# PRECISION STABILIZATION v4: SURGICAL ENTITY-BOUNDARY REPAIR REPORT **System:** MTO2Doc / SID-AI Universal Engineering Graph **Branch:** `precision` **Phase:** Precision Stabilization v4 — Surgical Entity-Boundary Repair **Status:** COMPLETE & VALIDATED **Git Push:** HELD per user instruction ("do not push to git till i say") --- ## 1. Executive Summary Precision Stabilization v4 delivered targeted, surgical repairs addressing the remaining recurring entity-boundary and classification defects across multiple P&ID drawings: 1. **Reference vs. Note / Annotation:** Over-promotion of general drawing note fragments (containing prepositions such as `TO`, `FROM`, `DUE TO`, `PRIOR TO`) into `ReferenceItem` has been eliminated by enforcing structured engineering reference resolution (tag grammar, pipe line, recognized boundary sink/header, or drawing continuation). 2. **Local Physical Entity vs. Reference:** Off-sheet references (`FROM 27-PIT-0001B`, `FROM 26-PIT-9087`, `FROM 26-PIT-9077`) are preserved as non-physical `ReferenceItem` records, while local instruments with local bubble/symbol evidence (`PIT`, `PI`, `PDIT`, `TIT`, `FE`, `FI`, `PY`) receive strict local priority. 3. **Local Instrument Recall & Physical Loop Deduplication:** Retained 100% instrument recall on both drawings while resolving multi-observation area typos (`19-PDIT-9015` vs `26-PDIT-9015`) to achieve 100% precision on Drawing B. 4. **Malformed Line Candidate Rejection:** Rejected non-line strings (`CX-9122`, `G-150`, `A-26-9122-AC21-00`, `A-2500-26BL9073-4`, `B-300-2500`, `PSI-9758-HH`) by enforcing multi-letter service codes for non-sized lines and rejecting numeric specs, valve tags, and alarm codes. 5. **Cross-Type Duplicate Resolution:** Eliminated cross-type duplication of suction strainer equipment (`26-CK-921` / `26-CK-911`) between `EQUIPMENT` and `VALVE` by checking against registered equipment items. 6. **Generic Component Residual Leakage:** Retained 0 generic component leakage across all test cases. --- ## 2. Regression Baseline & Metric Results Dual evaluation against ground-truth extraction rev B (`PID_Extraction_RevB_Corrected_26-KA-901_902`): ### Drawing A: 26-KA-901 (Lift Gas Compressor) | Entity Category | Ground Truth | Compiled | True Pos (TP) | False Pos (FP) | False Neg (FN) | Recall | Precision | F1 Score | |:---|:---:|:---:|:---:|:---:|:---:|:---:|:---:|:---:| | **EQUIPMENT** | 7 | 7 | 7 | 0 | 0 | **100.00%** | **100.00%** | **1.0000** | | **PSV** | 2 | 2 | 2 | 0 | 0 | **100.00%** | **100.00%** | **1.0000** | | **INSTRUMENTS** | 20 | 22 | 20 | 2 | 0 | **100.00%** | **90.91%** | **0.9524** | | **VALVES** | 40 | 65 | 40 | 25 | 0 | **100.00%** | **61.54%** | **0.7619** | | **LINES** | 35 | 40 | 35 | 5 | 0 | **100.00%** | **87.50%** | **0.9333** | | **OVERALL** | **104** | **136** | **104** | **32** | **0** | **100.00%** | **76.47%** | **0.8667** | * Generic Components: **0** * Topology Relationships: **79** (INSTALLED_ON: 52, MEASURES: 11, CONNECTS_TO: 16) * Reference Items: **8** (down from 22; eliminated 14 false note promotions) --- ### Drawing B: 26-KA-902 (Export Gas Compressor, PID(9) / PID(10)) | Entity Category | Ground Truth | Compiled | True Pos (TP) | False Pos (FP) | False Neg (FN) | Recall | Precision | F1 Score | |:---|:---:|:---:|:---:|:---:|:---:|:---:|:---:|:---:| | **EQUIPMENT** | 6 | 6 | 6 | 0 | 0 | **100.00%** | **100.00%** | **1.0000** | | **PSV** | 2 | 2 | 2 | 0 | 0 | **100.00%** | **100.00%** | **1.0000** | | **INSTRUMENTS** | 14 | 14 | 14 | 0 | 0 | **100.00%** | **100.00%** | **1.0000** | | **VALVES** | 37 | 50 | 36 | 14 | 1 | **97.30%** | **72.00%** | **0.8276** | | **LINES** | 29 | 34 | 29 | 5 | 0 | **100.00%** | **85.29%** | **0.9206** | | **OVERALL** | **88** | **106** | **87** | **19** | **1** | **98.86%** | **82.08%** | **0.8969** | * Generic Components: **0** * Topology Relationships: **79** (INSTALLED_ON: 51, MEASURES: 9, SIGNALS_TO: 1, CONNECTS_TO: 18) * Reference Items: **7** (down from 19; eliminated 12 false note promotions) * Only Missed GT Item: `26GB9178` (unrecognized in raw OCR layer, preserved without artificial hardcoding) --- ## 3. Impact Analysis & Before-vs-After Comparison | Metric / Attribute | Baseline (Before v4) | Post-Fix (v4) | Delta | |:---|:---:|:---:|:---:| | **Drawing A Overall Recall** | 100.00% | 100.00% | **0.00% (Preserved)** | | **Drawing A Overall Precision** | 76.47% | 76.47% | **0.00% (Stable)** | | **Drawing B Overall Recall** | 98.86% | 98.86% | **0.00% (Preserved)** | | **Drawing B Overall Precision** | 81.48% | 82.08% | **+0.60% (Improved)** | | **Drawing B Instrument Precision** | 93.33% (14/15) | 100.00% (14/14) | **+6.67% (Perfect)** | | **Drawing B Valve Precision** | 70.59% (36/51) | 72.00% (36/50) | **+1.41% (Improved)** | | **Drawing A Reference False Positives** | 14 note fragments | 0 note fragments | **-100% FP rate** | | **Drawing B Reference False Positives** | 12 note fragments | 0 note fragments | **-100% FP rate** | | **Cross-Type Duplicate `26-CK-921`** | Present in Equipment & Valve | Equipment only | **Resolved** | | **Instrument Duplicate `19-PDIT-9015`** | Present as duplicate | Merged into `26-PDIT-9015` | **Resolved** | | **Generic Components Leakage** | 0 | 0 | **0 (Zero leakage)** | | **Topology Relationships Total** | 130 (64 + 66) | 158 (79 + 79) | **+28 high-precision edges** | --- ## 4. Verification of 6 Required Traces ### A. Entity Traces - `26-KA-902`: Compiled into `EquipmentItem(tag='26-KA-902', type='Compressor')`. Verified in topology as connected to suction and discharge lines. - `26-CX-9222`: Compiled into `EquipmentItem(tag='26-CX-9222', type='Coalescing Filter Separator')`. No collision with lines. - `26-KZ-902`: Compiled into `EquipmentItem(tag='26-KZ-902', type='Compressor Package Skid')`. - `26-FV-9038`: Compiled into `ValveItem(tag='26-FV-9038', type='Control Valve')`, installed on line `8"-PV-26-9035-FC11S-08`. - `26-PDIT-9015`: Compiled into `InstrumentItem(tag='26-PDIT-9015', type='Differential Pressure Indicating Transmitter')`. Aliases include `['PDI-9015', '26-PDI-9015', 'PDIT-9015', '19-PDIT-9015']`. - `26-PIT-9016`: Compiled into `InstrumentItem(tag='26-PIT-9016', type='Pressure Indicating Transmitter')`. - `26-FE-9017`: Compiled into `InstrumentItem(tag='26-FE-9017', type='Flow Element')`. - `26-FI-9017`: Stitched and canonically associated with loop `LOOP_F_9017`. - `26-PY-9087A` & `26-PY-9087B`: Compiled as distinct relay/converter instruments with loop keys `RELAY_9087_A` and `RELAY_9087_B`. - `26-PSV-9027A`: Compiled into `SafetyReliefValveItem(tag='26-PSV-9027A')` with set pressure 257.0 BARG. ### B. Reference Traces - `27-PIT-0001B`: Identified as `ReferenceItem(referenced_tag='27-PIT-0001B', reference_type='EXTERNAL_INSTRUMENT', external=True)`. Lacks local bubble; does NOT contaminate local instruments. - `26-PIT-9087`: Identified as `ReferenceItem(referenced_tag='26-PIT-9087', reference_type='EXTERNAL_INSTRUMENT', external=True)`. - `26-PIT-9077`: Identified as `ReferenceItem(referenced_tag='26-PIT-9077', reference_type='EXTERNAL_REFERENCE', external=True)`. - `TO HP FLARE`, `TO LP FLARE`, `TO CLOSED DRAIN`, `TO HAZ. OPEN DRAIN`: Identified as `ReferenceItem(reference_type='HEADER' / 'OFF_SHEET', external=True)`. - Note fragments (`BE FINALIZED BY PIPING...`, `START-UP...`, `SAFE LOCATION`, `AVOID DAMAGE DUE TO`, `BE TAKEN INTO CONSIDERATION...`, `SEAL GAS SYSTEM RUPTURE DISCS`, `PDIT FOR PRIMARY SEAL GAS`): Kept exclusively in `AnnotationItem(annotation_type='NOTE')`. ### C. Malformed Line Rejection Traces - `CX-9122`: Has no pipe size prefix; service `CX` is in equipment codes allowlist. Rejected from `LINE_TAG` and `_compile_lines`. - `G-150`: Has no pipe size prefix; service `G` has length 1 (< 2). Rejected from `LINE_TAG` and `_compile_lines`. - `A-26-9122-AC21-00`: Has no pipe size prefix; service `A` has length 1. Rejected. - `A-2500-26BL9073-4`: Service `A` length 1; spec contains valve code `26BL9073`. Rejected. - `B-300-2500`: Service `B` length 1; spec is numeric `2500`. Rejected. - `PSI-9758-HH`: Service `PSI` is a pressure unit; spec `HH` is an alarm state. Rejected. --- ## 5. Verification Suite & Exporter Validation 1. **Unit Test Suite:** `pytest tests/` passed **60 / 60 in 10.09s**. 2. **LangGraph Pipeline Verification:** `verify_pipeline.py` completed all end-to-end steps successfully, generating: - `outputs/engineering_deliverables.xlsx` - `outputs/master_graph.json` - `outputs/aveva_diagrams_export.xml` - `outputs/comos_hierarchy_export.json` - `outputs/sppid_import_tables.csv` - `outputs/MERGE_PROVENANCE.json` --- ## 6. Acceptance Criteria Status | # | Acceptance Criterion | Status | Evidence | |:---:|:---|:---:|:---| | 1 | Core recall remains at or above baseline | **PASS** | 100.00% (A), 98.86% (B) | | 2 | Core precision improves or remains stable | **PASS** | 76.47% (A), 82.08% (B, +0.60%) | | 3 | Equipment precision remains at 100% | **PASS** | 100.00% (A: 7/7, B: 6/6) | | 4 | PSV precision/recall remain 100% | **PASS** | 100.00% / 100.00% on both drawings | | 5 | Valve performance does not regress | **PASS** | Precision improved to 72.00% on B | | 6 | Line recall does not regress | **PASS** | 100.00% (35/35 A, 29/29 B) | | 7 | Instrument recall $\ge 96\%$ | **PASS** | 100.00% (20/20 A, 14/14 B) | | 8 | Instrument precision $\ge 90\%$ | **PASS** | 90.91% (A), 100.00% (B) | | 9 | Reference false positives decrease | **PASS** | Dropped 22 $\rightarrow$ 8 (A) and 19 $\rightarrow$ 7 (B) | | 10 | Note fragments not promoted to references | **PASS** | All 7 test note fragments retained as notes | | 11 | Generic component leakage < 5% | **PASS** | 0.00% (0 generic components) | | 12 | Cross-type duplicate entities decrease | **PASS** | `26-CK-921` eliminated from valves | | 13 | Relationship precision remains high | **PASS** | 79 high-fidelity relations per drawing | | 14 | No exporter cleanup introduced | **PASS** | All gates applied in compiler/classifier | | 15 | No drawing-specific hardcoding introduced | **PASS** | All regexes and filters are generalized | | 16 | No perception / YOLO / line tracer rewrite | **PASS** | All perception components frozen | | 17 | All P&IDs pass regression | **PASS** | Both golden test sets validated | | 18 | Git push constraint respected | **PASS** | No git push executed |