT_TAG'
|
cat = 'EQUIPMENT_TAG'
|
||||||
|
|
||||||
if full_tag not in found:
|
if full_tag not in found:
|
||||||
found[full_tag] = _make_item(full_tag, cat, conf, item)
|
it_copy = dict(item)
|
||||||
|
if is_ref_context:
|
||||||
|
it_copy["is_reference"] = True
|
||||||
|
found[full_tag] = _make_item(full_tag, cat, conf, it_copy)
|
||||||
item_added = True
|
item_added = True
|
||||||
|
|
||||||
# Bare instrument tags — Defect 3: setpoint negative-context guard for 3-digit setpoints
|
# Bare instrument tags — Defect 3: setpoint negative-context guard for 3-digit setpoints
|
||||||
|
|||||||
@@ -69,6 +69,10 @@ def rectify_ocr_typos(text: str) -> str:
|
|||||||
cleaned = re.sub(r'\b(AS\d{2})5\b', r'\g<1>S', cleaned)
|
cleaned = re.sub(r'\b(AS\d{2})5\b', r'\g<1>S', cleaned)
|
||||||
cleaned = re.sub(r'\b(AC\d{2})5\b', r'\g<1>S', cleaned)
|
cleaned = re.sub(r'\b(AC\d{2})5\b', r'\g<1>S', cleaned)
|
||||||
|
|
||||||
|
# 5. Fix dropped decimal points in low pressure ratings: 005BARG -> 0.005 BARG, 005 BARG -> 0.005 BARG
|
||||||
|
cleaned = re.sub(r'(?<![\.\d])00(\d+)\s*(BARG|PSIG|BAR)\b', r'0.00\1 \2', cleaned, flags=re.IGNORECASE)
|
||||||
|
cleaned = re.sub(r'(?<![\.\d])0([1-9]\d)\s*(BARG|PSIG|BAR)\b', r'0.\1 \2', cleaned, flags=re.IGNORECASE)
|
||||||
|
|
||||||
return cleaned
|
return cleaned
|
||||||
|
|
||||||
|
|
||||||
|
|||||||
@@ -178,7 +178,52 @@ def run_tests():
|
|||||||
]
|
]
|
||||||
compiled_psv = ca._compile_safety_relief_valves(psv_texts, [])
|
compiled_psv = ca._compile_safety_relief_valves(psv_texts, [])
|
||||||
assert_test(len(compiled_psv) == 1 and compiled_psv[0].unit == "26", "PSV-9066A recovered Unit 26 (not NaN)")
|
assert_test(len(compiled_psv) == 1 and compiled_psv[0].unit == "26", "PSV-9066A recovered Unit 26 (not NaN)")
|
||||||
assert_test(compiled_psv[0].relief_destination == "LP Flare Header", "PSV-9066A assigned LP Flare Header destination")
|
assert_test(compiled_psv[0].relief_destination == "HP Flare Header", "PSV-9066A assigned HP Flare Header destination")
|
||||||
|
|
||||||
|
print("\n" + "=" * 70)
|
||||||
|
print("6. TESTING ADVANCED RECOMMENDATIONS (AGENT AUDIT VERIFICATION)")
|
||||||
|
print("=" * 70)
|
||||||
|
# A. Anti-hallucination line filter
|
||||||
|
hallucinated_line_texts = [
|
||||||
|
{"classification": "LINE_TAG", "tag": '1 1/2"-FE-9017-NOTE', "value": '1 1/2"-FE-9017-NOTE'},
|
||||||
|
{"classification": "LINE_TAG", "tag": '1/2"-TIT-9018-TIT', "value": '1/2"-TIT-9018-TIT'},
|
||||||
|
{"classification": "LINE_TAG", "tag": '26-KA-902-M01', "value": '26-KA-902-M01'},
|
||||||
|
{"classification": "LINE_TAG", "tag": 'TT-26-9711-AS20-00', "value": 'TT-26-9711-AS20-00'},
|
||||||
|
{"classification": "LINE_TAG", "tag": '10"-VF-43-9027-AS20S-00', "value": '10"-VF-43-9027-AS20S-00'},
|
||||||
|
]
|
||||||
|
compiled_clean_lines = ca._compile_lines(hallucinated_line_texts, {}, [])
|
||||||
|
clean_line_tags = [l.tag for l in compiled_clean_lines]
|
||||||
|
assert_test('1 1/2"-FE-9017-NOTE' not in clean_line_tags, "Rejected hallucinated line '...-NOTE'")
|
||||||
|
assert_test('1/2"-TIT-9018-TIT' not in clean_line_tags, "Rejected hallucinated line '...-TIT'")
|
||||||
|
assert_test('26-KA-902-M01' not in clean_line_tags, "Rejected motor tag '26-KA-902-M01' from Line List")
|
||||||
|
assert_test('TT-26-9711-AS20-00' not in clean_line_tags, "Rejected transmitter cable tag 'TT-26-...' from Line List")
|
||||||
|
assert_test('10"-VF-43-9027-AS20S-00' in clean_line_tags, "Retained legitimate process piping line")
|
||||||
|
|
||||||
|
# B. Directionality & Sink Constraint Enforcement
|
||||||
|
from src.utils.line_tracer import _enforce_engineering_directionality
|
||||||
|
raw_relations = [
|
||||||
|
{"source_tag": "LP FLARE", "target_tag": "26-CK-921", "rel_type": "FEEDS"},
|
||||||
|
{"source_tag": "CLOSED DRAIN", "target_tag": "26-HA-911", "rel_type": "FEEDS"},
|
||||||
|
{"source_tag": "26-KA-901", "target_tag": '10"-VF-43-9027-AS20S-00', "rel_type": "FEEDS"},
|
||||||
|
]
|
||||||
|
corrected_rels = _enforce_engineering_directionality(raw_relations)
|
||||||
|
corr_map = {(r["source_tag"], r["target_tag"]): r["rel_type"] for r in corrected_rels}
|
||||||
|
assert_test(("26-CK-921", "LP FLARE") in corr_map and corr_map[("26-CK-921", "LP FLARE")] == "RELIEVES_TO", "Inverted 'LP FLARE feeds 26-CK-921' to '26-CK-921 relieves_to LP FLARE'")
|
||||||
|
assert_test(("26-HA-911", "CLOSED DRAIN") in corr_map and corr_map[("26-HA-911", "CLOSED DRAIN")] == "DRAINS_TO", "Inverted 'CLOSED DRAIN feeds 26-HA-911' to '26-HA-911 drains_to CLOSED DRAIN'")
|
||||||
|
assert_test(("26-KA-901", '10"-VF-43-9027-AS20S-00') in corr_map, "Preserved valid compressor feed line relation")
|
||||||
|
|
||||||
|
# C. Split sibling tags & inverted suction strainer detection
|
||||||
|
audit_ocr_items = [
|
||||||
|
{"text": "27-PY-0001BA/BB", "confidence": 0.95, "attributes": {}},
|
||||||
|
{"text": "9002 S 26", "confidence": 0.95, "attributes": {}},
|
||||||
|
{"text": "005BARG", "confidence": 0.95, "attributes": {}},
|
||||||
|
]
|
||||||
|
audit_classified = classify_paddle_results(audit_ocr_items, "PID")
|
||||||
|
audit_tags = {c["tag"]: c for c in audit_classified}
|
||||||
|
assert_test("27-PY-0001BA" in audit_tags and audit_tags["27-PY-0001BA"]["classification"] == "INSTRUMENT_TAG", "Extracted sibling instrument 27-PY-0001BA")
|
||||||
|
assert_test("27-PY-0001BB" in audit_tags and audit_tags["27-PY-0001BB"]["classification"] == "INSTRUMENT_TAG", "Extracted sibling instrument 27-PY-0001BB")
|
||||||
|
assert_test("26-ST-9002" in audit_tags and audit_tags["26-ST-9002"]["classification"] == "EQUIPMENT_TAG", "Recognized suction strainer '9002 S 26' as 26-ST-9002")
|
||||||
|
assert_test(rectify_ocr_typos("005BARG") == "0.005 BARG", "Restored dropped decimal point '005BARG' -> '0.005 BARG'")
|
||||||
|
|
||||||
print("\n" + "=" * 70)
|
print("\n" + "=" * 70)
|
||||||
print(f"FINAL RESULT: {total_passed}/{total_tests} Tests Passed (100% Precision Verified Across All Categories)")
|
print(f"FINAL RESULT: {total_passed}/{total_tests} Tests Passed (100% Precision Verified Across All Categories)")
|
||||||
|
|||||||
Reference in New Issue