Files
PID2DOC/PRECISION_SURGICAL_CHANGELOG.md
T

170 lines
11 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# PRECISION SURGICAL CHANGELOG
**Branch:** `precision`
**System:** MTO2Doc / SID-AI Universal Engineering Graph
**Scope:** Surgical precision stabilization, reference isolation, generic component deduplication, and topology repair across dual P&IDs (26-KA-901 and 26-KA-902).
---
## 1. Change Register
### CHG-01: Reference Model Extension
* **File:** `src/models.py`
* **Function/Class:** `ReferenceItem`, `UniversalEngineeringGraph`, `Relationship`
* **Problem:** No structured model existed in the universal graph for external / off-sheet continuation references (`FROM ...`, `TO ...`).
* **Root Cause:** Graph models only contained physical entities, forcing references into instruments or generic components.
* **Change:** Added `ReferenceItem` with fields `reference_id`, `referenced_tag`, `reference_type`, `source_text`, `context`, `direction`, `source_region`, `coordinates`, `confidence`, `target_entity_id`, and `external`. Added `references: List[ReferenceItem]` to `UniversalEngineeringGraph`. Added `domain: str` and `evidence_vector: Optional[Dict[str, float]]` to `Relationship`.
* **Expected Effect:** Enables clean separation of off-sheet references from physical entities.
* **Tests:** `tests/test_precision_models.py`, `scratch_evaluate_both.py`
* **Regression Status:** Verified PASSED (0 regressions across both drawings).
---
### CHG-02: Drawing Reference Number vs. Suffix Guard
* **File:** `src/utils/tag_classifier.py`
* **Function/Class:** `classify_paddle_results` (`_PROJECT_TAG_SEARCH` loop)
* **Problem:** `27-PY-0001BA` and `27-PY-0001BB` on Drawing B were misclassified as `NOTE` instead of `INSTRUMENT_TAG`.
* **Root Cause:** `if len(seq) == 6: continue` treated any 6-character sequence as a drawing reference number. The 6-character sequence `0001BA` was dropped.
* **Change:** Guard drawing number check to `if seq.isdigit() and len(seq) == 6: continue`.
* **Expected Effect:** Recovers `27-PY-0001BA` and `27-PY-0001BB` instruments with 100% precision.
* **Tests:** `scratch_evaluate_both.py`
* **Regression Status:** Verified PASSED.
---
### CHG-03: Multi-Line Bubble Stacking Guard Against Drawing References & Number Run-Ons
* **File:** `src/utils/tag_stitcher.py`
* **Function/Class:** `stitch_symbol_bubbles`
* **Problem:** Drawing title notes concatenated into `STAGE-26-000001-001-26-PIT-9087`, and adjacent bubble numbers concatenated into `TI-9023`.
* **Root Cause:** `stitch_symbol_bubbles` vertically stacked notes and drawing numbers if aligned in X, and lacked guards for multi-number sequence run-ons (`90239025`).
* **Change:** Exclude tokens with drawing numbers (`\d{5,}`), multi-numbers (`\d{3,}\s+\d{3,}`), or general stage note words from bubble stitching.
* **Expected Effect:** Eliminates malformed composite tag creation and fake bubble tags (`TI-9023`, `STAGE-26-000001-001`).
* **Tests:** `scratch_evaluate_both.py`
* **Regression Status:** Verified PASSED.
---
### CHG-04: Generic Equipment Allowlist Full-Word Prefix Matching
* **File:** `src/utils/tag_classifier.py`
* **Function/Class:** `classify_paddle_results` (`_GENERIC_EQUIP_PATTERN` loop)
* **Problem:** Any string starting with `STA` (e.g. `STAGE`) matched `_EQUIP_PREFIX_ALLOWLIST`.
* **Root Cause:** Regex `r'^([A-Z]{1,3})'` extracted only first 3 letters instead of full word before hyphen.
* **Change:** Extract full prefix before hyphen (`code_m = re.match(r'^([A-Z]+)-', full_tag)`) and check against allowlist.
* **Expected Effect:** Eliminates words like `STAGE` from becoming equipment.
* **Tests:** `scratch_evaluate_both.py`
* **Regression Status:** Verified PASSED.
---
### CHG-05: Generalized Suction Strainer Equipment Resolution
* **File:** `src/agents/compiler.py` & `src/utils/tag_classifier.py`
* **Function/Class:** `_compile_equipment`
* **Problem:** `26-CK-921` on Drawing B was classified as valve instead of equipment suction strainer.
* **Root Cause:** Code contained hardcoded `CK-911` check instead of generalized `CK-\d{3}` suction strainer check.
* **Change:** Generalize rule so any `CK` tag with 3-digit sequence (`(?:26-)?CK-\d{3}`) is recognized as suction strainer equipment across both drawings.
* **Expected Effect:** Recovers `26-CK-921` on Drawing B without impacting Drawing A.
* **Tests:** `scratch_evaluate_both.py`
* **Regression Status:** Verified PASSED (Drawing A: 100% Rec/Prec, Drawing B: 100% Rec/Prec).
---
### CHG-06: Elimination of Generic Component Duplication
* **File:** `src/agents/compiler.py`
* **Function/Class:** `_compile_generic`
* **Problem:** 12–14 generic components duplicated existing canonical equipment (`26-KA-902`, `26-CX-9222`, etc.).
* **Root Cause:** `_compile_generic` filtered for `('EQUIPMENT_TAG', 'GENERIC_TAG')`, re-adding all equipment.
* **Change:** Restrict `_compile_generic` to `GENERIC_TAG` only. Before emission, resolve candidate against `tag_alias_map` and base tags.
* **Expected Effect:** Reduces generic component duplicate count to 0 for known entities.
* **Tests:** `scratch_evaluate_both.py`
* **Regression Status:** Verified PASSED (Generic components dropped from 14/12 to **0** on both drawings).
---
### CHG-07: Reference vs. Physical Entity Routing
* **File:** `src/agents/compiler.py` & `src/utils/tag_classifier.py`
* **Function/Class:** `_compile_equipment`, `_compile_instruments`, `_compile_references`
* **Problem:** External references (`FROM 27-PIT-0001B`, `FROM 26-PIT-9087`, `FROM 26-PIT-9077`) became physical entities.
* **Root Cause:** `_compile_instruments` and `_compile_equipment` did not route off-sheet references to `ReferenceItem`.
* **Change:** Pre-scan explicit `FROM <TAG>` and `TO <TAG>` callouts. Compile them into `graph.references`. Compile `graph.references` first and exclude reference keys from local physical equipment and instruments.
* **Expected Effect:** Prevents off-sheet references from inflating physical instrument/equipment counts while preserving traceability.
* **Tests:** `scratch_evaluate_both.py`
* **Regression Status:** Verified PASSED (27-PIT-0001B and 26-PIT-9087 cleanly compiled as references, Drawing B Instrument Precision reaches 100%).
---
### CHG-08: Base Tag / Suffix Resolution & Loop Consolidation
* **File:** `src/agents/compiler.py`
* **Function/Class:** `_compile_equipment`, `_compile_instruments`
* **Problem:** Variant tags (`26-KA-902-STAGE`, `26-CX-9222-2500`, `26-FI-9017`) duplicated base objects.
* **Root Cause:** Suffix stripping occurred after reference checks, and flow loop key formulation was hardcoded to 9056/9757.
* **Change:** Derive `BASE_TAG`, clean suffixes before reference filtering, and generalize ISA flow measurement loop key to `f"{area}_LOOP_F_{seq}"` so primary transmitters absorb secondary indicators across all drawings.
* **Expected Effect:** Merges suffix variations into single canonical entities and consolidates loop 9017 on Drawing B.
* **Tests:** `scratch_evaluate_both.py`
* **Regression Status:** Verified PASSED.
---
### CHG-09: Surgical Topology Repair & Fallback Elimination
* **File:** `src/utils/line_tracer.py` & `src/agents/compiler.py`
* **Function/Class:** `_trace_instrument_connectivity`, `_compile_relationships`
* **Problem:** 23 artificial `MONITORS` relationships per drawing generated by proximity fallback without evidence.
* **Root Cause:** Fallback #4, #5, #6 in line_tracer and lines 196–228 in compiler forcibly connected every unattached instrument to the nearest line with `confidence = 0.85` or `1.0`.
* **Change:** Removed artificial fallbacks. Compute geometric distance with `_find_closest_line_segment_with_dist`. Calculate dynamic evidence vectors (`geometry`, `topology`, `semantic`). Assign explicit domain (`PHYSICAL`, `CONTROL`, `REFERENCE`, `ELECTRICAL`) and semantic types (`MEASURES`, `SIGNALS_TO`, `INSTALLED_ON`, `CONTROLS`).
* **Expected Effect:** Eliminates spurious `MONITORS` edges, leaving only verified physical and control connections.
* **Tests:** `verify_pipeline.py`, `scratch_evaluate_both.py`
* **Regression Status:** Verified PASSED.
---
## 2. Before / After Regression Evaluation Table
### Drawing A: 26-KA-901 (Lift Gas Compressor P&ID)
| Metric | Baseline Before | Surgical After | Delta |
| :--- | :---: | :---: | :---: |
| **Core Entity Recall** | 100.00% (104/104) | **100.00% (104/104)** | **0.00% (Preserved)** |
| **Core Entity Precision** | 76.47% (104/136) | **76.47% (104/136)** | **Stable** |
| **Equipment Recall** | 100.00% (7/7) | **100.00% (7/7)** | **0.00% (Preserved)** |
| **Equipment Precision** | 100.00% (7/7) | **100.00% (7/7)** | **0.00% (Preserved)** |
| **PSV Recall** | 100.00% (2/2) | **100.00% (2/2)** | **0.00% (Preserved)** |
| **PSV Precision** | 100.00% (2/2) | **100.00% (2/2)** | **0.00% (Preserved)** |
| **Instrument Recall** | 100.00% (20/20) | **100.00% (20/20)** | **0.00% (Preserved)** |
| **Instrument Precision** | 90.91% (20/22) | **90.91% (20/22)** | **0.00% (Preserved)** |
| **Valve Recall** | 100.00% (40/40) | **100.00% (40/40)** | **0.00% (Preserved)** |
| **Valve Precision** | 61.54% (40/65) | **61.54% (40/65)** | **0.00% (Preserved)** |
| **Line Recall** | 100.00% (35/35) | **100.00% (35/35)** | **0.00% (Preserved)** |
| **Line Precision** | 87.50% (35/40) | **87.50% (35/40)** | **0.00% (Preserved)** |
| **Generic Components** | 14 duplicates | **0** | **-100% (Eliminated)** |
| **Spurious Fallback Edges** | 23 (`MONITORS`) | **0** | **-100% (Eliminated)** |
| **Total Relationships** | 86 (untyped) | **64 (domain-typed)** | **Auditable Evidence** |
---
### Drawing B: 26-KA-902 (Export Gas Compressor P&ID)
| Metric | Baseline Before | Surgical After | Delta |
| :--- | :---: | :---: | :---: |
| **Core Entity Recall** | 98.86% (87/88) | **98.86% (87/88)** | **0.00% (Preserved)** |
| **Core Entity Precision** | 77.68% (87/112) | **81.48% (87/108)** | **+3.80% Improvement** |
| **Equipment Recall** | 100.00% (6/6) | **100.00% (6/6)** | **0.00% (Preserved)** |
| **Equipment Precision** | 62.50% (6/9) | **100.00% (6/6)** | **+37.50% Improvement** |
| **PSV Recall** | 100.00% (2/2) | **100.00% (2/2)** | **0.00% (Preserved)** |
| **PSV Precision** | 100.00% (2/2) | **100.00% (2/2)** | **0.00% (Preserved)** |
| **Instrument Recall** | 100.00% (14/14) | **100.00% (14/14)** | **0.00% (Preserved)** |
| **Instrument Precision** | 73.68% (14/19) | **100.00% (14/14)** | **+26.32% Improvement** |
| **Valve Recall** | 97.30% (36/37) | **97.30% (36/37)** | **0.00% (Preserved)** |
| **Valve Precision** | 70.59% (36/51) | **70.59% (36/51)** | **0.00% (Preserved)** |
| **Line Recall** | 100.00% (29/29) | **100.00% (29/29)** | **0.00% (Preserved)** |
| **Line Precision** | 85.29% (29/34) | **85.29% (29/34)** | **0.00% (Preserved)** |
| **Generic Components** | 12 duplicates | **0** | **-100% (Eliminated)** |
| **Spurious Fallback Edges** | 22 (`MONITORS`) | **0** | **-100% (Eliminated)** |
| **Total Relationships** | 88 (untyped) | **66 (domain-typed)** | **Auditable Evidence** |
---
## 3. Two-Drawing Regression Summary
* **Drawing A Recall:** 100.00% (104 / 104 GT objects matched). Zero false negatives.
* **Drawing B Recall:** 98.86% (87 / 88 GT objects matched). Only 1 missed object: `26GB9178` (which does not exist in OCR perception).
* **Drawing B Instrument Precision:** Increased from 73.68% to **100.00%** (14 / 14, 0 false positives).
* **Drawing B Equipment Precision:** Increased from 62.50% to **100.00%** (6 / 6, 0 false positives).
* **Generic Component Duplication:** Completely reduced to **0** on both drawings.
* **Unit Tests:** 60 / 60 passed in 9.39s.
* **End-to-End Pipeline:** All verification checks passed in `verify_pipeline.py`.