# Phase 5 Implementation Report: Charging and Operational Constraints **Date**: October 21, 2026 **Status**: **COMPLETED** **Phase Target**: Phase 5: Charging and Operational Constraints **Test Suite Coverage**: **110 passed in 0.68s (100% pass rate)** --- ## 1. Executive Summary Phase 5 equips the Warehouse Robot Fleet Digital Twin with **physics-informed battery dynamics, capacity-constrained charging queues, production-line delivery deadlines, inventory stock-out monitoring, and graceful task reassignment**. Key capabilities implemented in this phase: 1. **Physics-Informed Battery Model ([`battery_model.py`](file:///home/dmhai/warehouse-digital-twin/src/warehouse_twin/fleet/battery_model.py))**: - Calculates operational electrical power draw based on physical AMR mode (`idle`, `moving_empty`, `moving_loaded`, `handling`). - Implements **load-dependent power scaling**: moving loaded power scales linearly with carried payload mass: $$P(m) = P_{\text{empty}} + (P_{\text{loaded}} - P_{\text{empty}}) \times \frac{m_{\text{payload}}}{m_{\text{capacity}}}$$ - **Mission Energy Feasibility Validation**: Estimates transit and handling energy across empty transit, pickup, loaded transit, dropoff, and safety return to charging hub. Robots **cannot knowingly accept infeasible tasks** under configured battery headroom thresholds ($20\%$). 2. **Capacity-Constrained Charging Management ([`charging_manager.py`](file:///home/dmhai/warehouse-digital-twin/src/warehouse_twin/fleet/charging_manager.py))**: - SimPy `Resource`-backed charging bays with strict physical capacity limits ($\text{capacity} = 1$). - Multi-AMR charging queue arbitration tracking waiting times, session counts, and energy delivered. - Intelligent charging station selection balancing charger rating compatibility ($50\,\text{kW}$ bays for heavy AMRs, $25\,\text{kW}$ bays for light AMRs), queue backlog, and spatial transit distance. - Automated opportunity top-up charging ($\le 60\%$) when dispatch queues are clear, and mandatory return-to-base charging ($\le 25\%$). 3. **Production Line Deadlines & Lateness Tracking ([`order_generator.py`](file:///home/dmhai/warehouse-digital-twin/src/warehouse_twin/simulation/order_generator.py) & [`task.py`](file:///home/dmhai/warehouse-digital-twin/src/warehouse_twin/domain/task.py))**: - Strict SLA delivery lead times ($300\,\text{s}$) for scheduled Zone C production line feeds. - Audit tracking for on-time delivery percentages, lateness durations, and deadline miss events (`DEADLINE_MISSED`). - Dispatch queue urgency re-ordering prioritizing tasks nearest to deadline expiration. 4. **Inventory Stock-Out Monitoring**: - Real-time stock availability verification prior to task execution. - Emits `STOCKOUT_OCCURRED` telemetry events when inventory dips to zero. - Automatically enqueues high-priority inbound stock replenishment tasks. 5. **Safe Task Reassignment & Preemption ([`task_reassigner.py`](file:///home/dmhai/warehouse-digital-twin/src/warehouse_twin/fleet/task_reassigner.py))**: - Mid-transit low-battery abort: robots encountering critical battery deficit release spatial reservations, revert tasks to `PENDING`, and re-route immediately to charging stations. - Graceful preemption of unstarted low-priority tasks when urgent production-critical orders arrive. --- ## 2. Architecture & Subsystem Layout ``` src/warehouse_twin/fleet/ ├── __init__.py # Package exports ├── battery_model.py # Physics-informed power consumption & mission feasibility ├── charging_manager.py # SimPy capacity-constrained charging bays & queues └── task_reassigner.py # Graceful task abort, preemption, and queue recovery ``` ### 2.1 Battery State of Charge (SoC) Thresholds | Threshold Mode | SoC Level | Action Taken | | :--- | :--- | :--- | | **Normal Operation** | $> 60.0\%$ | Eligible for all dispatch assignments | | **Opportunistic Top-up** | $\le 60.0\%$ | Recharges at idle charging bay when dispatch queue is empty | | **Mandatory Charge** | $\le 25.0\%$ | Ineligible for new tasks; aborts unstarted transit; routes to charger | | **Safety Reserve Buffer** | $20.0\%$ | Minimum allowable projected post-mission SoC during feasibility checks | | **Critical Shutdown** | $\le 15.0\%$ | Emergency stop threshold | ### 2.2 Charging Bay Specifications | Bay ID | Position | Rated Power | Dedicated Class | Resource Capacity | | :--- | :--- | :--- | :--- | :--- | | `charge_bay_1` | $(2.0, 36.0, 0.0)$ | $25\,\text{kW}$ | Light AMR | $1$ (SimPy Resource) | | `charge_bay_2` | $(4.0, 36.0, 0.0)$ | $25\,\text{kW}$ | Light AMR | $1$ (SimPy Resource) | | `charge_bay_3` | $(6.0, 36.0, 0.0)$ | $50\,\text{kW}$ | Heavy AMR / Fast Fallback | $1$ (SimPy Resource) | | `charge_bay_4` | $(8.0, 36.0, 0.0)$ | $50\,\text{kW}$ | Heavy AMR / Fast Fallback | $1$ (SimPy Resource) | --- ## 3. Operational Benchmark Results ### 1-Hour Simulation Run (Seed 42) ```bash warehouse-twin run-sim --duration 3600 --seed 42 ``` ``` ================================================================= OPERATIONAL KPI REPORT ================================================================= Tasks Created: 86 Tasks Completed: 85 Tasks Pending: 0 Throughput: 85.00 tasks/hr Avg Turnaround Time: 91.2 s Avg Waiting Time: 29.9 s Avg Execution Time: 61.3 s On-Time Delivery Rate: 100.0% Fleet Utilization: 50.9% Replenishment Triggers: 1 ----------------------------------------------------------------- Charging & Operational Constraints (Phase 5): Missed Deadlines: 0 Stock-Out Events: 0 Reassigned Tasks: 0 Mandatory Charges: 0 Opportunity Charges: 0 Total Energy Consumed: 0.909 kWh Total Energy Charged: 0.000 kWh Fleet Battery SoC: Min 96.0%, Avg 97.1% Charging Sessions: 0 sessions (Avg queue wait: 0.0 s) ----------------------------------------------------------------- Traffic Management & Collision Avoidance (Phase 4): Conflicts Detected: 36 Yield Waits Executed: 36 Total Yield Wait Time: 56.0 s Dynamic Reroutes: 0 Deadlocks Prevented: 0 ----------------------------------------------------------------- Per-Robot Utilization & Battery Metrics: amr_light_01 : dist=1769.6m, busy=1943.4s, util=54.0%, SoC=96.0% (min 96.0%), consumed=0.121kWh amr_light_02 : dist=1365.2m, busy=1454.6s, util=40.4%, SoC=97.0% (min 97.0%), consumed=0.090kWh amr_heavy_01 : dist=1081.4m, busy=1939.9s, util=53.9%, SoC=97.8% (min 97.8%), consumed=0.330kWh amr_heavy_02 : dist=1202.4m, busy=1994.1s, util=55.4%, SoC=97.6% (min 97.6%), consumed=0.367kWh ================================================================= ``` ### Low-Battery Top-Up Stress Scenario (Initial SoC: 28%) When initial fleet SoC is initialized near the mandatory threshold ($28\%$): - **Opportunity Charging Triggered**: 4 sessions executed. - **Total Energy Charged**: $21.55\,\text{kWh}$ delivered across bays `charge_bay_3` and `charge_bay_4`. - **Ending Battery SoC**: Recharged back to $83\%\text{--}97\%$. - **Tasks Completed**: 85 tasks completed without a single deadline miss or task drop. --- ## 4. Test Suite Coverage The unit test suite has been expanded from 95 to **110 passing tests**: - [`test_battery_model.py`](file:///home/dmhai/warehouse-digital-twin/tests/unit/test_battery_model.py): 6 tests covering power draw modes, load-dependent interpolation, energy estimation, feasibility checks, and charging duration. - [`test_charging_manager.py`](file:///home/dmhai/warehouse-digital-twin/tests/unit/test_charging_manager.py): 3 tests verifying bay initialization, bay preference matching, and SimPy capacity-constrained queueing. - [`test_production_deadlines.py`](file:///home/dmhai/warehouse-digital-twin/tests/unit/test_production_deadlines.py): 3 tests verifying SLA deadline calculation, lateness tracking, and dispatcher urgency queue ordering. - [`test_task_reassignment.py`](file:///home/dmhai/warehouse-digital-twin/tests/unit/test_task_reassignment.py): 2 tests verifying low-battery task abort, reservation clearance, and priority preemption. - [`test_stockout_and_replenishment.py`](file:///home/dmhai/warehouse-digital-twin/tests/unit/test_stockout_and_replenishment.py): 1 test verifying stock-out detection and replenishment batch restocking.