From f92e23accd93a39cf5e4f9a0823ac958b82e17d9 Mon Sep 17 00:00:00 2001 From: Abhinav Gupta Date: Thu, 3 Sep 2026 11:41:37 +0530 Subject: [PATCH] feat: enhance all multi-agent vision, reasoning, symbol, topology, and ingestion prompts with industrial engineering specifications --- src/agents/ingestion.py | 35 +++---- src/agents/parallel_vision.py | 167 +++++++++++++++++++--------------- src/agents/re_extractor.py | 16 +++- src/agents/supervisor.py | 14 ++- 4 files changed, 136 insertions(+), 96 deletions(-) diff --git a/src/agents/ingestion.py b/src/agents/ingestion.py index e0220d0..fcd321f 100644 --- a/src/agents/ingestion.py +++ b/src/agents/ingestion.py @@ -258,25 +258,28 @@ class IngestionAgent(BaseAgent): Drawing-type detection is built into the schema and prompt — works for any discipline. """ system_instruction = ( - "You are a professional engineering document ingestion system. " - "Examine the provided engineering drawing image, look closely at the title block, " - "sheet headers, and drawing notes. Extract structured metadata accurately. " - "Identify the drawing type from the drawing content and title — it may be a P&ID, " - "Electrical Layout, Earthing Layout, SLD, HVAC, Structural, or other discipline." + "You are a senior engineering document control specialist. " + "Examine the engineering drawing canvas, focusing on the title block (bottom-right), " + "drawing header frames, revision history tables, and drawing notes blocks. " + "Extract complete, standardized metadata across all engineering disciplines." ) prompt = ( - "Extract the following metadata from this engineering drawing. " - "Look carefully at the title block (usually bottom-right) and all sheet headers:\n\n" - "- drawing_type: One of: PID, PFD, ELECTRICAL_LAYOUT, EARTHING_LAYOUT, SLD, " - "HVAC_LAYOUT, STRUCTURAL_LAYOUT, ISOMETRIC, CABLE_SCHEDULE, GENERIC\n" - "- discipline: Engineering discipline (Process, Electrical, Mechanical, Civil, etc.)\n" - "- drawing_number: Unique document/sheet number from title block\n" - "- title: Full title as written on the drawing (e.g., LIGHTING LAYOUT - 1, EARTHING LAYOUT)\n" - "- revision: Revision character or number (e.g., 0, 1, A, B)\n" - "- client_name: Owner or client name if shown\n" - "- page_count: Total sheets if multi-sheet package, otherwise 1\n\n" - f"Filename hint (may help identify drawing type): {filename or 'N/A'}" + "Dissect the engineering drawing title block and border frames to extract complete document metadata:\n\n" + "1. drawing_type: Standardized discipline category:\n" + " - PID: Piping and Instrumentation Diagram\n" + " - PFD: Process Flow Diagram\n" + " - ELECTRICAL_LAYOUT: Lighting, power, cable routing layout\n" + " - EARTHING_LAYOUT: Grounding and lightning protection layout\n" + " - SLD: Single Line Diagram / Electrical schematic\n" + " - HVAC_LAYOUT / STRUCTURAL_LAYOUT / ISOMETRIC / CABLE_SCHEDULE / GENERIC\n\n" + "2. drawing_number: Exact official drawing / document number (e.g., 26-00-14-101, DWG-EL-0042-01).\n" + "3. title: Full primary title and subtitle as formatted in the title block (e.g., 'LIFT GAS COMPRESSOR SYSTEM', 'LIGHTING LAYOUT - LEVEL 1').\n" + "4. discipline: Primary engineering discipline (Process, Piping, Electrical, Instrumentation, Mechanical, Civil/Structural).\n" + "5. revision: Latest revision code from the revision block (e.g., '0', '1', 'A', 'B', 'REV 02').\n" + "6. client_name: Facility owner, operator, or EPC contractor name from title block logo area.\n" + "7. page_count: Total sheet count if part of a multi-sheet drawing set (otherwise 1).\n\n" + f"Filename Hint: {filename or 'N/A'}" ) try: diff --git a/src/agents/parallel_vision.py b/src/agents/parallel_vision.py index 6688558..df83524 100644 --- a/src/agents/parallel_vision.py +++ b/src/agents/parallel_vision.py @@ -84,60 +84,56 @@ def _deduplicate_tiled_boxes(raw_boxes: List[Dict[str, Any]], iou_thresh: float # ────────────────────────────────────────────────────────────────────────────── _PID_TAG_CATEGORIES = ( - " - EQUIPMENT_TAG: Compressors, motors, vessels, skids, coolers, filters " - "(e.g., 26-KA-901, TK-101, P-101).\n" - " - LINE_TAG: Piping run descriptions with size, fluid service, spec class " - "(e.g., 8\"-PV-26-9035-FC11S-08, 3\"-VA-26-9121-AC21-00).\n" - " - INSTRUMENT_TAG: Sensors, bubbles, transmitters, indicators " - "(e.g., PIT-9062, TIT-9057, PDIT-9054).\n" - " - VALVE_TAG: Manual, control, check, gate, globe, needle valves " - "(e.g., 26GB9178, HV-101, XV-201).\n" - " - PSV_TAG: Pressure Safety Valves (e.g., 26-PSV-9066A, PSV-101A).\n" - " - NOTE: Plain English notes, descriptions, labels (e.g., HIGH POINT, NOTE 35).\n" - " - RATING: Numeric specs like 150#, 2500#, pressure classes.\n" + " - EQUIPMENT_TAG: Process equipment tags with or without area prefix (e.g. 26-KA-902 compressor, " + "26-CX-9021 coalescing filter, 26-HA-911 heat exchanger, 26-TK-9001 storage tank, 26-ST-9002 suction strainer, " + "26-PA-901A pump). Capture sub-trains (e.g. HA-911-C01, HA-911-C02) and extract all dense datasheet block parameters " + "(duty, design pressure, design temperature, flow rate, material, vendor, motor rating) into attributes.\n" + " - LINE_TAG: Complete piping line designations following ISA format [Size]-[Service]-[Area]-[Sequence]-[Spec]-[Insulation] " + "(e.g. 8\"-PV-26-9035-FC11S-08, 10\"-VF-43-9027-AS20S-00, 3\"-VA-26-9121-AC21-00). Do NOT invent notes or note suffixes. " + "Reject electrical cables, transmitter loops, or motor tags from line list.\n" + " - INSTRUMENT_TAG: ISA 5.1 sensor bubbles, transmitters, switches, and relays (e.g. 26-PIT-9077, TIT-9057, " + "26-PDI-9054, 27-PY-0001BA/BB, ZIT-9011, VIT-9020). For split sibling tags ('BA/BB'), emit both individual items.\n" + " - VALVE_TAG: In-line manual and actuated valves with functional categorization (e.g. 26GB9178 Gate, 26CB9131 Check, " + "43BL9070 Ball, HV-101 Hand Control, XV-201 Shutdown, 26-ND-901 Needle, 26-BF-902 Butterfly). Extract ANSI rating class (150#, 300#, 2500#).\n" + " - PSV_TAG: Pressure Safety Relief Valves (e.g. 26-PSV-9066A, PSV-9027A, PSV-9027B). Capture set pressure (e.g. 225.4 bar(g)), " + "inlet/outlet sizes, and relief header destination (e.g. HP Flare Header, LP Flare Header).\n" + " - NOTE: Engineering callouts, revision notes, hold notes, and drawing reference markers (e.g. 'SEE DWG', 'HOLD', 'NOTE 12').\n" + " - RATING: Pressure/temperature ratings, flange classes (150#, 300#, 600#, 900#, 1500#, 2500#, PN16, PN40) and setpoint values.\n" ) _ELECTRICAL_TAG_CATEGORIES = ( - " - PANEL_TAG: Distribution boards, MDBs, LDBs, switchgear panels " - "(e.g., DB-01, MDB-A, LDB-3, EMDB, SMDB).\n" - " - LUMINAIRE_TAG: Light fittings, lamps, luminaires " - "(e.g., L-01, LS-201, TL-101, FL-01).\n" - " - CIRCUIT_TAG: Electrical circuits, breakers, MCBs " - "(e.g., C-101, CB-01, MCB-1, RCCB-3).\n" - " - ELEVATION_TAG: Elevation labels and level references " - "(e.g., EL.101.445, TL 100.000, EL +103.000).\n" - " - EQUIPMENT_TAG: Generic equipment tags (e.g., AHU-01, FAN-01, AC-01).\n" - " - NOTE: Wiring notes, area labels, installation notes.\n" - " - RATING: Electrical ratings (e.g., 415V, 32A, 3Φ).\n" + " - PANEL_TAG: Distribution boards, main switchboards, MDBs, LDBs, MCCs, control panels " + "(e.g. DB-01, MDB-A, LDB-3, EMDB, SMDB, MCC-26).\n" + " - LUMINAIRE_TAG: Light fittings, lamps, emergency exit lights, floodlights (e.g. L-01, LS-201, TL-101, FL-01, EX-01).\n" + " - CIRCUIT_TAG: Electrical branch circuits, circuit breakers, MCBs, MCCBs, fuses (e.g. C-101, CB-01, MCB-1, RCCB-3, DB-1/R1).\n" + " - ELEVATION_TAG: Elevation references and mounting heights (e.g. EL.101.445, TL 100.000, +2.400 AFF, +0.500 FFL).\n" + " - EQUIPMENT_TAG: Motors, HVAC units, transformers, generators, UPS, AHUs (e.g. M-101, TR-01, AHU-01, GEN-01).\n" + " - NOTE: Wiring specifications, installation notes, conduit sizes (e.g. 3x2.5mm² Cu/XLPE/PVC in 25mmØ conduit).\n" + " - RATING: Voltage, amperage, frequency ratings (e.g. 415V, 230V, 32A, 100A, 3Φ 50Hz, IP65, 2x36W).\n" ) _EARTHING_TAG_CATEGORIES = ( - " - EARTH_BAR_TAG: Earthing bars and main earth terminals " - "(e.g., EB-01, EBM-01, MEB).\n" - " - EARTH_PIT_TAG: Earth electrodes and earth pits " - "(e.g., EP-01, EP-A, earth pit).\n" - " - BOND_CONDUCTOR_TAG: Bonding conductors and earth cables " - "(e.g., BC-01, EC-01, earthing conductor).\n" - " - EQUIPMENT_TAG: Equipment being earthed (e.g., structural members, tanks, panels).\n" - " - ELEVATION_TAG: Elevation labels (e.g., EL.101.445, TL 100.000).\n" - " - NOTE: Installation notes, material specs (e.g., 50x6mm Copper Tape).\n" - " - RATING: Resistance values, conductor sizes (e.g., <1 Ohm, 95mm²).\n" + " - EARTH_BAR_TAG: Main earthing terminals, earth bars, clean earth bars (e.g. EB-01, EBM-01, MEB, EEB, TEB).\n" + " - EARTH_PIT_TAG: Earth test pits, earth electrodes, bore earth pits (e.g. EP-01, EP-A, TP-01, Earth Pit #4).\n" + " - BOND_CONDUCTOR_TAG: Earthing tape, bonding jumpers, grounding conductors (e.g. BC-01, EC-01, 50x6mm Cu Tape, 70mm² PVC Green/Yellow).\n" + " - EQUIPMENT_TAG: Structures, tanks, vessels, skids, motors, fence gates requiring grounding (e.g. TK-101, SK-01, Steel Column B4).\n" + " - ELEVATION_TAG: Ground elevation benchmarks and depth markings (e.g. EL.100.000, GL 0.000, -3.000m depth).\n" + " - NOTE: Resistance requirements and jointing specifications (e.g. '< 1.0 Ohm', 'Cadweld exothermic connection').\n" + " - RATING: Resistance and cross-sectional conductor ratings (e.g. 0.5 Ohm, 95mm², 120kA 1s).\n" ) _SLD_TAG_CATEGORIES = ( - " - PANEL_TAG: Switchgear, busbars, transformers, MVDBs, LVDBs " - "(e.g., MVDB-01, LVDB-A, TR-01, MSB).\n" - " - CIRCUIT_TAG: Feeders, breakers, contactors " - "(e.g., ACB-01, MCCB-3, VCB-01, feeder).\n" - " - EQUIPMENT_TAG: Motors, loads, generators (e.g., M-101, G-01).\n" - " - RATING: Electrical ratings (e.g., 11kV, 415V, 500kVA, 1250A).\n" - " - NOTE: Protection settings, fault levels, cable sizes.\n" + " - PANEL_TAG: Switchboards, busbars, MV/LV switchgear, motor control centers (e.g. MVDB-01, LVDB-A, TR-01, MSB, 11kV BUS-A).\n" + " - CIRCUIT_TAG: Air circuit breakers (ACB), vacuum circuit breakers (VCB), MCCBs, isolators, contactors (e.g. ACB-01, VCB-02, Q1, F1).\n" + " - EQUIPMENT_TAG: Heavy electrical loads, transformers, generators, variable frequency drives (VFD), motors (e.g. TR-01, M-101, VFD-01).\n" + " - RATING: Short circuit withstand, busbar current, voltage ratings (e.g. 11kV, 415V, 50kA 1s, 2500A, 500kVA, PF 0.85).\n" + " - NOTE: Protection relay settings, CT/PT ratios, interlock logic (e.g. 50/51 100/5A 5P20, Kast key interlock).\n" ) _GENERIC_TAG_CATEGORIES = ( - " - EQUIPMENT_TAG: Any equipment with a tag number (e.g., TK-101, P-101, E-201).\n" - " - NOTE: Labels, descriptions, specifications.\n" - " - RATING: Numeric specifications.\n" + " - EQUIPMENT_TAG: Any tagged industrial equipment or mechanical assembly (e.g. TK-101, P-101, E-201, C-101).\n" + " - NOTE: Descriptive engineering text, labels, instructions, material notes.\n" + " - RATING: Physical, electrical, or thermal ratings.\n" ) _SYMBOL_VOCAB: Dict[str, str] = { @@ -540,16 +536,29 @@ class TextRecognitionAgent(BaseAgent): tag_categories = _get_tag_categories(drawing_type) reasoning_prompt = ( - f"You are an expert engineering data parser and reasoning engine for {drawing_type.replace('_', ' ')} drawings.\n" - "Below is the Layer 1 OCR output extracted from the drawing:\n" + f"You are a senior process and electrical engineering data parser and reasoning engine analyzing a {drawing_type.replace('_', ' ')} drawing.\n" + "Below is the Layer 1 raw OCR text elements extracted from the drawing:\n" " | conf= | pos=(, )\n\n" f"RAW OCR TEXT FROM LAYER 1:\n{raw_text_block}\n\n" - "PERFORM DEEP REASONING & REFINEMENT:\n" - "1. FIX OCR TYPOS: Correct misread letters/digits (e.g., P1T-9055 -> PIT-9055, 0B-01 -> DB-01, E8-01 -> EB-01).\n" - "2. RECOMBINE SPLIT TEXT: Re-assemble tags that were split across multiple OCR lines.\n" - "3. IDENTIFY MISPLACED DATA: Map nearby specifications (design pressure, design temp, wattage, rating, cable size, elevation, material, duty) into the parent tag's attributes dict.\n" - "4. FIND MISSING TAGS/ENTITIES: Visually inspect the drawing image to find any missing tags or equipment referenced in callouts or note blocks.\n" - "5. CLASSIFY & STRUCTURE: Map every entity into ONE of the following categories:\n" + "EXECUTE RIGOROUS ENGINEERING REASONING & REFINEMENT:\n" + "1. FIX OCR TYPOS & DECIMAL POINTS:\n" + " - Correct misread characters (e.g., P1T-9055 -> PIT-9055, 0B-01 -> DB-01, E8-01 -> EB-01, FC115 -> FC11S, B\" -> 8\").\n" + " - Restore zero-prefixed missing decimal points in pressure ratings (e.g., '005BARG' -> '0.005 BARG', '050BARG' -> '0.50 BARG').\n" + "2. RECOMBINE SPATIALLY SPLIT TEXT:\n" + " - Re-assemble multi-line piping strings (e.g., size '8\"', service 'PV', spec 'FC11S' on adjacent lines -> '8\"-PV-26-9035-FC11S-08').\n" + " - Re-assemble split valve and instrument tags (e.g., 'HV-' and '101' -> 'HV-101').\n" + "3. SPLIT SIBLING TAGS & INVERTED NOTATIONS:\n" + " - Split dual instrument transmitter tags (e.g., '27-PY-0001BA/BB' -> emit '27-PY-0001BA' and '27-PY-0001BB').\n" + " - Invert drawing-specific suction strainer tags (e.g., '9002 S 26' -> emit '26-ST-9002' as EQUIPMENT_TAG).\n" + "4. EQUIPMENT DATASHEET & ATTRIBUTE BINDING:\n" + " - Parse dense parameter blocks (Duty, Design Pressure, Design Temp, Flow Rate, Material, Vendor, Flange Rating) and inject them into the parent equipment/valve attributes dict.\n" + " - For PSVs, capture exact set pressure (e.g., '225.4 bar(g)'), inlet/outlet sizes, and relief header destination ('HP Flare Header').\n" + "5. ANTI-HALLUCINATION & STRICT SCHEMA VALIDATION:\n" + " - Do NOT invent placeholder suffixes ('...-NOTE', '...-TIT') in piping lines.\n" + " - Do NOT classify motor tags (e.g., '26-KA-902-M01') or instrument wires as lines.\n" + " - Ensure reference callouts ('FROM DWG', 'CONTINUED ON') are marked as reference notes.\n" + "6. CLASSIFY & STRUCTURE:\n" + " - Categorize every entity accurately into ONE of the following classes:\n" + tag_categories + "\n" "Return the cleaned, structured findings as a validated RawTextList JSON." ) @@ -558,8 +567,8 @@ class TextRecognitionAgent(BaseAgent): schema=RawTextList, prompt=reasoning_prompt, system_instruction=( - "You are an AI engineering data reasoning engine. Your goal is to find missing data, " - "correct OCR errors, map misplaced attributes, and output clean structured JSON." + "You are an expert AI engineering data reasoning engine. Your objective is to achieve 100% extraction fidelity: " + "correct all OCR errors, restore dropped decimals, bind datasheet attributes, reject hallucinations, and output clean structured JSON." ), image_path=raw_image, provider=llm_provider, @@ -751,14 +760,24 @@ class SymbolRecognitionAgent(BaseAgent): elif not (local_mode or symbol_engine == "local"): prompt = ( - f"You are an expert industrial vision detector specializing in ISA-5.1 and engineering symbol recognition for {dt_label} drawings.\n" - f"Identify all graphical component symbols present in this drawing image.\n\n" - f"SYMBOL TAXONOMY VOCABULARY:\n {symbol_vocab}\n\n" - "FOR EACH DETECTED SYMBOL PROVIDE:\n" - " 1. symbol_type: The exact symbol classification from the taxonomy vocabulary.\n" - " 2. inferred_tag: Nearest readable tag number/ID (e.g., 26CB9131, PIT-9055, DB-01, EP-01) if visible nearby.\n" - " 3. ymin, xmin, ymax, xmax: Normalized bounding box coordinates between 0.0 and 1.0.\n\n" - "Return the list of detected symbols in structured JSON format." + f"You are a computer vision specialist in ISA-5.1 industrial symbol taxonomy and electrical schematics for {dt_label} drawings.\n\n" + "OBJECTIVE: Detect and localize all graphical components and symbols on the drawing canvas.\n\n" + f"AUTHORIZED SYMBOL VOCABULARY:\n {symbol_vocab}\n\n" + "MORPHOLOGICAL SYMBOL RECOGNITION RULES:\n" + " • CHECK_VALVE: Two opposing triangles or a directional flap/arrowhead across a seat.\n" + " • GATE_VALVE: Two opposing triangles touching at vertex along a pipeline.\n" + " • BALL_VALVE: Opposing triangles with a solid black/filled circle at center.\n" + " • GLOBE_VALVE: Opposing triangles with an open circle at center.\n" + " • CONTROL_VALVE: Valve body attached to a top pneumatic diaphragm/dome or motor actuator.\n" + " • PSV / SAFETY_VALVE: Angled body with inlet on run and discharge elbow to header with spring bonnet.\n" + " • INST_BUBBLE: Circular bubbles (field mounted = plain circle, control room = horizontal line across circle).\n" + " • STRAINER: Y-shaped branch casing or in-line bucket strainer body (e.g. 26-ST-9002).\n" + " • EQUIPMENT: Major vessels, compressors (trapezoidal profile), pumps (circular impeller casing), heat exchangers.\n\n" + "FOR EACH DETECTED SYMBOL:\n" + " 1. symbol_type: Must match one authorized classification from the vocabulary.\n" + " 2. inferred_tag: Associated adjacent tag label (e.g. 26CB9131, 26-KA-902, 26-ST-9002) if legible.\n" + " 3. ymin, xmin, ymax, xmax: Normalized bounding box [0.0 to 1.0] tightly enclosing the symbol icon.\n\n" + "Return the full symbol inventory in structured JSON format conforming to RawSymbolList." ) try: @@ -931,17 +950,23 @@ class PipelineRecognitionAgent(BaseAgent): # Option B: Full Multimodal VLM Polyline Tracer or Hybrid CV + VLM elif not (local_mode or pipeline_engine == "proximity_tracer"): prompt = ( - f"You are an expert topological pipeline and electrical connectivity tracer analyzing a {dt_label} drawing.\n\n" - "TASK 1 — TOPOLOGICAL RELATIONSHIPS:\n" - "Extract source→target connectivity pairs:\n" - " - MONITORS: Instrument or sensor monitoring a line or equipment.\n" - " - INSTALLED_ON: Valve or fitting installed on a line run.\n" - " - CONNECTS_TO: Pipe, busbar, or cable connecting two pieces of equipment.\n" - " - FEEDS: Distribution panel or switchboard feeding a circuit or breaker.\n" - " - EARTHED_TO: Equipment grounded to an earth bar or earth pit.\n\n" - "TASK 2 — GEOMETRY & SHEET GRIDS:\n" - "List the border grid sector designations (e.g., A1, B5, C9, D10) and trace any named piping runs or cable routes.\n\n" - "Return all findings in structured JSON format." + f"You are a principal process piping and electrical systems engineer analyzing topological connectivity on a {dt_label} drawing.\n\n" + "TASK 1 — TOPOLOGICAL CONNECTIVITY & STREAM GRAPH GENERATION:\n" + "Extract exact [source_tag] -> [target_tag] relationships adhering to physical flow directionality:\n" + " - INSTALLED_ON: In-line valves, check valves, control valves, strainers, or PSVs installed along a specific piping line.\n" + " (Example: '26CB9131' INSTALLED_ON '8\"-PV-26-9035-FC11S-08', 'PSV-9027A' INSTALLED_ON '10\"-VF-43-9027-AS20S-00').\n" + " *CRITICAL*: PSVs are installed on host process piping lines, NEVER arbitrarily mapped to distant vessels or coalescers.\n" + " - RELIEVES_TO: PSV discharge routing to flare or atmospheric relief headers (e.g. 'PSV-9027A' RELIEVES_TO 'HP Flare Header').\n" + " - DRAINS_TO: Equipment drains and low-point purges routing to drain headers (e.g. '26-HA-911' DRAINS_TO 'CLOSED DRAIN').\n" + " - MONITORS: Instrument sensors tapping into process lines or equipment nozzles (e.g. '26-PIT-9077' MONITORS '8\"-PV-26-9035-FC11S-08').\n" + " - CONNECTS_TO: Continuous process piping connecting source equipment nozzles to destination equipment nozzles.\n" + " - FEEDS: Power distribution switchgear, MDBs, or panels feeding electrical branch circuits or loads.\n" + " - EARTHED_TO: Equipment or structures connected via bonding tape to earth bars or earth pits.\n\n" + "DIRECTIONALITY CONSTRAINTS:\n" + " - FLARE, HP FLARE, LP FLARE, CLOSED DRAIN, OPEN DRAIN, ATMOSPHERE, VENT, and SUMP are TERMINAL SINKS (must always be targets, never sources feeding process units).\n\n" + "TASK 2 — GEOMETRY & SHEET BORDER GRIDS:\n" + "Identify border grid sector designations (e.g., A1, B5, C9, D10) and trace continuous polyline coordinates for all major process streams.\n\n" + "Return all findings as validated JSON conforming to the RawPipelineList schema." ) try: diff --git a/src/agents/re_extractor.py b/src/agents/re_extractor.py index 7c25c2f..ea2898a 100644 --- a/src/agents/re_extractor.py +++ b/src/agents/re_extractor.py @@ -180,14 +180,20 @@ class ReExtractorAgent(BaseAgent): logger.warning(f"Local mode: No items found in crop for {target}. Using heuristic fallback.") else: system_instruction = ( - "You are an engineering scanner focusing on drawing sub-crops. " - "Your job is to read blurry or tiny labels next to symbols that were " - "missed in the full layout scan." + "You are an expert high-magnification engineering visual inspector. " + "Your objective is to examine zoomed-in sub-crops of dense P&ID or electrical drawings, " + "resolving blurry, dense, or fragmented tags and validating missing in-line symbols and valve types." ) prompt = ( - f"Examine this visual crop. We are missing details for a component suspect of tag '{target}'. " - f"Reason: {reason}. Extract the exact tag name, symbol type, description, and spec info." + f"Perform high-resolution forensic inspection on this image crop around suspect tag/symbol '{target}'.\n\n" + f"Inspection Trigger: {reason}\n\n" + "TASKS:\n" + "1. Read the complete alphanumeric tag ID without character dropouts (e.g., check for dense valve numbers like 26CB9131 or 26GB9178).\n" + "2. Identify the exact ISA symbol type (Gate Valve, Check Valve, Ball Valve, Control Valve, PSV, Instrument Bubble, Strainer).\n" + "3. Capture associated physical parameters (line size, ANSI rating class 150#/2500#, set pressure bar(g), or electrical rating).\n" + "4. Trace local host line attachment.\n\n" + "Return the extracted items conforming to ReExtractionPayload." ) if crop_path and os.path.exists(crop_path): diff --git a/src/agents/supervisor.py b/src/agents/supervisor.py index 6935f13..42852c9 100644 --- a/src/agents/supervisor.py +++ b/src/agents/supervisor.py @@ -87,13 +87,19 @@ class SupervisorAgent(BaseAgent): Invokes Vision API to identify layout margins and divide the drawing. """ system_instruction = ( - "You are an expert design engineer. Analyze the border grids of the P&ID drawing sheet " - "and segment the drawing layout into structured region cells." + "You are a master engineering drawing layout analyst. " + "Examine the spatial architecture of this engineering drawing sheet and segment it into " + "discrete functional zones (high-density process canvas, equipment datasheet/table blocks, " + "symbol legend, drawing notes/revisions, and title block)." ) prompt = ( - "Look at the drawing boundaries. Identify the normalized bounding boxes [ymin, xmin, ymax, xmax] " - "for the three major grid cells containing high-density equipment/lines, legend region, and title block region." + "Partition the drawing canvas into normalized bounding boxes [ymin, xmin, ymax, xmax] (0.0 to 1.0):\n" + "1. Process Canvas / Main Schematic: The primary central drawing area containing equipment, piping, instruments, and circuits.\n" + "2. Equipment Datasheet / Parameter Blocks: Tabular parameter blocks containing engineering design specs (duty, flow, pressure, temperature, materials).\n" + "3. Legend & General Notes: Area containing symbol definitions, line type legends, and numbered project notes.\n" + "4. Title Block: Bottom-right metadata block with drawing number, client, project title, and revision history.\n\n" + "Return the localized grid coordinate regions conforming to LayoutSegmentation." ) try: