# Precision Branch Regression Report **Engineering Drawing Intelligence System (MTO2Doc)** **Target Drawing:** `pid_stuff/Lift Gas compressor-PID.pdf` **Execution Date:** September 30, 2026 --- ## 1. Test Execution Summary | Test Suite | Commands Executed | Tests Collected | Passed | Failed | Execution Time | Status | | :--- | :--- | :---: | :---: | :---: | :---: | :---: | | **Pytest Full Suite** | `pytest tests/` | 60 | 60 | 0 | 10.41s | **100% PASS** | | **Valve & Line Accuracy** | `python tests/test_valve_line_accuracy.py` | 43 | 43 | 0 | 11.23s | **100% PASS** | | **Ground Truth Precision** | `python scratch_compute_precision.py` | 104 GT Entities | 104 TP | 0 FN | 13.56s | **100% PASS** | --- ## 2. Regression Analysis by Test Category ### A. Tag Parsing & OCR Rectification - Stitched 3-fragment lines: `8"-PV-26-9035-FC11S-08` [PASS] - Split valve tags: `HV-` + `101` $\rightarrow$ `HV-101` [PASS] - OCR typo rectification (`B"` $\rightarrow$ `8"`, `l/2"` $\rightarrow$ `1/2"`, `FC115` $\rightarrow$ `FC11S`): [PASS] - Dense manual valve classification (`26GB9178`, `26CB9131` as `VALVE_TAG`): [PASS] ### B. Dual-Anchor Hybrid Valve Compilation - Total compiled valves from mixed text + vision symbols: 4 valves [PASS] - Gate valve recognition and attribute inheritance: [PASS] - Size inheritance from host line (8"): [PASS] - Rating derivation from line spec (`FC11S` $\rightarrow$ `2500#`): [PASS] - Hand control valve classification (`HV-101`): [PASS] - Untagged check valve detection (`CB-SYM-01`): [PASS] - Geometrically associated gate valve (`GV-SYM-02`): [PASS] - Spec-to-ANSI class mapping (`GC11S` $\rightarrow$ `150#`): [PASS] ### C. Equipment Taxonomy & PSV Recovery - Coalescing filter separator (`26-CX-9122`): [PASS] - Compressor classification (`26-KA-901`): [PASS] - PSV unit number recovery (`Unit 26`): [PASS] - Relief destination assignment (`HP Flare Header`): [PASS] ### D. Advanced Pipeline Checks - Rejected hallucinated line with `-NOTE`: [PASS] - Rejected hallucinated line with `-TIT`: [PASS] - Rejected motor driver tag from Line List: [PASS] - Rejected transmitter cable tag from Line List: [PASS] - Reversal of inverted relation directions: [PASS] - Sibling instrument extraction (`27-PY-0001BA`, `27-PY-0001BB`): [PASS] - Suction strainer recognition (`26-CK-911` / `26-ST-9002`): [PASS] - Zero orphan instruments (Rule VAL-004): [PASS] --- ## 3. Ground Truth Recall Guarantee Baseline Recall was **96.15%**. Precision Branch Recall is **100.00%** (104 / 104). No ground truth entities were suppressed or dropped: - `26-CK-911` (Equipment Suction Strainer): Captured and compiled. - `26-PSE-9216` & `26-PSE-9758` (Rupture Discs): Captured and compiled into instruments. - `26-PSV-9066A` & `26-PSV-9066B` (Safety Relief Valves): Captured and compiled into safety relief valves. - `40-XV-9010` (Cooling Water Isolation Valve): Captured and compiled. - All 40 Manual Valves (`26BL9072` through `40GT9308`): Captured and compiled. - All 35 Process Lines (`1"-DC-57-9015` through `2"-VF-43-9032`): Captured and compiled. **Conclusion:** Zero regressions occurred. All perception recall capabilities have been preserved and expanded to 100% ground truth coverage.