feat(phase-5): implement battery model, charging queues, production deadlines, and safe reassignment

This commit is contained in:
2026-10-21 11:36:48 +05:30
parent 56806079a9
commit 1e50508f53
20 changed files with 2215 additions and 99 deletions
@@ -0,0 +1,136 @@
# Phase 5 Implementation Report: Charging and Operational Constraints
**Date**: October 21, 2026
**Status**: **COMPLETED**
**Phase Target**: Phase 5: Charging and Operational Constraints
**Test Suite Coverage**: **110 passed in 0.68s (100% pass rate)**
---
## 1. Executive Summary
Phase 5 equips the Warehouse Robot Fleet Digital Twin with **physics-informed battery dynamics, capacity-constrained charging queues, production-line delivery deadlines, inventory stock-out monitoring, and graceful task reassignment**.
Key capabilities implemented in this phase:
1. **Physics-Informed Battery Model ([`battery_model.py`](file:///home/dmhai/warehouse-digital-twin/src/warehouse_twin/fleet/battery_model.py))**:
- Calculates operational electrical power draw based on physical AMR mode (`idle`, `moving_empty`, `moving_loaded`, `handling`).
- Implements **load-dependent power scaling**: moving loaded power scales linearly with carried payload mass:
$$P(m) = P_{\text{empty}} + (P_{\text{loaded}} - P_{\text{empty}}) \times \frac{m_{\text{payload}}}{m_{\text{capacity}}}$$
- **Mission Energy Feasibility Validation**: Estimates transit and handling energy across empty transit, pickup, loaded transit, dropoff, and safety return to charging hub. Robots **cannot knowingly accept infeasible tasks** under configured battery headroom thresholds ($20\%$).
2. **Capacity-Constrained Charging Management ([`charging_manager.py`](file:///home/dmhai/warehouse-digital-twin/src/warehouse_twin/fleet/charging_manager.py))**:
- SimPy `Resource`-backed charging bays with strict physical capacity limits ($\text{capacity} = 1$).
- Multi-AMR charging queue arbitration tracking waiting times, session counts, and energy delivered.
- Intelligent charging station selection balancing charger rating compatibility ($50\,\text{kW}$ bays for heavy AMRs, $25\,\text{kW}$ bays for light AMRs), queue backlog, and spatial transit distance.
- Automated opportunity top-up charging ($\le 60\%$) when dispatch queues are clear, and mandatory return-to-base charging ($\le 25\%$).
3. **Production Line Deadlines & Lateness Tracking ([`order_generator.py`](file:///home/dmhai/warehouse-digital-twin/src/warehouse_twin/simulation/order_generator.py) & [`task.py`](file:///home/dmhai/warehouse-digital-twin/src/warehouse_twin/domain/task.py))**:
- Strict SLA delivery lead times ($300\,\text{s}$) for scheduled Zone C production line feeds.
- Audit tracking for on-time delivery percentages, lateness durations, and deadline miss events (`DEADLINE_MISSED`).
- Dispatch queue urgency re-ordering prioritizing tasks nearest to deadline expiration.
4. **Inventory Stock-Out Monitoring**:
- Real-time stock availability verification prior to task execution.
- Emits `STOCKOUT_OCCURRED` telemetry events when inventory dips to zero.
- Automatically enqueues high-priority inbound stock replenishment tasks.
5. **Safe Task Reassignment & Preemption ([`task_reassigner.py`](file:///home/dmhai/warehouse-digital-twin/src/warehouse_twin/fleet/task_reassigner.py))**:
- Mid-transit low-battery abort: robots encountering critical battery deficit release spatial reservations, revert tasks to `PENDING`, and re-route immediately to charging stations.
- Graceful preemption of unstarted low-priority tasks when urgent production-critical orders arrive.
---
## 2. Architecture & Subsystem Layout
```
src/warehouse_twin/fleet/
├── __init__.py # Package exports
├── battery_model.py # Physics-informed power consumption & mission feasibility
├── charging_manager.py # SimPy capacity-constrained charging bays & queues
└── task_reassigner.py # Graceful task abort, preemption, and queue recovery
```
### 2.1 Battery State of Charge (SoC) Thresholds
| Threshold Mode | SoC Level | Action Taken |
| :--- | :--- | :--- |
| **Normal Operation** | $> 60.0\%$ | Eligible for all dispatch assignments |
| **Opportunistic Top-up** | $\le 60.0\%$ | Recharges at idle charging bay when dispatch queue is empty |
| **Mandatory Charge** | $\le 25.0\%$ | Ineligible for new tasks; aborts unstarted transit; routes to charger |
| **Safety Reserve Buffer** | $20.0\%$ | Minimum allowable projected post-mission SoC during feasibility checks |
| **Critical Shutdown** | $\le 15.0\%$ | Emergency stop threshold |
### 2.2 Charging Bay Specifications
| Bay ID | Position | Rated Power | Dedicated Class | Resource Capacity |
| :--- | :--- | :--- | :--- | :--- |
| `charge_bay_1` | $(2.0, 36.0, 0.0)$ | $25\,\text{kW}$ | Light AMR | $1$ (SimPy Resource) |
| `charge_bay_2` | $(4.0, 36.0, 0.0)$ | $25\,\text{kW}$ | Light AMR | $1$ (SimPy Resource) |
| `charge_bay_3` | $(6.0, 36.0, 0.0)$ | $50\,\text{kW}$ | Heavy AMR / Fast Fallback | $1$ (SimPy Resource) |
| `charge_bay_4` | $(8.0, 36.0, 0.0)$ | $50\,\text{kW}$ | Heavy AMR / Fast Fallback | $1$ (SimPy Resource) |
---
## 3. Operational Benchmark Results
### 1-Hour Simulation Run (Seed 42)
```bash
warehouse-twin run-sim --duration 3600 --seed 42
```
```
=================================================================
OPERATIONAL KPI REPORT
=================================================================
Tasks Created: 86
Tasks Completed: 85
Tasks Pending: 0
Throughput: 85.00 tasks/hr
Avg Turnaround Time: 91.2 s
Avg Waiting Time: 29.9 s
Avg Execution Time: 61.3 s
On-Time Delivery Rate: 100.0%
Fleet Utilization: 50.9%
Replenishment Triggers: 1
-----------------------------------------------------------------
Charging & Operational Constraints (Phase 5):
Missed Deadlines: 0
Stock-Out Events: 0
Reassigned Tasks: 0
Mandatory Charges: 0
Opportunity Charges: 0
Total Energy Consumed: 0.909 kWh
Total Energy Charged: 0.000 kWh
Fleet Battery SoC: Min 96.0%, Avg 97.1%
Charging Sessions: 0 sessions (Avg queue wait: 0.0 s)
-----------------------------------------------------------------
Traffic Management & Collision Avoidance (Phase 4):
Conflicts Detected: 36
Yield Waits Executed: 36
Total Yield Wait Time: 56.0 s
Dynamic Reroutes: 0
Deadlocks Prevented: 0
-----------------------------------------------------------------
Per-Robot Utilization & Battery Metrics:
amr_light_01 : dist=1769.6m, busy=1943.4s, util=54.0%, SoC=96.0% (min 96.0%), consumed=0.121kWh
amr_light_02 : dist=1365.2m, busy=1454.6s, util=40.4%, SoC=97.0% (min 97.0%), consumed=0.090kWh
amr_heavy_01 : dist=1081.4m, busy=1939.9s, util=53.9%, SoC=97.8% (min 97.8%), consumed=0.330kWh
amr_heavy_02 : dist=1202.4m, busy=1994.1s, util=55.4%, SoC=97.6% (min 97.6%), consumed=0.367kWh
=================================================================
```
### Low-Battery Top-Up Stress Scenario (Initial SoC: 28%)
When initial fleet SoC is initialized near the mandatory threshold ($28\%$):
- **Opportunity Charging Triggered**: 4 sessions executed.
- **Total Energy Charged**: $21.55\,\text{kWh}$ delivered across bays `charge_bay_3` and `charge_bay_4`.
- **Ending Battery SoC**: Recharged back to $83\%\text{--}97\%$.
- **Tasks Completed**: 85 tasks completed without a single deadline miss or task drop.
---
## 4. Test Suite Coverage
The unit test suite has been expanded from 95 to **110 passing tests**:
- [`test_battery_model.py`](file:///home/dmhai/warehouse-digital-twin/tests/unit/test_battery_model.py): 6 tests covering power draw modes, load-dependent interpolation, energy estimation, feasibility checks, and charging duration.
- [`test_charging_manager.py`](file:///home/dmhai/warehouse-digital-twin/tests/unit/test_charging_manager.py): 3 tests verifying bay initialization, bay preference matching, and SimPy capacity-constrained queueing.
- [`test_production_deadlines.py`](file:///home/dmhai/warehouse-digital-twin/tests/unit/test_production_deadlines.py): 3 tests verifying SLA deadline calculation, lateness tracking, and dispatcher urgency queue ordering.
- [`test_task_reassignment.py`](file:///home/dmhai/warehouse-digital-twin/tests/unit/test_task_reassignment.py): 2 tests verifying low-battery task abort, reservation clearance, and priority preemption.
- [`test_stockout_and_replenishment.py`](file:///home/dmhai/warehouse-digital-twin/tests/unit/test_stockout_and_replenishment.py): 1 test verifying stock-out detection and replenishment batch restocking.