- Un-gated pattern loops across all drawing types in tag_classifier.py - Added missing EARTH_PIT_TAG & BOND_CONDUCTOR_TAG passes and expanded IEEE 80 / IS 3043 earthing patterns - Expanded Luminaire, Distribution Panel, and Circuit search patterns - Added smart compiler defaults for materials, dimensions, and resistance limits in compiler.py - Un-gated EARTHED_TO and FEEDS topological relations mapping across all drawings in line_tracer.py - Fixed EquipmentItem missing location attribute error in models.py and output_generator.py - Fixed Relationship missing source_tag attribute error by adding property getters in models.py - Updated SmartPlant CSV and Excel generators to export RELATIONSHIP rows and dynamic Earthing/Equipment sheets - Updated README.md and .gitignore
121 lines
4.8 KiB
Python
121 lines
4.8 KiB
Python
"""Unit test for Earthing & Lighting / Electrical layout component extraction."""
|
|
from src.utils.tag_classifier import classify_paddle_results
|
|
from src.agents.compiler import CompilerAgent
|
|
from src.utils.line_tracer import trace_lines_and_connections
|
|
|
|
# Earthing test inputs
|
|
earthing_ocr = [
|
|
{'text': 'EBM-01', 'confidence': 0.95},
|
|
{'text': 'EB-101', 'confidence': 0.95},
|
|
{'text': 'MAIN EARTH BAR', 'confidence': 0.95},
|
|
{'text': 'EP-01', 'confidence': 0.95},
|
|
{'text': 'EARTH PIT', 'confidence': 0.95},
|
|
{'text': 'EARTH CHAMBER', 'confidence': 0.95},
|
|
{'text': 'BC-01', 'confidence': 0.95},
|
|
{'text': 'COPPER TAPE', 'confidence': 0.95},
|
|
{'text': 'GS FLAT 50X6 MM', 'confidence': 0.95},
|
|
{'text': '70 SQMM', 'confidence': 0.95},
|
|
]
|
|
|
|
# Lighting / Electrical test inputs
|
|
lighting_ocr = [
|
|
{'text': 'L-01', 'confidence': 0.95},
|
|
{'text': 'TL-101', 'confidence': 0.95},
|
|
{'text': 'FL-01', 'confidence': 0.95},
|
|
{'text': 'FLOODLIGHT-01', 'confidence': 0.95},
|
|
{'text': 'WELLGLASS', 'confidence': 0.95},
|
|
{'text': 'EMERGENCY LIGHT', 'confidence': 0.95},
|
|
{'text': 'LIGHTING PANEL LP-01', 'confidence': 0.95},
|
|
{'text': 'DB-01', 'confidence': 0.95},
|
|
{'text': 'MDB-A', 'confidence': 0.95},
|
|
]
|
|
|
|
print("=== 1. CLASSIFIER EARTHING TEST ===")
|
|
e_results = classify_paddle_results(earthing_ocr, drawing_type="EARTHING_LAYOUT")
|
|
by_tag_e = {r['tag'].upper(): r for r in e_results}
|
|
|
|
earthing_expected = [
|
|
('EBM-01', 'EARTH_BAR_TAG'),
|
|
('EB-101', 'EARTH_BAR_TAG'),
|
|
('MAIN EARTH BAR', 'EARTH_BAR_TAG'),
|
|
('EP-01', 'EARTH_PIT_TAG'),
|
|
('EARTH PIT', 'EARTH_PIT_TAG'),
|
|
('EARTH CHAMBER', 'EARTH_PIT_TAG'),
|
|
('BC-01', 'BOND_CONDUCTOR_TAG'),
|
|
('COPPER TAPE', 'BOND_CONDUCTOR_TAG'),
|
|
('GS FLAT', 'BOND_CONDUCTOR_TAG'),
|
|
('70 SQMM', 'BOND_CONDUCTOR_TAG'),
|
|
]
|
|
|
|
e_pass = 0
|
|
for tag, exp_cls in earthing_expected:
|
|
r = by_tag_e.get(tag.upper())
|
|
got_cls = r['classification'] if r else 'NOT_FOUND'
|
|
ok = got_cls == exp_cls
|
|
if ok: e_pass += 1
|
|
status = 'OK ' if ok else 'FAIL'
|
|
print(f' [{status}] {tag:20s} -> {got_cls:20s} (expected {exp_cls})')
|
|
|
|
print(f'\nEarthing Classifier Results: {e_pass}/{len(earthing_expected)} passed')
|
|
|
|
print("\n=== 2. CLASSIFIER LIGHTING & ELECTRICAL TEST ===")
|
|
l_results = classify_paddle_results(lighting_ocr, drawing_type="ELECTRICAL_LAYOUT")
|
|
by_tag_l = {r['tag'].upper(): r for r in l_results}
|
|
|
|
lighting_expected = [
|
|
('L-01', 'LUMINAIRE_TAG'),
|
|
('TL-101', 'LUMINAIRE_TAG'),
|
|
('FL-01', 'LUMINAIRE_TAG'),
|
|
('FLOODLIGHT-01', 'LUMINAIRE_TAG'),
|
|
('WELLGLASS', 'LUMINAIRE_TAG'),
|
|
('EMERGENCY LIGHT', 'LUMINAIRE_TAG'),
|
|
('LIGHTING PANEL LP', 'PANEL_TAG'),
|
|
('DB-01', 'PANEL_TAG'),
|
|
('MDB-A', 'PANEL_TAG'),
|
|
]
|
|
|
|
l_pass = 0
|
|
for tag, exp_cls in lighting_expected:
|
|
r = by_tag_l.get(tag.upper())
|
|
got_cls = r['classification'] if r else 'NOT_FOUND'
|
|
ok = got_cls == exp_cls
|
|
if ok: l_pass += 1
|
|
status = 'OK ' if ok else 'FAIL'
|
|
print(f' [{status}] {tag:25s} -> {got_cls:20s} (expected {exp_cls})')
|
|
|
|
print(f'\nLighting/Electrical Classifier Results: {l_pass}/{len(lighting_expected)} passed')
|
|
|
|
print("\n=== 3. COMPILER AGENT EARTHING & LIGHTING TEST ===")
|
|
ca = CompilerAgent()
|
|
|
|
# Compile earthing items
|
|
compiled_earth = ca._compile_earthing(e_results, [])
|
|
print(f' Compiled {len(compiled_earth)} EarthingItem objects:')
|
|
for e in compiled_earth:
|
|
print(f' Tag: {e.tag:20s} | Type: {e.component_type:15s} | Material: {e.material} | Size: {e.size}')
|
|
|
|
# Compile luminaire items
|
|
compiled_lum = ca._compile_luminaires(l_results, [])
|
|
print(f'\n Compiled {len(compiled_lum)} LuminaireItem objects:')
|
|
for lum in compiled_lum:
|
|
print(f' Tag: {lum.tag:25s} | Type: {lum.fitting_type:20s} | Wattage: {lum.wattage}')
|
|
|
|
# Compile panel items
|
|
compiled_pan = ca._compile_panels(l_results, [])
|
|
print(f'\n Compiled {len(compiled_pan)} PanelItem objects:')
|
|
for pan in compiled_pan:
|
|
print(f' Tag: {pan.tag:25s} | Type: {pan.panel_type:20s} | Voltage: {pan.voltage}')
|
|
|
|
print("\n=== 4. LINE TRACER TOPOLOGICAL RELATIONS TEST ===")
|
|
all_entities = e_results + l_results + [{'classification': 'EQUIPMENT_TAG', 'tag': 'P-101', 'attributes': {}}]
|
|
tracer_res = trace_lines_and_connections(None, all_entities, [], drawing_type="EARTHING_LAYOUT")
|
|
|
|
relations = tracer_res['relations']
|
|
print(f' Generated {len(relations)} topological relations:')
|
|
for rel in relations:
|
|
print(f' {rel["source_tag"]:25s} --[{rel["rel_type"]}]--> {rel["target_tag"]}')
|
|
|
|
total_tests = len(earthing_expected) + len(lighting_expected)
|
|
total_passed = e_pass + l_pass
|
|
print(f'\n=== FINAL SCORE: {total_passed}/{total_tests} tests passed ===')
|