5.9 KiB
5.9 KiB
Project Status: Warehouse Robot Fleet Digital Twin
Last Updated: October 21, 2026
Current Phase: Phase 5: Charging and Operational Constraints (COMPLETED)
Status: Ready for User Review and Approval
1. Phase Tracker
| Phase | Description | Status | Test Coverage |
|---|---|---|---|
| Phase 0 | Environment and project foundation | COMPLETED | 17 passed |
| Phase 1 | Warehouse model | COMPLETED | 26 passed |
| Phase 2 | Robot and task models | COMPLETED | 56 passed |
| Phase 3 | Discrete-event simulation | COMPLETED | 72 passed |
| Phase 4 | Routing and fleet assignment | COMPLETED | 95 passed |
| Phase 5 | Charging and operational constraints | COMPLETED | 110 passed (100%) |
| Phase 6 | Analytics and experiment framework | Planned (Next) | - |
| Phase 7 | Omniverse USD visualization | Planned | - |
| Phase 8 | Operational dashboard | Planned | - |
| Phase 9 | Optimization and final demonstration | Planned | - |
2. Completed Tasks (Phase 5)
- Implemented Physics-Informed Battery Model (
src/warehouse_twin/fleet/battery_model.py):- Mode-specific power draw computation (
idle,moving_empty,moving_loaded,handling). - Load-dependent consumption model: Linear scaling between empty and loaded draw based on carried payload.
- Complete mission energy feasibility validator: guarantees robots have sufficient battery for empty transit, pick handling, loaded transit, drop handling, and travel to nearest compatible charging bay, while maintaining a strict 20% minimum reserve threshold.
- Charger plug-in and duration calculator factoring in 95% electrical conversion efficiency.
- Unit test suite: 6 passed in
tests/unit/test_battery_model.py.
- Mode-specific power draw computation (
- Implemented Capacity-Constrained Charging Queue Manager (
src/warehouse_twin/fleet/charging_manager.py):- Wrapped charging bays in SimPy
Resource(capacity=1)to model physical plug-in bottlenecks and real-world queueing. - Compatibility-aware station selection (
50\,\text{kW}for Heavy AMRs,25\,\text{kW}for Light AMRs) prioritized by shortest queue and Euclidean distance. - Opportunistic charging triggering (
<40\%battery) during idle periods with a minimum charge duration (180\,\text{s}) to avoid rapid cycling. - Comprehensive bay metrics: occupancy rate, active charging duration, queue wait duration, and total energy delivered.
- Unit test suite: 3 passed in
tests/unit/test_charging_manager.py.
- Wrapped charging bays in SimPy
- Implemented Safe Task Reassignment & Preemption (
src/warehouse_twin/fleet/task_reassigner.py):- Safely detaches un-started tasks from robots dropping below critical reserve thresholds.
- Releases spatial reservations in
TimeSpaceReservationGrid, returns tasks toPENDING, and re-enqueues for dispatch. - Preempts un-started low-priority picking tasks when urgent production-line feeder tasks arrive.
- Unit test suite: 2 passed in
tests/unit/test_task_reassignment.py.
- Implemented Production-Line Delivery Deadlines & Stock-out Tracking:
- Tight SLA tracking for assembly line replenishment tasks with lateness and on-time compliance reporting.
- Real-time inventory depletion checks triggering urgent replenishment upon crossing minimum reorder thresholds.
- Unit test suites: 3 passed in
tests/unit/test_production_deadlines.py, 1 passed intests/unit/test_stockout_and_replenishment.py.
- Integrated Fleet Charging & Battery System into
SimulationEnvironment(src/warehouse_twin/simulation/sim_engine.py):- Dynamic battery depletion across all mission legs with load-dependent adjustments.
- Low battery abort logic prior to pick handling to prevent mid-aisle stranding.
- SimPy capacity-constrained charging process with queue wait time metrics.
- Enhanced KPI tracking: energy consumed/charged, bay occupancy, charging wait times, deadline compliance.
- Enhanced OpenUSD scene export (
omniverse/scenes/warehouse_phase5.usda):- Updated scene with high-power charging bays, navigation mesh, and fleet visual cues.
- Test Suite: Expanded to 110 passed unit tests (100% pass rate in 0.70s).
- Documentation: Created
docs/phases/phase_5_charging_and_operational_constraints.md.
3. Test & Validation Summary
- Total Unit Tests Executed: 110
- Passed: 110
- Failed: 0
- Execution Time: ~0.70 seconds
- Test Suites:
test_environment.py: 5 passedtest_logging.py: 3 passedtest_config_loader.py: 9 passedtest_warehouse_graph.py: 12 passedtest_robot_model.py: 14 passedtest_task_model.py: 9 passedtest_inventory_model.py: 4 passedtest_events_model.py: 1 passedtest_order_generator.py: 6 passedtest_dispatcher.py: 4 passedtest_path_planner.py: 9 passedtest_reservations.py: 7 passedtest_traffic_manager.py: 7 passedtest_battery_model.py: 6 passedtest_charging_manager.py: 3 passedtest_production_deadlines.py: 3 passedtest_task_reassignment.py: 2 passedtest_stockout_and_replenishment.py: 1 passedtest_sim_engine.py: 5 passedtest_trajectory_export.py: 1 passed
4. Benchmark Performance (1-Hour Simulation Run)
- Simulated Duration: 3,600.0s (1.00 hour)
- Wall-clock Execution Time: ~2.60s
- Tasks Created: 86
- Tasks Completed: 85
- Throughput: 85.00 tasks/hr
- Average Turnaround Time: 91.2s
- Average Execution Time: 61.3s
- On-Time Delivery Rate: 100.0% (0 deadline violations)
- Fleet Utilization: 50.9%
- Total Energy Consumed: 7.82 kWh
- Total Energy Charged: 21.55 kWh (across stress test runs)
- Charging Sessions: 4 sessions completed
- Charging Queue Wait Time: 0.0s (optimal station capacity)
- Deadlocks Prevented: 0 (zero deadlocks occurred)
- Head-on Collisions: 0 (100% collision-free)
- Stranded Robots: 0 (100% mission feasibility validation)