8.3 KiB
8.3 KiB
Phase 5 Implementation Report: Charging and Operational Constraints
Date: October 21, 2026
Status: COMPLETED
Phase Target: Phase 5: Charging and Operational Constraints
Test Suite Coverage: 110 passed in 0.68s (100% pass rate)
1. Executive Summary
Phase 5 equips the Warehouse Robot Fleet Digital Twin with physics-informed battery dynamics, capacity-constrained charging queues, production-line delivery deadlines, inventory stock-out monitoring, and graceful task reassignment.
Key capabilities implemented in this phase:
- Physics-Informed Battery Model (
battery_model.py):- Calculates operational electrical power draw based on physical AMR mode (
idle,moving_empty,moving_loaded,handling). - Implements load-dependent power scaling: moving loaded power scales linearly with carried payload mass:
P(m) = P_{\text{empty}} + (P_{\text{loaded}} - P_{\text{empty}}) \times \frac{m_{\text{payload}}}{m_{\text{capacity}}} - Mission Energy Feasibility Validation: Estimates transit and handling energy across empty transit, pickup, loaded transit, dropoff, and safety return to charging hub. Robots cannot knowingly accept infeasible tasks under configured battery headroom thresholds (
20\%).
- Calculates operational electrical power draw based on physical AMR mode (
- Capacity-Constrained Charging Management (
charging_manager.py):- SimPy
Resource-backed charging bays with strict physical capacity limits (\text{capacity} = 1). - Multi-AMR charging queue arbitration tracking waiting times, session counts, and energy delivered.
- Intelligent charging station selection balancing charger rating compatibility (
50\,\text{kW}bays for heavy AMRs,25\,\text{kW}bays for light AMRs), queue backlog, and spatial transit distance. - Automated opportunity top-up charging (
\le 60\%) when dispatch queues are clear, and mandatory return-to-base charging (\le 25\%).
- SimPy
- Production Line Deadlines & Lateness Tracking (
order_generator.py&task.py):- Strict SLA delivery lead times (
300\,\text{s}) for scheduled Zone C production line feeds. - Audit tracking for on-time delivery percentages, lateness durations, and deadline miss events (
DEADLINE_MISSED). - Dispatch queue urgency re-ordering prioritizing tasks nearest to deadline expiration.
- Strict SLA delivery lead times (
- Inventory Stock-Out Monitoring:
- Real-time stock availability verification prior to task execution.
- Emits
STOCKOUT_OCCURREDtelemetry events when inventory dips to zero. - Automatically enqueues high-priority inbound stock replenishment tasks.
- Safe Task Reassignment & Preemption (
task_reassigner.py):- Mid-transit low-battery abort: robots encountering critical battery deficit release spatial reservations, revert tasks to
PENDING, and re-route immediately to charging stations. - Graceful preemption of unstarted low-priority tasks when urgent production-critical orders arrive.
- Mid-transit low-battery abort: robots encountering critical battery deficit release spatial reservations, revert tasks to
2. Architecture & Subsystem Layout
src/warehouse_twin/fleet/
├── __init__.py # Package exports
├── battery_model.py # Physics-informed power consumption & mission feasibility
├── charging_manager.py # SimPy capacity-constrained charging bays & queues
└── task_reassigner.py # Graceful task abort, preemption, and queue recovery
2.1 Battery State of Charge (SoC) Thresholds
| Threshold Mode | SoC Level | Action Taken |
|---|---|---|
| Normal Operation | > 60.0\% |
Eligible for all dispatch assignments |
| Opportunistic Top-up | \le 60.0\% |
Recharges at idle charging bay when dispatch queue is empty |
| Mandatory Charge | \le 25.0\% |
Ineligible for new tasks; aborts unstarted transit; routes to charger |
| Safety Reserve Buffer | 20.0\% |
Minimum allowable projected post-mission SoC during feasibility checks |
| Critical Shutdown | \le 15.0\% |
Emergency stop threshold |
2.2 Charging Bay Specifications
| Bay ID | Position | Rated Power | Dedicated Class | Resource Capacity |
|---|---|---|---|---|
charge_bay_1 |
(2.0, 36.0, 0.0) |
25\,\text{kW} |
Light AMR | 1 (SimPy Resource) |
charge_bay_2 |
(4.0, 36.0, 0.0) |
25\,\text{kW} |
Light AMR | 1 (SimPy Resource) |
charge_bay_3 |
(6.0, 36.0, 0.0) |
50\,\text{kW} |
Heavy AMR / Fast Fallback | 1 (SimPy Resource) |
charge_bay_4 |
(8.0, 36.0, 0.0) |
50\,\text{kW} |
Heavy AMR / Fast Fallback | 1 (SimPy Resource) |
3. Operational Benchmark Results
1-Hour Simulation Run (Seed 42)
warehouse-twin run-sim --duration 3600 --seed 42
=================================================================
OPERATIONAL KPI REPORT
=================================================================
Tasks Created: 86
Tasks Completed: 85
Tasks Pending: 0
Throughput: 85.00 tasks/hr
Avg Turnaround Time: 91.2 s
Avg Waiting Time: 29.9 s
Avg Execution Time: 61.3 s
On-Time Delivery Rate: 100.0%
Fleet Utilization: 50.9%
Replenishment Triggers: 1
-----------------------------------------------------------------
Charging & Operational Constraints (Phase 5):
Missed Deadlines: 0
Stock-Out Events: 0
Reassigned Tasks: 0
Mandatory Charges: 0
Opportunity Charges: 0
Total Energy Consumed: 0.909 kWh
Total Energy Charged: 0.000 kWh
Fleet Battery SoC: Min 96.0%, Avg 97.1%
Charging Sessions: 0 sessions (Avg queue wait: 0.0 s)
-----------------------------------------------------------------
Traffic Management & Collision Avoidance (Phase 4):
Conflicts Detected: 36
Yield Waits Executed: 36
Total Yield Wait Time: 56.0 s
Dynamic Reroutes: 0
Deadlocks Prevented: 0
-----------------------------------------------------------------
Per-Robot Utilization & Battery Metrics:
amr_light_01 : dist=1769.6m, busy=1943.4s, util=54.0%, SoC=96.0% (min 96.0%), consumed=0.121kWh
amr_light_02 : dist=1365.2m, busy=1454.6s, util=40.4%, SoC=97.0% (min 97.0%), consumed=0.090kWh
amr_heavy_01 : dist=1081.4m, busy=1939.9s, util=53.9%, SoC=97.8% (min 97.8%), consumed=0.330kWh
amr_heavy_02 : dist=1202.4m, busy=1994.1s, util=55.4%, SoC=97.6% (min 97.6%), consumed=0.367kWh
=================================================================
Low-Battery Top-Up Stress Scenario (Initial SoC: 28%)
When initial fleet SoC is initialized near the mandatory threshold (28\%):
- Opportunity Charging Triggered: 4 sessions executed.
- Total Energy Charged:
21.55\,\text{kWh}delivered across bayscharge_bay_3andcharge_bay_4. - Ending Battery SoC: Recharged back to
83\%\text{--}97\%. - Tasks Completed: 85 tasks completed without a single deadline miss or task drop.
4. Test Suite Coverage
The unit test suite has been expanded from 95 to 110 passing tests:
test_battery_model.py: 6 tests covering power draw modes, load-dependent interpolation, energy estimation, feasibility checks, and charging duration.test_charging_manager.py: 3 tests verifying bay initialization, bay preference matching, and SimPy capacity-constrained queueing.test_production_deadlines.py: 3 tests verifying SLA deadline calculation, lateness tracking, and dispatcher urgency queue ordering.test_task_reassignment.py: 2 tests verifying low-battery task abort, reservation clearance, and priority preemption.test_stockout_and_replenishment.py: 1 test verifying stock-out detection and replenishment batch restocking.