Files
PID2DOC/PRECISION_REGRESSION_REPORT.md
T
Abhinav Gupta c28be21557 feat(precision): achieve 100% ground truth recall and 76.47% entity precision
- Add centralized ISA 5.1/ISO 15926 taxonomy and DecomposedTag model
- Implement multi-evidence candidate scoring and explainable merge provenance
- Refine CompilerAgent: ISA loop consolidation, dense valve formatting, cross-system isolation
- Enforce canonical endpoint strictness for relationships (zero raw OCR strings)
- Update ValidationAgent with structured actionable feedback
- Add comprehensive test suites (60 pytest + 43 hybrid tests passing 100%)
- Generate baseline, regression, validation, confusion matrix, and final audit reports
2026-09-30 12:00:27 +05:30

3.2 KiB

Precision Branch Regression Report

Engineering Drawing Intelligence System (MTO2Doc)
Target Drawing: pid_stuff/Lift Gas compressor-PID.pdf
Execution Date: September 30, 2026


1. Test Execution Summary

Test Suite Commands Executed Tests Collected Passed Failed Execution Time Status
Pytest Full Suite pytest tests/ 60 60 0 10.41s 100% PASS
Valve & Line Accuracy python tests/test_valve_line_accuracy.py 43 43 0 11.23s 100% PASS
Ground Truth Precision python scratch_compute_precision.py 104 GT Entities 104 TP 0 FN 13.56s 100% PASS

2. Regression Analysis by Test Category

A. Tag Parsing & OCR Rectification

  • Stitched 3-fragment lines: 8"-PV-26-9035-FC11S-08 [PASS]
  • Split valve tags: HV- + 101 \rightarrow HV-101 [PASS]
  • OCR typo rectification (B" \rightarrow 8", l/2" \rightarrow 1/2", FC115 \rightarrow FC11S): [PASS]
  • Dense manual valve classification (26GB9178, 26CB9131 as VALVE_TAG): [PASS]

B. Dual-Anchor Hybrid Valve Compilation

  • Total compiled valves from mixed text + vision symbols: 4 valves [PASS]
  • Gate valve recognition and attribute inheritance: [PASS]
  • Size inheritance from host line (8"): [PASS]
  • Rating derivation from line spec (FC11S \rightarrow 2500#): [PASS]
  • Hand control valve classification (HV-101): [PASS]
  • Untagged check valve detection (CB-SYM-01): [PASS]
  • Geometrically associated gate valve (GV-SYM-02): [PASS]
  • Spec-to-ANSI class mapping (GC11S \rightarrow 150#): [PASS]

C. Equipment Taxonomy & PSV Recovery

  • Coalescing filter separator (26-CX-9122): [PASS]
  • Compressor classification (26-KA-901): [PASS]
  • PSV unit number recovery (Unit 26): [PASS]
  • Relief destination assignment (HP Flare Header): [PASS]

D. Advanced Pipeline Checks

  • Rejected hallucinated line with -NOTE: [PASS]
  • Rejected hallucinated line with -TIT: [PASS]
  • Rejected motor driver tag from Line List: [PASS]
  • Rejected transmitter cable tag from Line List: [PASS]
  • Reversal of inverted relation directions: [PASS]
  • Sibling instrument extraction (27-PY-0001BA, 27-PY-0001BB): [PASS]
  • Suction strainer recognition (26-CK-911 / 26-ST-9002): [PASS]
  • Zero orphan instruments (Rule VAL-004): [PASS]

3. Ground Truth Recall Guarantee

Baseline Recall was 96.15%.
Precision Branch Recall is 100.00% (104 / 104).
No ground truth entities were suppressed or dropped:

  • 26-CK-911 (Equipment Suction Strainer): Captured and compiled.
  • 26-PSE-9216 & 26-PSE-9758 (Rupture Discs): Captured and compiled into instruments.
  • 26-PSV-9066A & 26-PSV-9066B (Safety Relief Valves): Captured and compiled into safety relief valves.
  • 40-XV-9010 (Cooling Water Isolation Valve): Captured and compiled.
  • All 40 Manual Valves (26BL9072 through 40GT9308): Captured and compiled.
  • All 35 Process Lines (1"-DC-57-9015 through 2"-VF-43-9032): Captured and compiled.

Conclusion: Zero regressions occurred. All perception recall capabilities have been preserved and expanded to 100% ground truth coverage.