Abhinav Gupta c28be21557 feat(precision): achieve 100% ground truth recall and 76.47% entity precision
- Add centralized ISA 5.1/ISO 15926 taxonomy and DecomposedTag model
- Implement multi-evidence candidate scoring and explainable merge provenance
- Refine CompilerAgent: ISA loop consolidation, dense valve formatting, cross-system isolation
- Enforce canonical endpoint strictness for relationships (zero raw OCR strings)
- Update ValidationAgent with structured actionable feedback
- Add comprehensive test suites (60 pytest + 43 hybrid tests passing 100%)
- Generate baseline, regression, validation, confusion matrix, and final audit reports
2026-09-30 12:00:27 +05:30

125 lines
7.6 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Precision Baseline Evaluation Report
**Document Version:** 1.0.0
**Target Branch:** `precision`
**Date:** 2026-09-30
**Representative Ground Truth P&ID:** `pid_stuff/Lift Gas compressor-PID.pdf` (Drawing `26-KA-901`)
**Ground Truth Reference:** `pid_stuff/PID_Extraction_RevB_Corrected_26-KA-901_902 (2).xlsx`
**Status:** Frozen Baseline — Do NOT Modify After Implementation
---
## 1. Executive Summary
This document establishes the official empirical baseline for the MTO2Doc precision engineering branch.
Measurements were conducted on the primary representative drawing `Lift Gas compressor-PID.pdf` (`26-KA-901`) against the engineer-verified ground truth extraction sheet (`PID_Extraction_RevB_Corrected_26-KA-901_902 (2).xlsx`).
The empirical evidence confirms the central thesis of the project:
* **Perception Recall is exceptionally high (96.15% Overall Entity Recall):** 100 out of 104 ground truth entities were successfully captured by the visual and text perception layers.
* **Canonical Entity Precision is low (48.87% Overall Precision):** The pipeline generated 221 compiled canonical entities for 104 real objects—a **51.13% duplicate and false entity rate**.
* **Relationship Topology is contaminated:** 230 compiled relationships contain edges connecting valves to raw OCR specification strings (e.g. `SP-26-300-26GT9174-1`) or instrument bubbles (e.g. `PI-9062-PIT-9062`) rather than canonical process lines.
---
## 2. Core Quantitative Baseline Metrics
The quantitative metrics below are stored in machine-readable JSON format at [`PRECISION_BASELINE.json`](file:///c:/DS_and_AI/Projects_and_Tutorials/Projects/pid_project/PRECISION_BASELINE.json):
| Metric | Measured Baseline Value | Target Requirement | Gap to Target |
|---|---|---|---|
| **Raw Observation Count** | **2,024** | — | Visual & OCR observation pool |
| **Candidate Count** | **1,450** | — | Intermediate classified items |
| **Ground Truth Entities ($GT$)** | **104** | — | Real canonical engineering objects |
| **Compiled Entities ($Comp$)** | **221** | 104–110 | +117 surplus entities (+112.5% inflation) |
| **True Positives ($TP$)** | **100** | $\ge 100$ | Baseline recall foundation |
| **False Positives ($FP$)** | **113** | $\le 10$ | Primary target for precision repair |
| **False Negatives ($FN$)** | **4** | $\le 4$ | Preservation gate |
| **Overall Entity Recall** | **96.15%** | $\ge 96.15\%$ (No regression) | **PASS (Baseline Gate)** |
| **Overall Entity Precision** | **48.87%** | $\ge 90.0\%$ | **-41.13% (Target for Phase 9–16)** |
| **Overall F1 Score** | **0.6480** | $\ge 0.930$ | +0.282 required |
| **Duplicate Entity Rate** | **51.13%** | $< 5.0\%$ | -46.13% reduction required |
| **False Entity Rate** | **51.13%** | $< 5.0\%$ | -46.13% reduction required |
| **Classification Error Rate** | **37.10%** | $< 5.0\%$ | Control valve & suffix absorption |
| **Compiled Relationships** | **230** | — | Clean canonical edges only |
| **Relationship Precision** | **~32.5%** | $\ge 90.0\%$ | Exclude raw OCR endpoints |
| **Relationship Recall** | **NOT YET MEASURABLE** | $\ge 90.0\%$ | Full drawing edge graph not fully tabulated |
| **Re-Extraction Count** | **0** | Pass-specific | Idempotence required |
---
## 3. Discipline & Category Performance Breakdown
| Engineering Category | Ground Truth ($GT$) | Compiled Entities | True Positives ($TP$) | False Positives ($FP$) | False Negatives ($FN$) | Category Recall | Category Precision | Category F1 |
|---|---|---|---|---|---|---|---|---|
| **EQUIPMENT** | 7 | 20 | 6 | 10 | 1 | **85.71%** | **50.00%** | **0.6316** |
| **SAFETY RELIEF (PSV)** | 2 | 2 | 2 | 0 | 0 | **100.00%** | **100.00%** | **1.0000** |
| **INSTRUMENTS** | 20 | 61 | 17 | 40 | 3 | **85.00%** | **34.43%** | **0.4900** |
| **VALVES** | 40 | 72 | 40 | 32 | 0 | **100.00%** | **55.56%** | **0.7143** |
| **LINES** | 35 | 66 | 35 | 31 | 0 | **100.00%** | **53.03%** | **0.6931** |
| **TOTAL** | **104** | **221** | **100** | **113** | **4** | **96.15%** | **48.87%** | **0.6480** |
---
## 4. Analysis of Ground Truth vs Extraction Deficits
### 4.1 Equipment (Recall: 85.71%, Precision: 50.00%)
* **Ground Truth (7 items):**
1. `26-KA-901` (3rd Stage HP Gas Lift Compressor) — **CAPTURED**
2. `26-KA-901-M01` (Compressor Motor) — **CAPTURED**
3. `26-KZ-901` (Compressor Skid Package) — **CAPTURED**
4. `26-HA-911` (Seal Gas Cooler) — **CAPTURED**
5. `26-CX-9011` (OMS Module) — **CAPTURED**
6. `26-CX-9122` (Seal Gas Booster) — **CAPTURED**
7. `26-CK-911` (Suction Strainer) — **MISSED (FN)** (labeled `CK-911` in drawing notes, classified as valve due to `CK` code).
* **False Positives (10 items):**
- Text descriptions and drawing callouts (e.g. `3RD STAGE HP GAS LIFT COMPRESSOR`, `COMPRESSOR SKID`, `MAN ENERGY SOLUTIONS`) parsed by regex allowlist as generic equipment.
- Sub-assembly callouts (`HA-911-C01`, `HA-911-C02`) created redundant equipment items instead of sub-assemblies.
### 4.2 Safety Relief Valves (Recall: 100.0%, Precision: 100.0%)
* **Ground Truth (2 items):**
1. `26-PSV-9066A` (Compressor Discharge Relief Duty) — **CAPTURED**
2. `26-PSV-9066B` (Compressor Discharge Relief Standby) — **CAPTURED**
* **Performance:** Flawless precision and recall. Both PSVs correctly captured with set pressure parsing.
### 4.3 Instruments (Recall: 85.00%, Precision: 34.43%)
* **Ground Truth (20 items):**
- 17 items captured: `26-PIT-9055`, `26-PDIT-9054`, `26-PIT-9058`, `26-TIT-9057`, `26-TIT-9211`, `26-PIT-9215`, `26-FE-9056`, `26-PDIT-9056`, `26-PIT-9062`, `26-PIT-9065`, `26-TIT-9063`, `26-TIT-9064`, `26-PDIT-9757`, `26-FE-9757`, `26-PIT-9759`, `26-PY-9077A`, `26-PY-9077B`.
- 3 items missed:
1. `26-PSE-9216` (Rupture disc: regex did not recognize `PSE` as an instrument).
2. `26-PSE-9758` (Rupture disc: same issue).
3. `40-XV-9010` (Cooling water on/off valve: classified as valve `XV` rather than instrument list).
* **False Positives (40 surplus instruments):**
- Duplicate loop observations: `PDIT-9054` and `26-PDIT-9054` and `PDIT-9054-HH` compiled as 3 instruments.
- Alarm suffix tokens (`HH`, `LL`, `SD`) captured as bare instrument tags.
- Control functions (`FV`, `PV`) creating duplicate instruments alongside valves.
### 4.4 Manual Valves (Recall: 100.0%, Precision: 55.56%)
* **Ground Truth (40 items):**
- All 40 ground truth valves (`26BL9072` to `40GT9308`) were detected ($Recall = 100\%$).
* **False Positives (32 surplus valves):**
- Duplicate bare vs prefixed tags (`26BL9072` vs `BL9072`).
- Untagged symbol harvester synthesized `GV-SYM-01`, `CB-SYM-02` for graphic features that were already tagged or were pipe crossovers.
### 4.5 Piping Lines (Recall: 100.0%, Precision: 53.03%)
* **Ground Truth (35 lines):**
- All 35 ground truth lines (`8"-PV-26-9035-FC11S-08` through `4"-WC-26-9128-EC11S-00`) were detected ($Recall = 100\%$).
* **False Positives (31 surplus lines):**
- Multiple text fragments of the same continuous pipeline along different sheet regions compiled as separate lines.
- Line spec strings and insulation suffixes parsed as standalone lines.
---
## 5. Non-Negotiable Regression Floor
The following baseline metrics form the **absolute regression gates** for all subsequent phases:
$$\text{OVERALL ENTITY RECALL} \ge 96.15\%$$
$$\text{LINE RECALL} \ge 100.00\%$$
$$\text{VALVE RECALL} \ge 100.00\%$$
$$\text{PSV RECALL} \ge 100.00\%$$
$$\text{EQUIPMENT RECALL} \ge 85.71\%$$
$$\text{INSTRUMENT RECALL} \ge 85.00\%$$
No architectural change that causes recall to drop below these thresholds will be accepted.
The precision improvement must be achieved through **evidence fusion, candidate normalization, canonical deduplication, and topology gating**, NEVER by threshold deletion or detection suppression.