fix(pipeline): complete Round 4 repair pass - restore instrument recall, fix spatial line callouts, enable equipment datasheets & twin PSVs
This commit is contained in:
@@ -79,3 +79,32 @@ class TestLineTagGrammar:
|
||||
"Expected a flag_reason for out-of-range size 900"
|
||||
)
|
||||
|
||||
def test_line_from_to_spatial_isolation(self):
|
||||
"""
|
||||
Priority 2 Fix: Assert that an off-page annotation text (FROM 27-PIT-0001B)
|
||||
is ONLY assigned to the line spatially adjacent to it, and unrelated lines
|
||||
elsewhere on the sheet do NOT inherit that annotation string.
|
||||
"""
|
||||
from src.agents.compiler import CompilerAgent
|
||||
from src.models import UniversalEngineeringGraph
|
||||
|
||||
compiler = CompilerAgent()
|
||||
texts = [
|
||||
{"value": "FROM 27-PIT-0001B IN 3RD STAGE", "classification": "NOTE", "attributes": {"pos_x": 0.10, "pos_y": 0.10}},
|
||||
{"value": "8\"-PV-26-9035-FC11S-08", "classification": "LINE_TAG", "tag": "8\"-PV-26-9035-FC11S-08", "attributes": {"pos_x": 0.11, "pos_y": 0.11}},
|
||||
{"value": "3\"-VA-26-9121-AC21-00", "classification": "LINE_TAG", "tag": "3\"-VA-26-9121-AC21-00", "attributes": {"pos_x": 0.85, "pos_y": 0.85}},
|
||||
]
|
||||
geom = {"traces": [
|
||||
{"tag": "8\"-PV-26-9035-FC11S-08", "grid_path": [[0.11, 0.11]]},
|
||||
{"tag": "3\"-VA-26-9121-AC21-00", "grid_path": [[0.85, 0.85]]},
|
||||
]}
|
||||
lines = compiler._compile_lines(texts, geom, [])
|
||||
|
||||
line1 = next(l for l in lines if "9035" in l.tag)
|
||||
line2 = next(l for l in lines if "9121" in l.tag)
|
||||
|
||||
# Line 1 (close at 0.11, 0.11) SHOULD get the off-page callout
|
||||
assert line1.from_node is not None and "27-PIT-0001B" in line1.from_node
|
||||
# Line 2 (far away at 0.85, 0.85) MUST NOT inherit that callout
|
||||
assert line2.from_node is None
|
||||
|
||||
|
||||
@@ -179,3 +179,42 @@ class TestEquipmentDatasheet:
|
||||
assert flange["outlet_size"] == '4"'
|
||||
assert flange["inlet_spec"] == "300#"
|
||||
|
||||
def test_twin_psv_flange_spec_inheritance(self):
|
||||
"""
|
||||
Priority 4 Fix: Twin PSVs 26-PSV-9027A and 26-PSV-9027B must both inherit
|
||||
flange specs extracted from the shared cluster.
|
||||
"""
|
||||
from src.agents.parallel_vision import _inject_datasheet_attributes
|
||||
structured = [
|
||||
{"tag": "26-PSV-9027A", "classification": "PSV_TAG", "attributes": {"pos_y": 0.50, "pos_x": 0.50}},
|
||||
{"tag": "26-PSV-9027B", "classification": "PSV_TAG", "attributes": {"pos_y": 0.52, "pos_x": 0.50}},
|
||||
]
|
||||
ocr_items = [
|
||||
{"text": '3"x4" 300# 150#', "center_y": 0.51, "center_x": 0.50},
|
||||
]
|
||||
enriched = _inject_datasheet_attributes(structured, ocr_items)
|
||||
psv_a = next(i for i in enriched if i["tag"] == "26-PSV-9027A")
|
||||
psv_b = next(i for i in enriched if i["tag"] == "26-PSV-9027B")
|
||||
|
||||
assert psv_a["attributes"].get("inlet_size") == '3"'
|
||||
assert psv_b["attributes"].get("inlet_size") == '3"'
|
||||
|
||||
def test_equipment_completeness_confidence_scaling(self):
|
||||
"""
|
||||
Criteria 5 Fix: Equipment with full 7/7 datasheet fields must have 1.0 (100%) confidence,
|
||||
while equipment with 0 datasheet fields must have 0.60 (60%) confidence.
|
||||
"""
|
||||
from src.agents.compiler import CompilerAgent
|
||||
compiler = CompilerAgent()
|
||||
|
||||
full_eq = [{"classification": "EQUIPMENT_TAG", "tag": "26-KA-902", "value": "Compressor",
|
||||
"attributes": {"duty": "1835 kW", "flow_rate": "62809 kg/h", "design_pressure": "286 Barg",
|
||||
"design_temperature": "160 C", "material": "LTCS", "vendor": "MAN", "quantity": "1"}}]
|
||||
empty_eq = [{"classification": "EQUIPMENT_TAG", "tag": "26-KA-903", "value": "Compressor", "attributes": {}}]
|
||||
|
||||
res_full = compiler._compile_equipment(full_eq, [])
|
||||
res_empty = compiler._compile_equipment(empty_eq, [])
|
||||
|
||||
assert res_full[0].confidence == 1.0
|
||||
assert res_empty[0].confidence == 0.60
|
||||
|
||||
|
||||
@@ -126,3 +126,19 @@ class TestSetpointFilter:
|
||||
]
|
||||
assert _is_setpoint_context_spatial(0, items) is True
|
||||
|
||||
def test_real_instrument_next_to_setpoint_text_kept(self):
|
||||
"""
|
||||
Priority 1 Fix: Real instrument TIT-9025 adjacent to 'SD HH: 150 BARG'
|
||||
must be KEPT as INSTRUMENT_TAG, while bare setpoint PI-150 must be REJECTED.
|
||||
"""
|
||||
items = [
|
||||
{"text": "26-TIT-9025", "confidence": 0.95, "center_x": 0.50, "center_y": 0.30},
|
||||
{"text": "TIT-9025", "confidence": 0.95, "center_x": 0.50, "center_y": 0.31},
|
||||
{"text": "SD HH: 150 BARG", "confidence": 0.95, "center_x": 0.52, "center_y": 0.32},
|
||||
{"text": "PI-150", "confidence": 0.95, "center_x": 0.52, "center_y": 0.33},
|
||||
]
|
||||
result = classify_paddle_results(items, drawing_type="PID")
|
||||
inst_tags = [r["tag"] for r in result if r["classification"] == "INSTRUMENT_TAG"]
|
||||
assert "26-TIT-9025" in inst_tags or "TIT-9025" in inst_tags
|
||||
assert "PI-150" not in inst_tags
|
||||
|
||||
|
||||