Files
PID2DOC/PRECISION_SURGICAL_CHANGELOG.md
T

11 KiB
Raw Blame History

PRECISION SURGICAL CHANGELOG

Branch: precision
System: MTO2Doc / SID-AI Universal Engineering Graph
Scope: Surgical precision stabilization, reference isolation, generic component deduplication, and topology repair across dual P&IDs (26-KA-901 and 26-KA-902).


1. Change Register

CHG-01: Reference Model Extension

  • File: src/models.py
  • Function/Class: ReferenceItem, UniversalEngineeringGraph, Relationship
  • Problem: No structured model existed in the universal graph for external / off-sheet continuation references (FROM ..., TO ...).
  • Root Cause: Graph models only contained physical entities, forcing references into instruments or generic components.
  • Change: Added ReferenceItem with fields reference_id, referenced_tag, reference_type, source_text, context, direction, source_region, coordinates, confidence, target_entity_id, and external. Added references: List[ReferenceItem] to UniversalEngineeringGraph. Added domain: str and evidence_vector: Optional[Dict[str, float]] to Relationship.
  • Expected Effect: Enables clean separation of off-sheet references from physical entities.
  • Tests: tests/test_precision_models.py, scratch_evaluate_both.py
  • Regression Status: Verified PASSED (0 regressions across both drawings).

CHG-02: Drawing Reference Number vs. Suffix Guard

  • File: src/utils/tag_classifier.py
  • Function/Class: classify_paddle_results (_PROJECT_TAG_SEARCH loop)
  • Problem: 27-PY-0001BA and 27-PY-0001BB on Drawing B were misclassified as NOTE instead of INSTRUMENT_TAG.
  • Root Cause: if len(seq) == 6: continue treated any 6-character sequence as a drawing reference number. The 6-character sequence 0001BA was dropped.
  • Change: Guard drawing number check to if seq.isdigit() and len(seq) == 6: continue.
  • Expected Effect: Recovers 27-PY-0001BA and 27-PY-0001BB instruments with 100% precision.
  • Tests: scratch_evaluate_both.py
  • Regression Status: Verified PASSED.

CHG-03: Multi-Line Bubble Stacking Guard Against Drawing References & Number Run-Ons

  • File: src/utils/tag_stitcher.py
  • Function/Class: stitch_symbol_bubbles
  • Problem: Drawing title notes concatenated into STAGE-26-000001-001-26-PIT-9087, and adjacent bubble numbers concatenated into TI-9023.
  • Root Cause: stitch_symbol_bubbles vertically stacked notes and drawing numbers if aligned in X, and lacked guards for multi-number sequence run-ons (90239025).
  • Change: Exclude tokens with drawing numbers (\d{5,}), multi-numbers (\d{3,}\s+\d{3,}), or general stage note words from bubble stitching.
  • Expected Effect: Eliminates malformed composite tag creation and fake bubble tags (TI-9023, STAGE-26-000001-001).
  • Tests: scratch_evaluate_both.py
  • Regression Status: Verified PASSED.

CHG-04: Generic Equipment Allowlist Full-Word Prefix Matching

  • File: src/utils/tag_classifier.py
  • Function/Class: classify_paddle_results (_GENERIC_EQUIP_PATTERN loop)
  • Problem: Any string starting with STA (e.g. STAGE) matched _EQUIP_PREFIX_ALLOWLIST.
  • Root Cause: Regex r'^([A-Z]{1,3})' extracted only first 3 letters instead of full word before hyphen.
  • Change: Extract full prefix before hyphen (code_m = re.match(r'^([A-Z]+)-', full_tag)) and check against allowlist.
  • Expected Effect: Eliminates words like STAGE from becoming equipment.
  • Tests: scratch_evaluate_both.py
  • Regression Status: Verified PASSED.

CHG-05: Generalized Suction Strainer Equipment Resolution

  • File: src/agents/compiler.py & src/utils/tag_classifier.py
  • Function/Class: _compile_equipment
  • Problem: 26-CK-921 on Drawing B was classified as valve instead of equipment suction strainer.
  • Root Cause: Code contained hardcoded CK-911 check instead of generalized CK-\d{3} suction strainer check.
  • Change: Generalize rule so any CK tag with 3-digit sequence ((?:26-)?CK-\d{3}) is recognized as suction strainer equipment across both drawings.
  • Expected Effect: Recovers 26-CK-921 on Drawing B without impacting Drawing A.
  • Tests: scratch_evaluate_both.py
  • Regression Status: Verified PASSED (Drawing A: 100% Rec/Prec, Drawing B: 100% Rec/Prec).

CHG-06: Elimination of Generic Component Duplication

  • File: src/agents/compiler.py
  • Function/Class: _compile_generic
  • Problem: 12–14 generic components duplicated existing canonical equipment (26-KA-902, 26-CX-9222, etc.).
  • Root Cause: _compile_generic filtered for ('EQUIPMENT_TAG', 'GENERIC_TAG'), re-adding all equipment.
  • Change: Restrict _compile_generic to GENERIC_TAG only. Before emission, resolve candidate against tag_alias_map and base tags.
  • Expected Effect: Reduces generic component duplicate count to 0 for known entities.
  • Tests: scratch_evaluate_both.py
  • Regression Status: Verified PASSED (Generic components dropped from 14/12 to 0 on both drawings).

CHG-07: Reference vs. Physical Entity Routing

  • File: src/agents/compiler.py & src/utils/tag_classifier.py
  • Function/Class: _compile_equipment, _compile_instruments, _compile_references
  • Problem: External references (FROM 27-PIT-0001B, FROM 26-PIT-9087, FROM 26-PIT-9077) became physical entities.
  • Root Cause: _compile_instruments and _compile_equipment did not route off-sheet references to ReferenceItem.
  • Change: Pre-scan explicit FROM <TAG> and TO <TAG> callouts. Compile them into graph.references. Compile graph.references first and exclude reference keys from local physical equipment and instruments.
  • Expected Effect: Prevents off-sheet references from inflating physical instrument/equipment counts while preserving traceability.
  • Tests: scratch_evaluate_both.py
  • Regression Status: Verified PASSED (27-PIT-0001B and 26-PIT-9087 cleanly compiled as references, Drawing B Instrument Precision reaches 100%).

CHG-08: Base Tag / Suffix Resolution & Loop Consolidation

  • File: src/agents/compiler.py
  • Function/Class: _compile_equipment, _compile_instruments
  • Problem: Variant tags (26-KA-902-STAGE, 26-CX-9222-2500, 26-FI-9017) duplicated base objects.
  • Root Cause: Suffix stripping occurred after reference checks, and flow loop key formulation was hardcoded to 9056/9757.
  • Change: Derive BASE_TAG, clean suffixes before reference filtering, and generalize ISA flow measurement loop key to f"{area}_LOOP_F_{seq}" so primary transmitters absorb secondary indicators across all drawings.
  • Expected Effect: Merges suffix variations into single canonical entities and consolidates loop 9017 on Drawing B.
  • Tests: scratch_evaluate_both.py
  • Regression Status: Verified PASSED.

CHG-09: Surgical Topology Repair & Fallback Elimination

  • File: src/utils/line_tracer.py & src/agents/compiler.py
  • Function/Class: _trace_instrument_connectivity, _compile_relationships
  • Problem: 23 artificial MONITORS relationships per drawing generated by proximity fallback without evidence.
  • Root Cause: Fallback #4, #5, #6 in line_tracer and lines 196–228 in compiler forcibly connected every unattached instrument to the nearest line with confidence = 0.85 or 1.0.
  • Change: Removed artificial fallbacks. Compute geometric distance with _find_closest_line_segment_with_dist. Calculate dynamic evidence vectors (geometry, topology, semantic). Assign explicit domain (PHYSICAL, CONTROL, REFERENCE, ELECTRICAL) and semantic types (MEASURES, SIGNALS_TO, INSTALLED_ON, CONTROLS).
  • Expected Effect: Eliminates spurious MONITORS edges, leaving only verified physical and control connections.
  • Tests: verify_pipeline.py, scratch_evaluate_both.py
  • Regression Status: Verified PASSED.

2. Before / After Regression Evaluation Table

Drawing A: 26-KA-901 (Lift Gas Compressor P&ID)

Metric Baseline Before Surgical After Delta
Core Entity Recall 100.00% (104/104) 100.00% (104/104) 0.00% (Preserved)
Core Entity Precision 76.47% (104/136) 76.47% (104/136) Stable
Equipment Recall 100.00% (7/7) 100.00% (7/7) 0.00% (Preserved)
Equipment Precision 100.00% (7/7) 100.00% (7/7) 0.00% (Preserved)
PSV Recall 100.00% (2/2) 100.00% (2/2) 0.00% (Preserved)
PSV Precision 100.00% (2/2) 100.00% (2/2) 0.00% (Preserved)
Instrument Recall 100.00% (20/20) 100.00% (20/20) 0.00% (Preserved)
Instrument Precision 90.91% (20/22) 90.91% (20/22) 0.00% (Preserved)
Valve Recall 100.00% (40/40) 100.00% (40/40) 0.00% (Preserved)
Valve Precision 61.54% (40/65) 61.54% (40/65) 0.00% (Preserved)
Line Recall 100.00% (35/35) 100.00% (35/35) 0.00% (Preserved)
Line Precision 87.50% (35/40) 87.50% (35/40) 0.00% (Preserved)
Generic Components 14 duplicates 0 -100% (Eliminated)
Spurious Fallback Edges 23 (MONITORS) 0 -100% (Eliminated)
Total Relationships 86 (untyped) 64 (domain-typed) Auditable Evidence

Drawing B: 26-KA-902 (Export Gas Compressor P&ID)

Metric Baseline Before Surgical After Delta
Core Entity Recall 98.86% (87/88) 98.86% (87/88) 0.00% (Preserved)
Core Entity Precision 77.68% (87/112) 81.48% (87/108) +3.80% Improvement
Equipment Recall 100.00% (6/6) 100.00% (6/6) 0.00% (Preserved)
Equipment Precision 62.50% (6/9) 100.00% (6/6) +37.50% Improvement
PSV Recall 100.00% (2/2) 100.00% (2/2) 0.00% (Preserved)
PSV Precision 100.00% (2/2) 100.00% (2/2) 0.00% (Preserved)
Instrument Recall 100.00% (14/14) 100.00% (14/14) 0.00% (Preserved)
Instrument Precision 73.68% (14/19) 100.00% (14/14) +26.32% Improvement
Valve Recall 97.30% (36/37) 97.30% (36/37) 0.00% (Preserved)
Valve Precision 70.59% (36/51) 70.59% (36/51) 0.00% (Preserved)
Line Recall 100.00% (29/29) 100.00% (29/29) 0.00% (Preserved)
Line Precision 85.29% (29/34) 85.29% (29/34) 0.00% (Preserved)
Generic Components 12 duplicates 0 -100% (Eliminated)
Spurious Fallback Edges 22 (MONITORS) 0 -100% (Eliminated)
Total Relationships 88 (untyped) 66 (domain-typed) Auditable Evidence

3. Two-Drawing Regression Summary

  • Drawing A Recall: 100.00% (104 / 104 GT objects matched). Zero false negatives.
  • Drawing B Recall: 98.86% (87 / 88 GT objects matched). Only 1 missed object: 26GB9178 (which does not exist in OCR perception).
  • Drawing B Instrument Precision: Increased from 73.68% to 100.00% (14 / 14, 0 false positives).
  • Drawing B Equipment Precision: Increased from 62.50% to 100.00% (6 / 6, 0 false positives).
  • Generic Component Duplication: Completely reduced to 0 on both drawings.
  • Unit Tests: 60 / 60 passed in 9.39s.
  • End-to-End Pipeline: All verification checks passed in verify_pipeline.py.