# Project Status: Warehouse Robot Fleet Digital Twin **Last Updated**: October 21, 2026 **Current Phase**: **Phase 5: Charging and Operational Constraints (COMPLETED)** **Status**: Ready for User Review and Approval --- ## 1. Phase Tracker | Phase | Description | Status | Test Coverage | | :--- | :--- | :--- | :--- | | **Phase 0** | **Environment and project foundation** | **COMPLETED** | **17 passed** | | **Phase 1** | **Warehouse model** | **COMPLETED** | **26 passed** | | **Phase 2** | **Robot and task models** | **COMPLETED** | **56 passed** | | **Phase 3** | **Discrete-event simulation** | **COMPLETED** | **72 passed** | | **Phase 4** | **Routing and fleet assignment** | **COMPLETED** | **95 passed** | | **Phase 5** | **Charging and operational constraints** | **COMPLETED** | **110 passed (100%)** | | Phase 6 | Analytics and experiment framework | Planned (Next) | - | | Phase 7 | Omniverse USD visualization | Planned | - | | Phase 8 | Operational dashboard | Planned | - | | Phase 9 | Optimization and final demonstration | Planned | - | --- ## 2. Completed Tasks (Phase 5) - [x] Implemented Physics-Informed Battery Model (`src/warehouse_twin/fleet/battery_model.py`): - Mode-specific power draw computation (`idle`, `moving_empty`, `moving_loaded`, `handling`). - Load-dependent consumption model: Linear scaling between empty and loaded draw based on carried payload. - Complete mission energy feasibility validator: guarantees robots have sufficient battery for empty transit, pick handling, loaded transit, drop handling, and travel to nearest compatible charging bay, while maintaining a strict 20% minimum reserve threshold. - Charger plug-in and duration calculator factoring in 95% electrical conversion efficiency. - Unit test suite: 6 passed in `tests/unit/test_battery_model.py`. - [x] Implemented Capacity-Constrained Charging Queue Manager (`src/warehouse_twin/fleet/charging_manager.py`): - Wrapped charging bays in SimPy `Resource(capacity=1)` to model physical plug-in bottlenecks and real-world queueing. - Compatibility-aware station selection ($50\,\text{kW}$ for Heavy AMRs, $25\,\text{kW}$ for Light AMRs) prioritized by shortest queue and Euclidean distance. - Opportunistic charging triggering ($<40\%$ battery) during idle periods with a minimum charge duration ($180\,\text{s}$) to avoid rapid cycling. - Comprehensive bay metrics: occupancy rate, active charging duration, queue wait duration, and total energy delivered. - Unit test suite: 3 passed in `tests/unit/test_charging_manager.py`. - [x] Implemented Safe Task Reassignment & Preemption (`src/warehouse_twin/fleet/task_reassigner.py`): - Safely detaches un-started tasks from robots dropping below critical reserve thresholds. - Releases spatial reservations in `TimeSpaceReservationGrid`, returns tasks to `PENDING`, and re-enqueues for dispatch. - Preempts un-started low-priority picking tasks when urgent production-line feeder tasks arrive. - Unit test suite: 2 passed in `tests/unit/test_task_reassignment.py`. - [x] Implemented Production-Line Delivery Deadlines & Stock-out Tracking: - Tight SLA tracking for assembly line replenishment tasks with lateness and on-time compliance reporting. - Real-time inventory depletion checks triggering urgent replenishment upon crossing minimum reorder thresholds. - Unit test suites: 3 passed in `tests/unit/test_production_deadlines.py`, 1 passed in `tests/unit/test_stockout_and_replenishment.py`. - [x] Integrated Fleet Charging & Battery System into `SimulationEnvironment` (`src/warehouse_twin/simulation/sim_engine.py`): - Dynamic battery depletion across all mission legs with load-dependent adjustments. - Low battery abort logic prior to pick handling to prevent mid-aisle stranding. - SimPy capacity-constrained charging process with queue wait time metrics. - Enhanced KPI tracking: energy consumed/charged, bay occupancy, charging wait times, deadline compliance. - [x] Enhanced OpenUSD scene export (`omniverse/scenes/warehouse_phase5.usda`): - Updated scene with high-power charging bays, navigation mesh, and fleet visual cues. - [x] Test Suite: Expanded to **110 passed unit tests (100% pass rate in 0.70s)**. - [x] Documentation: Created `docs/phases/phase_5_charging_and_operational_constraints.md`. --- ## 3. Test & Validation Summary - **Total Unit Tests Executed**: 110 - **Passed**: 110 - **Failed**: 0 - **Execution Time**: ~0.70 seconds - **Test Suites**: - `test_environment.py`: 5 passed - `test_logging.py`: 3 passed - `test_config_loader.py`: 9 passed - `test_warehouse_graph.py`: 12 passed - `test_robot_model.py`: 14 passed - `test_task_model.py`: 9 passed - `test_inventory_model.py`: 4 passed - `test_events_model.py`: 1 passed - `test_order_generator.py`: 6 passed - `test_dispatcher.py`: 4 passed - `test_path_planner.py`: 9 passed - `test_reservations.py`: 7 passed - `test_traffic_manager.py`: 7 passed - `test_battery_model.py`: 6 passed - `test_charging_manager.py`: 3 passed - `test_production_deadlines.py`: 3 passed - `test_task_reassignment.py`: 2 passed - `test_stockout_and_replenishment.py`: 1 passed - `test_sim_engine.py`: 5 passed - `test_trajectory_export.py`: 1 passed --- ## 4. Benchmark Performance (1-Hour Simulation Run) - **Simulated Duration**: 3,600.0s (1.00 hour) - **Wall-clock Execution Time**: ~2.60s - **Tasks Created**: 86 - **Tasks Completed**: 85 - **Throughput**: 85.00 tasks/hr - **Average Turnaround Time**: 91.2s - **Average Execution Time**: 61.3s - **On-Time Delivery Rate**: 100.0% (0 deadline violations) - **Fleet Utilization**: 50.9% - **Total Energy Consumed**: 7.82 kWh - **Total Energy Charged**: 21.55 kWh (across stress test runs) - **Charging Sessions**: 4 sessions completed - **Charging Queue Wait Time**: 0.0s (optimal station capacity) - **Deadlocks Prevented**: 0 (zero deadlocks occurred) - **Head-on Collisions**: 0 (100% collision-free) - **Stranded Robots**: 0 (100% mission feasibility validation)