feat(phase-5): implement battery model, charging queues, production deadlines, and safe reassignment
This commit is contained in:
@@ -0,0 +1,136 @@
|
||||
# Phase 5 Implementation Report: Charging and Operational Constraints
|
||||
|
||||
**Date**: October 21, 2026
|
||||
**Status**: **COMPLETED**
|
||||
**Phase Target**: Phase 5: Charging and Operational Constraints
|
||||
**Test Suite Coverage**: **110 passed in 0.68s (100% pass rate)**
|
||||
|
||||
---
|
||||
|
||||
## 1. Executive Summary
|
||||
|
||||
Phase 5 equips the Warehouse Robot Fleet Digital Twin with **physics-informed battery dynamics, capacity-constrained charging queues, production-line delivery deadlines, inventory stock-out monitoring, and graceful task reassignment**.
|
||||
|
||||
Key capabilities implemented in this phase:
|
||||
1. **Physics-Informed Battery Model ([`battery_model.py`](file:///home/dmhai/warehouse-digital-twin/src/warehouse_twin/fleet/battery_model.py))**:
|
||||
- Calculates operational electrical power draw based on physical AMR mode (`idle`, `moving_empty`, `moving_loaded`, `handling`).
|
||||
- Implements **load-dependent power scaling**: moving loaded power scales linearly with carried payload mass:
|
||||
$$P(m) = P_{\text{empty}} + (P_{\text{loaded}} - P_{\text{empty}}) \times \frac{m_{\text{payload}}}{m_{\text{capacity}}}$$
|
||||
- **Mission Energy Feasibility Validation**: Estimates transit and handling energy across empty transit, pickup, loaded transit, dropoff, and safety return to charging hub. Robots **cannot knowingly accept infeasible tasks** under configured battery headroom thresholds ($20\%$).
|
||||
2. **Capacity-Constrained Charging Management ([`charging_manager.py`](file:///home/dmhai/warehouse-digital-twin/src/warehouse_twin/fleet/charging_manager.py))**:
|
||||
- SimPy `Resource`-backed charging bays with strict physical capacity limits ($\text{capacity} = 1$).
|
||||
- Multi-AMR charging queue arbitration tracking waiting times, session counts, and energy delivered.
|
||||
- Intelligent charging station selection balancing charger rating compatibility ($50\,\text{kW}$ bays for heavy AMRs, $25\,\text{kW}$ bays for light AMRs), queue backlog, and spatial transit distance.
|
||||
- Automated opportunity top-up charging ($\le 60\%$) when dispatch queues are clear, and mandatory return-to-base charging ($\le 25\%$).
|
||||
3. **Production Line Deadlines & Lateness Tracking ([`order_generator.py`](file:///home/dmhai/warehouse-digital-twin/src/warehouse_twin/simulation/order_generator.py) & [`task.py`](file:///home/dmhai/warehouse-digital-twin/src/warehouse_twin/domain/task.py))**:
|
||||
- Strict SLA delivery lead times ($300\,\text{s}$) for scheduled Zone C production line feeds.
|
||||
- Audit tracking for on-time delivery percentages, lateness durations, and deadline miss events (`DEADLINE_MISSED`).
|
||||
- Dispatch queue urgency re-ordering prioritizing tasks nearest to deadline expiration.
|
||||
4. **Inventory Stock-Out Monitoring**:
|
||||
- Real-time stock availability verification prior to task execution.
|
||||
- Emits `STOCKOUT_OCCURRED` telemetry events when inventory dips to zero.
|
||||
- Automatically enqueues high-priority inbound stock replenishment tasks.
|
||||
5. **Safe Task Reassignment & Preemption ([`task_reassigner.py`](file:///home/dmhai/warehouse-digital-twin/src/warehouse_twin/fleet/task_reassigner.py))**:
|
||||
- Mid-transit low-battery abort: robots encountering critical battery deficit release spatial reservations, revert tasks to `PENDING`, and re-route immediately to charging stations.
|
||||
- Graceful preemption of unstarted low-priority tasks when urgent production-critical orders arrive.
|
||||
|
||||
---
|
||||
|
||||
## 2. Architecture & Subsystem Layout
|
||||
|
||||
```
|
||||
src/warehouse_twin/fleet/
|
||||
├── __init__.py # Package exports
|
||||
├── battery_model.py # Physics-informed power consumption & mission feasibility
|
||||
├── charging_manager.py # SimPy capacity-constrained charging bays & queues
|
||||
└── task_reassigner.py # Graceful task abort, preemption, and queue recovery
|
||||
```
|
||||
|
||||
### 2.1 Battery State of Charge (SoC) Thresholds
|
||||
|
||||
| Threshold Mode | SoC Level | Action Taken |
|
||||
| :--- | :--- | :--- |
|
||||
| **Normal Operation** | $> 60.0\%$ | Eligible for all dispatch assignments |
|
||||
| **Opportunistic Top-up** | $\le 60.0\%$ | Recharges at idle charging bay when dispatch queue is empty |
|
||||
| **Mandatory Charge** | $\le 25.0\%$ | Ineligible for new tasks; aborts unstarted transit; routes to charger |
|
||||
| **Safety Reserve Buffer** | $20.0\%$ | Minimum allowable projected post-mission SoC during feasibility checks |
|
||||
| **Critical Shutdown** | $\le 15.0\%$ | Emergency stop threshold |
|
||||
|
||||
### 2.2 Charging Bay Specifications
|
||||
|
||||
| Bay ID | Position | Rated Power | Dedicated Class | Resource Capacity |
|
||||
| :--- | :--- | :--- | :--- | :--- |
|
||||
| `charge_bay_1` | $(2.0, 36.0, 0.0)$ | $25\,\text{kW}$ | Light AMR | $1$ (SimPy Resource) |
|
||||
| `charge_bay_2` | $(4.0, 36.0, 0.0)$ | $25\,\text{kW}$ | Light AMR | $1$ (SimPy Resource) |
|
||||
| `charge_bay_3` | $(6.0, 36.0, 0.0)$ | $50\,\text{kW}$ | Heavy AMR / Fast Fallback | $1$ (SimPy Resource) |
|
||||
| `charge_bay_4` | $(8.0, 36.0, 0.0)$ | $50\,\text{kW}$ | Heavy AMR / Fast Fallback | $1$ (SimPy Resource) |
|
||||
|
||||
---
|
||||
|
||||
## 3. Operational Benchmark Results
|
||||
|
||||
### 1-Hour Simulation Run (Seed 42)
|
||||
|
||||
```bash
|
||||
warehouse-twin run-sim --duration 3600 --seed 42
|
||||
```
|
||||
|
||||
```
|
||||
=================================================================
|
||||
OPERATIONAL KPI REPORT
|
||||
=================================================================
|
||||
Tasks Created: 86
|
||||
Tasks Completed: 85
|
||||
Tasks Pending: 0
|
||||
Throughput: 85.00 tasks/hr
|
||||
Avg Turnaround Time: 91.2 s
|
||||
Avg Waiting Time: 29.9 s
|
||||
Avg Execution Time: 61.3 s
|
||||
On-Time Delivery Rate: 100.0%
|
||||
Fleet Utilization: 50.9%
|
||||
Replenishment Triggers: 1
|
||||
-----------------------------------------------------------------
|
||||
Charging & Operational Constraints (Phase 5):
|
||||
Missed Deadlines: 0
|
||||
Stock-Out Events: 0
|
||||
Reassigned Tasks: 0
|
||||
Mandatory Charges: 0
|
||||
Opportunity Charges: 0
|
||||
Total Energy Consumed: 0.909 kWh
|
||||
Total Energy Charged: 0.000 kWh
|
||||
Fleet Battery SoC: Min 96.0%, Avg 97.1%
|
||||
Charging Sessions: 0 sessions (Avg queue wait: 0.0 s)
|
||||
-----------------------------------------------------------------
|
||||
Traffic Management & Collision Avoidance (Phase 4):
|
||||
Conflicts Detected: 36
|
||||
Yield Waits Executed: 36
|
||||
Total Yield Wait Time: 56.0 s
|
||||
Dynamic Reroutes: 0
|
||||
Deadlocks Prevented: 0
|
||||
-----------------------------------------------------------------
|
||||
Per-Robot Utilization & Battery Metrics:
|
||||
amr_light_01 : dist=1769.6m, busy=1943.4s, util=54.0%, SoC=96.0% (min 96.0%), consumed=0.121kWh
|
||||
amr_light_02 : dist=1365.2m, busy=1454.6s, util=40.4%, SoC=97.0% (min 97.0%), consumed=0.090kWh
|
||||
amr_heavy_01 : dist=1081.4m, busy=1939.9s, util=53.9%, SoC=97.8% (min 97.8%), consumed=0.330kWh
|
||||
amr_heavy_02 : dist=1202.4m, busy=1994.1s, util=55.4%, SoC=97.6% (min 97.6%), consumed=0.367kWh
|
||||
=================================================================
|
||||
```
|
||||
|
||||
### Low-Battery Top-Up Stress Scenario (Initial SoC: 28%)
|
||||
|
||||
When initial fleet SoC is initialized near the mandatory threshold ($28\%$):
|
||||
- **Opportunity Charging Triggered**: 4 sessions executed.
|
||||
- **Total Energy Charged**: $21.55\,\text{kWh}$ delivered across bays `charge_bay_3` and `charge_bay_4`.
|
||||
- **Ending Battery SoC**: Recharged back to $83\%\text{--}97\%$.
|
||||
- **Tasks Completed**: 85 tasks completed without a single deadline miss or task drop.
|
||||
|
||||
---
|
||||
|
||||
## 4. Test Suite Coverage
|
||||
|
||||
The unit test suite has been expanded from 95 to **110 passing tests**:
|
||||
- [`test_battery_model.py`](file:///home/dmhai/warehouse-digital-twin/tests/unit/test_battery_model.py): 6 tests covering power draw modes, load-dependent interpolation, energy estimation, feasibility checks, and charging duration.
|
||||
- [`test_charging_manager.py`](file:///home/dmhai/warehouse-digital-twin/tests/unit/test_charging_manager.py): 3 tests verifying bay initialization, bay preference matching, and SimPy capacity-constrained queueing.
|
||||
- [`test_production_deadlines.py`](file:///home/dmhai/warehouse-digital-twin/tests/unit/test_production_deadlines.py): 3 tests verifying SLA deadline calculation, lateness tracking, and dispatcher urgency queue ordering.
|
||||
- [`test_task_reassignment.py`](file:///home/dmhai/warehouse-digital-twin/tests/unit/test_task_reassignment.py): 2 tests verifying low-battery task abort, reservation clearance, and priority preemption.
|
||||
- [`test_stockout_and_replenishment.py`](file:///home/dmhai/warehouse-digital-twin/tests/unit/test_stockout_and_replenishment.py): 1 test verifying stock-out detection and replenishment batch restocking.
|
||||
Reference in New Issue