Files
Warehouse-Digital-Twin-and-…/PROJECT_STATUS.md
T

5.9 KiB

Project Status: Warehouse Robot Fleet Digital Twin

Last Updated: October 21, 2026
Current Phase: Phase 5: Charging and Operational Constraints (COMPLETED)
Status: Ready for User Review and Approval


1. Phase Tracker

Phase Description Status Test Coverage
Phase 0 Environment and project foundation COMPLETED 17 passed
Phase 1 Warehouse model COMPLETED 26 passed
Phase 2 Robot and task models COMPLETED 56 passed
Phase 3 Discrete-event simulation COMPLETED 72 passed
Phase 4 Routing and fleet assignment COMPLETED 95 passed
Phase 5 Charging and operational constraints COMPLETED 110 passed (100%)
Phase 6 Analytics and experiment framework Planned (Next) -
Phase 7 Omniverse USD visualization Planned -
Phase 8 Operational dashboard Planned -
Phase 9 Optimization and final demonstration Planned -

2. Completed Tasks (Phase 5)

  • Implemented Physics-Informed Battery Model (src/warehouse_twin/fleet/battery_model.py):
    • Mode-specific power draw computation (idle, moving_empty, moving_loaded, handling).
    • Load-dependent consumption model: Linear scaling between empty and loaded draw based on carried payload.
    • Complete mission energy feasibility validator: guarantees robots have sufficient battery for empty transit, pick handling, loaded transit, drop handling, and travel to nearest compatible charging bay, while maintaining a strict 20% minimum reserve threshold.
    • Charger plug-in and duration calculator factoring in 95% electrical conversion efficiency.
    • Unit test suite: 6 passed in tests/unit/test_battery_model.py.
  • Implemented Capacity-Constrained Charging Queue Manager (src/warehouse_twin/fleet/charging_manager.py):
    • Wrapped charging bays in SimPy Resource(capacity=1) to model physical plug-in bottlenecks and real-world queueing.
    • Compatibility-aware station selection (50\,\text{kW} for Heavy AMRs, 25\,\text{kW} for Light AMRs) prioritized by shortest queue and Euclidean distance.
    • Opportunistic charging triggering (<40\% battery) during idle periods with a minimum charge duration (180\,\text{s}) to avoid rapid cycling.
    • Comprehensive bay metrics: occupancy rate, active charging duration, queue wait duration, and total energy delivered.
    • Unit test suite: 3 passed in tests/unit/test_charging_manager.py.
  • Implemented Safe Task Reassignment & Preemption (src/warehouse_twin/fleet/task_reassigner.py):
    • Safely detaches un-started tasks from robots dropping below critical reserve thresholds.
    • Releases spatial reservations in TimeSpaceReservationGrid, returns tasks to PENDING, and re-enqueues for dispatch.
    • Preempts un-started low-priority picking tasks when urgent production-line feeder tasks arrive.
    • Unit test suite: 2 passed in tests/unit/test_task_reassignment.py.
  • Implemented Production-Line Delivery Deadlines & Stock-out Tracking:
    • Tight SLA tracking for assembly line replenishment tasks with lateness and on-time compliance reporting.
    • Real-time inventory depletion checks triggering urgent replenishment upon crossing minimum reorder thresholds.
    • Unit test suites: 3 passed in tests/unit/test_production_deadlines.py, 1 passed in tests/unit/test_stockout_and_replenishment.py.
  • Integrated Fleet Charging & Battery System into SimulationEnvironment (src/warehouse_twin/simulation/sim_engine.py):
    • Dynamic battery depletion across all mission legs with load-dependent adjustments.
    • Low battery abort logic prior to pick handling to prevent mid-aisle stranding.
    • SimPy capacity-constrained charging process with queue wait time metrics.
    • Enhanced KPI tracking: energy consumed/charged, bay occupancy, charging wait times, deadline compliance.
  • Enhanced OpenUSD scene export (omniverse/scenes/warehouse_phase5.usda):
    • Updated scene with high-power charging bays, navigation mesh, and fleet visual cues.
  • Test Suite: Expanded to 110 passed unit tests (100% pass rate in 0.70s).
  • Documentation: Created docs/phases/phase_5_charging_and_operational_constraints.md.

3. Test & Validation Summary

  • Total Unit Tests Executed: 110
  • Passed: 110
  • Failed: 0
  • Execution Time: ~0.70 seconds
  • Test Suites:
    • test_environment.py: 5 passed
    • test_logging.py: 3 passed
    • test_config_loader.py: 9 passed
    • test_warehouse_graph.py: 12 passed
    • test_robot_model.py: 14 passed
    • test_task_model.py: 9 passed
    • test_inventory_model.py: 4 passed
    • test_events_model.py: 1 passed
    • test_order_generator.py: 6 passed
    • test_dispatcher.py: 4 passed
    • test_path_planner.py: 9 passed
    • test_reservations.py: 7 passed
    • test_traffic_manager.py: 7 passed
    • test_battery_model.py: 6 passed
    • test_charging_manager.py: 3 passed
    • test_production_deadlines.py: 3 passed
    • test_task_reassignment.py: 2 passed
    • test_stockout_and_replenishment.py: 1 passed
    • test_sim_engine.py: 5 passed
    • test_trajectory_export.py: 1 passed

4. Benchmark Performance (1-Hour Simulation Run)

  • Simulated Duration: 3,600.0s (1.00 hour)
  • Wall-clock Execution Time: ~2.60s
  • Tasks Created: 86
  • Tasks Completed: 85
  • Throughput: 85.00 tasks/hr
  • Average Turnaround Time: 91.2s
  • Average Execution Time: 61.3s
  • On-Time Delivery Rate: 100.0% (0 deadline violations)
  • Fleet Utilization: 50.9%
  • Total Energy Consumed: 7.82 kWh
  • Total Energy Charged: 21.55 kWh (across stress test runs)
  • Charging Sessions: 4 sessions completed
  • Charging Queue Wait Time: 0.0s (optimal station capacity)
  • Deadlocks Prevented: 0 (zero deadlocks occurred)
  • Head-on Collisions: 0 (100% collision-free)
  • Stranded Robots: 0 (100% mission feasibility validation)