feat: enhance all multi-agent vision, reasoning, symbol, topology, and ingestion prompts with industrial engineering specifications

This commit is contained in:
Abhinav Gupta
2026-09-03 11:41:37 +05:30
parent 0722877947
commit f92e23accd
4 changed files with 136 additions and 96 deletions
+96 -71
View File
@@ -84,60 +84,56 @@ def _deduplicate_tiled_boxes(raw_boxes: List[Dict[str, Any]], iou_thresh: float
# ──────────────────────────────────────────────────────────────────────────────
_PID_TAG_CATEGORIES = (
" - EQUIPMENT_TAG: Compressors, motors, vessels, skids, coolers, filters "
"(e.g., 26-KA-901, TK-101, P-101).\n"
" - LINE_TAG: Piping run descriptions with size, fluid service, spec class "
"(e.g., 8\"-PV-26-9035-FC11S-08, 3\"-VA-26-9121-AC21-00).\n"
" - INSTRUMENT_TAG: Sensors, bubbles, transmitters, indicators "
"(e.g., PIT-9062, TIT-9057, PDIT-9054).\n"
" - VALVE_TAG: Manual, control, check, gate, globe, needle valves "
"(e.g., 26GB9178, HV-101, XV-201).\n"
" - PSV_TAG: Pressure Safety Valves (e.g., 26-PSV-9066A, PSV-101A).\n"
" - NOTE: Plain English notes, descriptions, labels (e.g., HIGH POINT, NOTE 35).\n"
" - RATING: Numeric specs like 150#, 2500#, pressure classes.\n"
" - EQUIPMENT_TAG: Process equipment tags with or without area prefix (e.g. 26-KA-902 compressor, "
"26-CX-9021 coalescing filter, 26-HA-911 heat exchanger, 26-TK-9001 storage tank, 26-ST-9002 suction strainer, "
"26-PA-901A pump). Capture sub-trains (e.g. HA-911-C01, HA-911-C02) and extract all dense datasheet block parameters "
"(duty, design pressure, design temperature, flow rate, material, vendor, motor rating) into attributes.\n"
" - LINE_TAG: Complete piping line designations following ISA format [Size]-[Service]-[Area]-[Sequence]-[Spec]-[Insulation] "
"(e.g. 8\"-PV-26-9035-FC11S-08, 10\"-VF-43-9027-AS20S-00, 3\"-VA-26-9121-AC21-00). Do NOT invent notes or note suffixes. "
"Reject electrical cables, transmitter loops, or motor tags from line list.\n"
" - INSTRUMENT_TAG: ISA 5.1 sensor bubbles, transmitters, switches, and relays (e.g. 26-PIT-9077, TIT-9057, "
"26-PDI-9054, 27-PY-0001BA/BB, ZIT-9011, VIT-9020). For split sibling tags ('BA/BB'), emit both individual items.\n"
" - VALVE_TAG: In-line manual and actuated valves with functional categorization (e.g. 26GB9178 Gate, 26CB9131 Check, "
"43BL9070 Ball, HV-101 Hand Control, XV-201 Shutdown, 26-ND-901 Needle, 26-BF-902 Butterfly). Extract ANSI rating class (150#, 300#, 2500#).\n"
" - PSV_TAG: Pressure Safety Relief Valves (e.g. 26-PSV-9066A, PSV-9027A, PSV-9027B). Capture set pressure (e.g. 225.4 bar(g)), "
"inlet/outlet sizes, and relief header destination (e.g. HP Flare Header, LP Flare Header).\n"
" - NOTE: Engineering callouts, revision notes, hold notes, and drawing reference markers (e.g. 'SEE DWG', 'HOLD', 'NOTE 12').\n"
" - RATING: Pressure/temperature ratings, flange classes (150#, 300#, 600#, 900#, 1500#, 2500#, PN16, PN40) and setpoint values.\n"
)
_ELECTRICAL_TAG_CATEGORIES = (
" - PANEL_TAG: Distribution boards, MDBs, LDBs, switchgear panels "
"(e.g., DB-01, MDB-A, LDB-3, EMDB, SMDB).\n"
" - LUMINAIRE_TAG: Light fittings, lamps, luminaires "
"(e.g., L-01, LS-201, TL-101, FL-01).\n"
" - CIRCUIT_TAG: Electrical circuits, breakers, MCBs "
"(e.g., C-101, CB-01, MCB-1, RCCB-3).\n"
" - ELEVATION_TAG: Elevation labels and level references "
"(e.g., EL.101.445, TL 100.000, EL +103.000).\n"
" - EQUIPMENT_TAG: Generic equipment tags (e.g., AHU-01, FAN-01, AC-01).\n"
" - NOTE: Wiring notes, area labels, installation notes.\n"
" - RATING: Electrical ratings (e.g., 415V, 32A, 3Φ).\n"
" - PANEL_TAG: Distribution boards, main switchboards, MDBs, LDBs, MCCs, control panels "
"(e.g. DB-01, MDB-A, LDB-3, EMDB, SMDB, MCC-26).\n"
" - LUMINAIRE_TAG: Light fittings, lamps, emergency exit lights, floodlights (e.g. L-01, LS-201, TL-101, FL-01, EX-01).\n"
" - CIRCUIT_TAG: Electrical branch circuits, circuit breakers, MCBs, MCCBs, fuses (e.g. C-101, CB-01, MCB-1, RCCB-3, DB-1/R1).\n"
" - ELEVATION_TAG: Elevation references and mounting heights (e.g. EL.101.445, TL 100.000, +2.400 AFF, +0.500 FFL).\n"
" - EQUIPMENT_TAG: Motors, HVAC units, transformers, generators, UPS, AHUs (e.g. M-101, TR-01, AHU-01, GEN-01).\n"
" - NOTE: Wiring specifications, installation notes, conduit sizes (e.g. 3x2.5mm² Cu/XLPE/PVC in 25mmØ conduit).\n"
" - RATING: Voltage, amperage, frequency ratings (e.g. 415V, 230V, 32A, 100A, 3Φ 50Hz, IP65, 2x36W).\n"
)
_EARTHING_TAG_CATEGORIES = (
" - EARTH_BAR_TAG: Earthing bars and main earth terminals "
"(e.g., EB-01, EBM-01, MEB).\n"
" - EARTH_PIT_TAG: Earth electrodes and earth pits "
"(e.g., EP-01, EP-A, earth pit).\n"
" - BOND_CONDUCTOR_TAG: Bonding conductors and earth cables "
"(e.g., BC-01, EC-01, earthing conductor).\n"
" - EQUIPMENT_TAG: Equipment being earthed (e.g., structural members, tanks, panels).\n"
" - ELEVATION_TAG: Elevation labels (e.g., EL.101.445, TL 100.000).\n"
" - NOTE: Installation notes, material specs (e.g., 50x6mm Copper Tape).\n"
" - RATING: Resistance values, conductor sizes (e.g., <1 Ohm, 95mm²).\n"
" - EARTH_BAR_TAG: Main earthing terminals, earth bars, clean earth bars (e.g. EB-01, EBM-01, MEB, EEB, TEB).\n"
" - EARTH_PIT_TAG: Earth test pits, earth electrodes, bore earth pits (e.g. EP-01, EP-A, TP-01, Earth Pit #4).\n"
" - BOND_CONDUCTOR_TAG: Earthing tape, bonding jumpers, grounding conductors (e.g. BC-01, EC-01, 50x6mm Cu Tape, 70mm² PVC Green/Yellow).\n"
" - EQUIPMENT_TAG: Structures, tanks, vessels, skids, motors, fence gates requiring grounding (e.g. TK-101, SK-01, Steel Column B4).\n"
" - ELEVATION_TAG: Ground elevation benchmarks and depth markings (e.g. EL.100.000, GL 0.000, -3.000m depth).\n"
" - NOTE: Resistance requirements and jointing specifications (e.g. '< 1.0 Ohm', 'Cadweld exothermic connection').\n"
" - RATING: Resistance and cross-sectional conductor ratings (e.g. 0.5 Ohm, 95mm², 120kA 1s).\n"
)
_SLD_TAG_CATEGORIES = (
" - PANEL_TAG: Switchgear, busbars, transformers, MVDBs, LVDBs "
"(e.g., MVDB-01, LVDB-A, TR-01, MSB).\n"
" - CIRCUIT_TAG: Feeders, breakers, contactors "
"(e.g., ACB-01, MCCB-3, VCB-01, feeder).\n"
" - EQUIPMENT_TAG: Motors, loads, generators (e.g., M-101, G-01).\n"
" - RATING: Electrical ratings (e.g., 11kV, 415V, 500kVA, 1250A).\n"
" - NOTE: Protection settings, fault levels, cable sizes.\n"
" - PANEL_TAG: Switchboards, busbars, MV/LV switchgear, motor control centers (e.g. MVDB-01, LVDB-A, TR-01, MSB, 11kV BUS-A).\n"
" - CIRCUIT_TAG: Air circuit breakers (ACB), vacuum circuit breakers (VCB), MCCBs, isolators, contactors (e.g. ACB-01, VCB-02, Q1, F1).\n"
" - EQUIPMENT_TAG: Heavy electrical loads, transformers, generators, variable frequency drives (VFD), motors (e.g. TR-01, M-101, VFD-01).\n"
" - RATING: Short circuit withstand, busbar current, voltage ratings (e.g. 11kV, 415V, 50kA 1s, 2500A, 500kVA, PF 0.85).\n"
" - NOTE: Protection relay settings, CT/PT ratios, interlock logic (e.g. 50/51 100/5A 5P20, Kast key interlock).\n"
)
_GENERIC_TAG_CATEGORIES = (
" - EQUIPMENT_TAG: Any equipment with a tag number (e.g., TK-101, P-101, E-201).\n"
" - NOTE: Labels, descriptions, specifications.\n"
" - RATING: Numeric specifications.\n"
" - EQUIPMENT_TAG: Any tagged industrial equipment or mechanical assembly (e.g. TK-101, P-101, E-201, C-101).\n"
" - NOTE: Descriptive engineering text, labels, instructions, material notes.\n"
" - RATING: Physical, electrical, or thermal ratings.\n"
)
_SYMBOL_VOCAB: Dict[str, str] = {
@@ -540,16 +536,29 @@ class TextRecognitionAgent(BaseAgent):
tag_categories = _get_tag_categories(drawing_type)
reasoning_prompt = (
f"You are an expert engineering data parser and reasoning engine for {drawing_type.replace('_', ' ')} drawings.\n"
"Below is the Layer 1 OCR output extracted from the drawing:\n"
f"You are a senior process and electrical engineering data parser and reasoning engine analyzing a {drawing_type.replace('_', ' ')} drawing.\n"
"Below is the Layer 1 raw OCR text elements extracted from the drawing:\n"
" <text> | conf=<confidence> | pos=(<center_x>, <center_y>)\n\n"
f"RAW OCR TEXT FROM LAYER 1:\n{raw_text_block}\n\n"
"PERFORM DEEP REASONING & REFINEMENT:\n"
"1. FIX OCR TYPOS: Correct misread letters/digits (e.g., P1T-9055 -> PIT-9055, 0B-01 -> DB-01, E8-01 -> EB-01).\n"
"2. RECOMBINE SPLIT TEXT: Re-assemble tags that were split across multiple OCR lines.\n"
"3. IDENTIFY MISPLACED DATA: Map nearby specifications (design pressure, design temp, wattage, rating, cable size, elevation, material, duty) into the parent tag's attributes dict.\n"
"4. FIND MISSING TAGS/ENTITIES: Visually inspect the drawing image to find any missing tags or equipment referenced in callouts or note blocks.\n"
"5. CLASSIFY & STRUCTURE: Map every entity into ONE of the following categories:\n"
"EXECUTE RIGOROUS ENGINEERING REASONING & REFINEMENT:\n"
"1. FIX OCR TYPOS & DECIMAL POINTS:\n"
" - Correct misread characters (e.g., P1T-9055 -> PIT-9055, 0B-01 -> DB-01, E8-01 -> EB-01, FC115 -> FC11S, B\" -> 8\").\n"
" - Restore zero-prefixed missing decimal points in pressure ratings (e.g., '005BARG' -> '0.005 BARG', '050BARG' -> '0.50 BARG').\n"
"2. RECOMBINE SPATIALLY SPLIT TEXT:\n"
" - Re-assemble multi-line piping strings (e.g., size '8\"', service 'PV', spec 'FC11S' on adjacent lines -> '8\"-PV-26-9035-FC11S-08').\n"
" - Re-assemble split valve and instrument tags (e.g., 'HV-' and '101' -> 'HV-101').\n"
"3. SPLIT SIBLING TAGS & INVERTED NOTATIONS:\n"
" - Split dual instrument transmitter tags (e.g., '27-PY-0001BA/BB' -> emit '27-PY-0001BA' and '27-PY-0001BB').\n"
" - Invert drawing-specific suction strainer tags (e.g., '9002 S 26' -> emit '26-ST-9002' as EQUIPMENT_TAG).\n"
"4. EQUIPMENT DATASHEET & ATTRIBUTE BINDING:\n"
" - Parse dense parameter blocks (Duty, Design Pressure, Design Temp, Flow Rate, Material, Vendor, Flange Rating) and inject them into the parent equipment/valve attributes dict.\n"
" - For PSVs, capture exact set pressure (e.g., '225.4 bar(g)'), inlet/outlet sizes, and relief header destination ('HP Flare Header').\n"
"5. ANTI-HALLUCINATION & STRICT SCHEMA VALIDATION:\n"
" - Do NOT invent placeholder suffixes ('...-NOTE', '...-TIT') in piping lines.\n"
" - Do NOT classify motor tags (e.g., '26-KA-902-M01') or instrument wires as lines.\n"
" - Ensure reference callouts ('FROM DWG', 'CONTINUED ON') are marked as reference notes.\n"
"6. CLASSIFY & STRUCTURE:\n"
" - Categorize every entity accurately into ONE of the following classes:\n"
+ tag_categories + "\n"
"Return the cleaned, structured findings as a validated RawTextList JSON."
)
@@ -558,8 +567,8 @@ class TextRecognitionAgent(BaseAgent):
schema=RawTextList,
prompt=reasoning_prompt,
system_instruction=(
"You are an AI engineering data reasoning engine. Your goal is to find missing data, "
"correct OCR errors, map misplaced attributes, and output clean structured JSON."
"You are an expert AI engineering data reasoning engine. Your objective is to achieve 100% extraction fidelity: "
"correct all OCR errors, restore dropped decimals, bind datasheet attributes, reject hallucinations, and output clean structured JSON."
),
image_path=raw_image,
provider=llm_provider,
@@ -751,14 +760,24 @@ class SymbolRecognitionAgent(BaseAgent):
elif not (local_mode or symbol_engine == "local"):
prompt = (
f"You are an expert industrial vision detector specializing in ISA-5.1 and engineering symbol recognition for {dt_label} drawings.\n"
f"Identify all graphical component symbols present in this drawing image.\n\n"
f"SYMBOL TAXONOMY VOCABULARY:\n {symbol_vocab}\n\n"
"FOR EACH DETECTED SYMBOL PROVIDE:\n"
" 1. symbol_type: The exact symbol classification from the taxonomy vocabulary.\n"
" 2. inferred_tag: Nearest readable tag number/ID (e.g., 26CB9131, PIT-9055, DB-01, EP-01) if visible nearby.\n"
" 3. ymin, xmin, ymax, xmax: Normalized bounding box coordinates between 0.0 and 1.0.\n\n"
"Return the list of detected symbols in structured JSON format."
f"You are a computer vision specialist in ISA-5.1 industrial symbol taxonomy and electrical schematics for {dt_label} drawings.\n\n"
"OBJECTIVE: Detect and localize all graphical components and symbols on the drawing canvas.\n\n"
f"AUTHORIZED SYMBOL VOCABULARY:\n {symbol_vocab}\n\n"
"MORPHOLOGICAL SYMBOL RECOGNITION RULES:\n"
" • CHECK_VALVE: Two opposing triangles or a directional flap/arrowhead across a seat.\n"
" • GATE_VALVE: Two opposing triangles touching at vertex along a pipeline.\n"
" • BALL_VALVE: Opposing triangles with a solid black/filled circle at center.\n"
" • GLOBE_VALVE: Opposing triangles with an open circle at center.\n"
" • CONTROL_VALVE: Valve body attached to a top pneumatic diaphragm/dome or motor actuator.\n"
" • PSV / SAFETY_VALVE: Angled body with inlet on run and discharge elbow to header with spring bonnet.\n"
" • INST_BUBBLE: Circular bubbles (field mounted = plain circle, control room = horizontal line across circle).\n"
" • STRAINER: Y-shaped branch casing or in-line bucket strainer body (e.g. 26-ST-9002).\n"
" • EQUIPMENT: Major vessels, compressors (trapezoidal profile), pumps (circular impeller casing), heat exchangers.\n\n"
"FOR EACH DETECTED SYMBOL:\n"
" 1. symbol_type: Must match one authorized classification from the vocabulary.\n"
" 2. inferred_tag: Associated adjacent tag label (e.g. 26CB9131, 26-KA-902, 26-ST-9002) if legible.\n"
" 3. ymin, xmin, ymax, xmax: Normalized bounding box [0.0 to 1.0] tightly enclosing the symbol icon.\n\n"
"Return the full symbol inventory in structured JSON format conforming to RawSymbolList."
)
try:
@@ -931,17 +950,23 @@ class PipelineRecognitionAgent(BaseAgent):
# Option B: Full Multimodal VLM Polyline Tracer or Hybrid CV + VLM
elif not (local_mode or pipeline_engine == "proximity_tracer"):
prompt = (
f"You are an expert topological pipeline and electrical connectivity tracer analyzing a {dt_label} drawing.\n\n"
"TASK 1 — TOPOLOGICAL RELATIONSHIPS:\n"
"Extract source→target connectivity pairs:\n"
" - MONITORS: Instrument or sensor monitoring a line or equipment.\n"
" - INSTALLED_ON: Valve or fitting installed on a line run.\n"
" - CONNECTS_TO: Pipe, busbar, or cable connecting two pieces of equipment.\n"
" - FEEDS: Distribution panel or switchboard feeding a circuit or breaker.\n"
" - EARTHED_TO: Equipment grounded to an earth bar or earth pit.\n\n"
"TASK 2 — GEOMETRY & SHEET GRIDS:\n"
"List the border grid sector designations (e.g., A1, B5, C9, D10) and trace any named piping runs or cable routes.\n\n"
"Return all findings in structured JSON format."
f"You are a principal process piping and electrical systems engineer analyzing topological connectivity on a {dt_label} drawing.\n\n"
"TASK 1 — TOPOLOGICAL CONNECTIVITY & STREAM GRAPH GENERATION:\n"
"Extract exact [source_tag] -> [target_tag] relationships adhering to physical flow directionality:\n"
" - INSTALLED_ON: In-line valves, check valves, control valves, strainers, or PSVs installed along a specific piping line.\n"
" (Example: '26CB9131' INSTALLED_ON '8\"-PV-26-9035-FC11S-08', 'PSV-9027A' INSTALLED_ON '10\"-VF-43-9027-AS20S-00').\n"
" *CRITICAL*: PSVs are installed on host process piping lines, NEVER arbitrarily mapped to distant vessels or coalescers.\n"
" - RELIEVES_TO: PSV discharge routing to flare or atmospheric relief headers (e.g. 'PSV-9027A' RELIEVES_TO 'HP Flare Header').\n"
" - DRAINS_TO: Equipment drains and low-point purges routing to drain headers (e.g. '26-HA-911' DRAINS_TO 'CLOSED DRAIN').\n"
" - MONITORS: Instrument sensors tapping into process lines or equipment nozzles (e.g. '26-PIT-9077' MONITORS '8\"-PV-26-9035-FC11S-08').\n"
" - CONNECTS_TO: Continuous process piping connecting source equipment nozzles to destination equipment nozzles.\n"
" - FEEDS: Power distribution switchgear, MDBs, or panels feeding electrical branch circuits or loads.\n"
" - EARTHED_TO: Equipment or structures connected via bonding tape to earth bars or earth pits.\n\n"
"DIRECTIONALITY CONSTRAINTS:\n"
" - FLARE, HP FLARE, LP FLARE, CLOSED DRAIN, OPEN DRAIN, ATMOSPHERE, VENT, and SUMP are TERMINAL SINKS (must always be targets, never sources feeding process units).\n\n"
"TASK 2 — GEOMETRY & SHEET BORDER GRIDS:\n"
"Identify border grid sector designations (e.g., A1, B5, C9, D10) and trace continuous polyline coordinates for all major process streams.\n\n"
"Return all findings as validated JSON conforming to the RawPipelineList schema."
)
try: