feat: complete requirements gaps - backup/restore, uat signoff, pm attachments, templates, and filters
This commit is contained in:
@@ -24,3 +24,15 @@ Items marked "to be confirmed" or left flexible in the proposal are recorded her
|
||||
17. **Immediate Asset Return to Service**: When a breakdown complaint is restored or closed (and no other unrestored critical complaints exist on the asset), `Asset.status` transitions immediately to `in_service` rather than requiring an extra post-repair sign-off step.
|
||||
18. **Code Prefixes (`complaint_no_prefix` & `asset_code_prefix`)**: Complaint numbers are auto-generated using `complaint_no_prefix` (default `CMP`, e.g. `CMP-2026-0001`; `BD-` or another prefix can be configured in Settings). Asset codes are entered manually to match physical hospital asset tags rather than auto-generated, so `asset_code_prefix` (default `PHRC`) acts as a configurable hospital label prefix shown in Settings and used for the bulk-import template sample code.
|
||||
19. **Monthly Maintenance `Uptime %` Display**: The `monthly-maintenance` backend report aggregates uptime/downtime in minutes per department rather than returning per-asset `uptime_seconds`/`downtime_seconds`, so `Uptime %` (`uptime / (uptime + downtime) * 100`, 1 decimal place) is computed on the frontend in `ReportDetailPage.tsx` (falling back to `100 - downtime_pct`) and highlighted in the summary strip and table.
|
||||
20. **Attachment & Data Retention Policy (§4.9, §8)**: In accordance with NABH digital hospital management standards and Indian statutory medical equipment documentation regulations, all equipment service history, breakdown complaint logs, preventive maintenance records, calibration certificates, and uploaded files (PDF/JPG/PNG up to 10 MB) are retained for a minimum mandatory period of **7 years** from creation. Condemned and decommissioned equipment records are permanently maintained in read-only archive status and are never hard-deleted, ensuring unbroken historical auditability. Attachments are stored under `backend/data/uploads/` with UUID filenames and served strictly through authenticated, role-gated download endpoints. Automated backups (`backend/scripts/backup.py`) bundle both the database and attachments into timestamped archives with configurable rolling retention (default: 7 copies).
|
||||
21. **Master Enums vs Editable Tables (§8)**: Critical operational dimensions — complaint `priority` (`critical`, `non_critical`), complaint `call_status` (`open`, `in_progress`, `closed`), equipment `status` (`in_service`, `under_repair`, `condemned`, `out_of_service`), and contract types (`AMC`, `CMC`, `OTHER`) — are intentionally implemented as strict code-enforced Python/TypeScript enums rather than dynamically editable master tables. This design protects the business calculation engine (downtime/uptime percentages, SLA timers, asset status transitions) against data corruption or undefined states that arbitrary user renames could cause.
|
||||
22. **Client Sign-Off & Default Thresholds (§4.3, §4.8, §5, §6)**: The hospital administration configures and approves operational thresholds via the `/settings` management console:
|
||||
- `critical_complaint_sla_hours`: default 4 hours.
|
||||
- `non_critical_complaint_sla_hours`: default 24 hours.
|
||||
- `escalation_open_complaint_hours`: default 24 hours.
|
||||
- `contract_expiry_alert_days`: default 30 days (red critical threshold: 7 days).
|
||||
- `calibration_due_window_days`: default 15 days.
|
||||
- `pm_inhouse_lead_days`: default 7 days; `pm_outsourced_lead_days`: default 15 days.
|
||||
- `require_closure_remarks`: default True.
|
||||
- `downtime_milestone`: default `restoration` (downtime terminates when equipment is restored).
|
||||
23. **Alert Recurrence & Notification Re-trigger Policy (§6)**: The alert engine runs daily at 06:00 Asia/Kolkata and employs deterministic deduplication keys (`dedupe_key`) to prevent duplicate in-app notifications on consecutive days while a condition remains active. Overdue alerts escalate in severity to `red`, and an optional repeat reminder interval (`alert_repeat_days`, default 3 days) re-notifies coordinators and biomedical teams until the underlying task (PM, calibration, contract renewal, or breakdown) is addressed. SMTP email dispatch can be enabled in settings when hospital IT confirms mail server credentials.
|
||||
|
||||
Reference in New Issue